Search

Find a vulnerability

Search criteria ⓘ Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    9093 vulnerabilities

    CVE-2026-4642 (GCVE-0-2026-4642)

    Vulnerability from cvelistv5 – Published: 2026-11-27 14:15 – Updated: 2026-11-27 14:15
    VLAI
    Title
    Undocumented factory accounts
    Summary
    Incorrect Authorization vulnerability in ABB Relion Protection Relays REX610, ABB Relion Protection Relays RE_611 IEC/CN, ABB Relion Protection Relays RBX615, ABB Relion Protection Relays REF615 ANSI, ABB Relion Protection Relays REF615R ANSI, ABB Relion Protection Relays RER615, ABB Relion Protection Relays REC615, ABB Relion Protection Relays REX615, ABB Relion Protection Relays 615 series IEC, ABB Relion Protection Relays 615 series CN, ABB Relion Protection Relays 615 series ANSI, ABB Relion Protection Relays RER620 ANSI, ABB Relion Protection Relays 620 series ANSI, ABB Relion Protection Relays 620 series IEC/CN, and ABB Substation Merging Unit SMU615. This issue affects Relion Protection Relays REX610: 1.0, 1.1, and 1.2; Relion Protection Relays RE_611 IEC/CN: 1.0 and 2.0; Relion Protection Relays RBX615: 1.0 and 2.0; Relion Protection Relays REF615 ANSI: 4.1; Relion Protection Relays REF615R ANSI: 4.0 and 4.0 FP1; Relion Protection Relays RER615: 1.0, 1.1, and 2.0; Relion Protection Relays REC615: 1.0, 1.1, and 2.0; Relion Protection Relays REX615: PCL1 (6.0); Relion Protection Relays 615 series IEC: 3.1, 4.0, 4.0 FP1, 5.0, and 5.0 FP1; Relion Protection Relays 615 series CN: 3.1, 4.1, and 5.0 FP1; Relion Protection Relays 615 series ANSI: 4.0, 4.0 FP1, 4.0 FP2, and 5.0 FP1; Relion Protection Relays RER620 ANSI: 1.1, 1.2, and 1.3; Relion Protection Relays 620 series ANSI: 2.0 and 2.0 FP1; Relion Protection Relays 620 series IEC/CN: 2.0 and 2.0 FP1; Substation Merging Unit SMU615: 1.0.
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    ABB CNA under the icscert root
    CNA scorecard C 68/100 over 20 records in the last 180 days details
    Impacted products
    Vendor Product Version
    ABB Relion Protection Relays REX610 Affected: 1.0 (custom)
    Affected: 1.1 (custom)
    Affected: 1.2 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays RE_611 IEC/CN Affected: 1.0 (custom)
    Affected: 2.0 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays RBX615 Affected: 1.0 (custom)
    Affected: 2.0 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays REF615 ANSI Affected: 4.1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays REF615R ANSI Affected: 4.0 (custom)
    Affected: 4.0 FP1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays RER615 Affected: 1.0 (custom)
    Affected: 1.1 (custom)
    Affected: 2.0 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays REC615 Affected: 1.0 (custom)
    Affected: 1.1 (custom)
    Affected: 2.0 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays REX615 Affected: PCL1 (6.0) (custom)
    Create a notification for this product.
    ABB Relion Protection Relays 615 series IEC Affected: 3.1 (custom)
    Affected: 4.0 (custom)
    Affected: 4.0 FP1 (custom)
    Affected: 5.0 (custom)
    Affected: 5.0 FP1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays 615 series CN Affected: 3.1 (custom)
    Affected: 4.1 (custom)
    Affected: 5.0 FP1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays 615 series ANSI Affected: 4.0 (custom)
    Affected: 4.0 FP1 (custom)
    Affected: 4.0 FP2 (custom)
    Affected: 5.0 FP1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays RER620 ANSI Affected: 1.1 (custom)
    Affected: 1.2 (custom)
    Affected: 1.3 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays 620 series ANSI Affected: 2.0 (custom)
    Affected: 2.0 FP1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays 620 series IEC/CN Affected: 2.0 (custom)
    Affected: 2.0 FP1 (custom)
    Create a notification for this product.
    ABB Substation Merging Unit SMU615 Affected: 1.0 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays REX610",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays RE_611 IEC/CN",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays RBX615",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays REF615 ANSI",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays REF615R ANSI",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "4.0 FP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays RER615",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays REC615",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays REX615",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "PCL1 (6.0)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays 615 series IEC",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "4.0 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "5.0 FP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays 615 series CN",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "4.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "5.0 FP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays 615 series ANSI",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "4.0 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "4.0 FP2",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "5.0 FP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays RER620 ANSI",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays 620 series ANSI",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0 FP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays 620 series IEC/CN",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0 FP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Substation Merging Unit SMU615",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Incorrect Authorization vulnerability in ABB Relion Protection Relays REX610, ABB Relion Protection Relays RE_611 IEC/CN, ABB Relion Protection Relays RBX615, ABB Relion Protection Relays REF615 ANSI, ABB Relion Protection Relays REF615R ANSI, ABB Relion Protection Relays RER615, ABB Relion Protection Relays REC615, ABB Relion Protection Relays REX615, ABB Relion Protection Relays 615 series IEC, ABB Relion Protection Relays 615 series CN, ABB Relion Protection Relays 615 series ANSI, ABB Relion Protection Relays RER620 ANSI, ABB Relion Protection Relays 620 series ANSI, ABB Relion Protection Relays 620 series IEC/CN, and ABB Substation Merging Unit SMU615.\u003cp\u003eThis issue affects Relion Protection Relays REX610: 1.0, 1.1, and 1.2; Relion Protection Relays RE_611 IEC/CN: 1.0 and 2.0; Relion Protection Relays RBX615: 1.0 and 2.0; Relion Protection Relays REF615 ANSI: 4.1; Relion Protection Relays REF615R ANSI: 4.0 and 4.0 FP1; Relion Protection Relays RER615: 1.0, 1.1, and 2.0; Relion Protection Relays REC615: 1.0, 1.1, and 2.0; Relion Protection Relays REX615: PCL1 (6.0); Relion Protection Relays 615 series IEC: 3.1, 4.0, 4.0 FP1, 5.0, and 5.0 FP1; Relion Protection Relays 615 series CN: 3.1, 4.1, and 5.0 FP1; Relion Protection Relays 615 series ANSI: 4.0, 4.0 FP1, 4.0 FP2, and 5.0 FP1; Relion Protection Relays RER620 ANSI: 1.1, 1.2, and 1.3; Relion Protection Relays 620 series ANSI: 2.0 and 2.0 FP1; Relion Protection Relays 620 series IEC/CN: 2.0 and 2.0 FP1; Substation Merging Unit SMU615: 1.0.\u003c/p\u003e"
                }
              ],
              "value": "Incorrect Authorization vulnerability in ABB Relion Protection Relays REX610, ABB Relion Protection Relays RE_611 IEC/CN, ABB Relion Protection Relays RBX615, ABB Relion Protection Relays REF615 ANSI, ABB Relion Protection Relays REF615R ANSI, ABB Relion Protection Relays RER615, ABB Relion Protection Relays REC615, ABB Relion Protection Relays REX615, ABB Relion Protection Relays 615 series IEC, ABB Relion Protection Relays 615 series CN, ABB Relion Protection Relays 615 series ANSI, ABB Relion Protection Relays RER620 ANSI, ABB Relion Protection Relays 620 series ANSI, ABB Relion Protection Relays 620 series IEC/CN, and ABB Substation Merging Unit SMU615.\n\nThis issue affects Relion Protection Relays REX610: 1.0, 1.1, and 1.2; Relion Protection Relays RE_611 IEC/CN: 1.0 and 2.0; Relion Protection Relays RBX615: 1.0 and 2.0; Relion Protection Relays REF615 ANSI: 4.1; Relion Protection Relays REF615R ANSI: 4.0 and 4.0 FP1; Relion Protection Relays RER615: 1.0, 1.1, and 2.0; Relion Protection Relays REC615: 1.0, 1.1, and 2.0; Relion Protection Relays REX615: PCL1 (6.0); Relion Protection Relays 615 series IEC: 3.1, 4.0, 4.0 FP1, 5.0, and 5.0 FP1; Relion Protection Relays 615 series CN: 3.1, 4.1, and 5.0 FP1; Relion Protection Relays 615 series ANSI: 4.0, 4.0 FP1, 4.0 FP2, and 5.0 FP1; Relion Protection Relays RER620 ANSI: 1.1, 1.2, and 1.3; Relion Protection Relays 620 series ANSI: 2.0 and 2.0 FP1; Relion Protection Relays 620 series IEC/CN: 2.0 and 2.0 FP1; Substation Merging Unit SMU615: 1.0."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NO",
                "Recovery": "USER",
                "Safety": "PRESENT",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "AMBER",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/S:P/AU:N/R:U/V:D/RE:M/U:Amber",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "MODERATE"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-27T14:15:22.704Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA002995\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Undocumented factory accounts",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2026-4642",
        "datePublished": "2026-11-27T14:15:22.704Z",
        "dateReserved": "2026-03-23T11:23:43.036Z",
        "dateUpdated": "2026-11-27T14:15:22.704Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-4641 (GCVE-0-2026-4641)

    Vulnerability from cvelistv5 – Published: 2026-11-27 14:11 – Updated: 2026-11-27 14:11
    VLAI
    Title
    Weak OTP implementation
    Summary
    Incorrect Authorization vulnerability in ABB Relion Protection Relays REX610, ABB Relion Protection Relays RE_611 IEC/CN, ABB Relion Protection Relays RBX615, ABB Relion Protection Relays REF615 ANSI, ABB Relion Protection Relays REF615R ANSI, ABB Relion Protection Relays RER615, ABB Relion Protection Relays REC615, ABB Relion Protection Relays REX615, ABB Relion Protection Relays 615 series IEC, ABB Relion Protection Relays 615 series CN, ABB Relion Protection Relays 615 series ANSI, ABB Relion Protection Relays RER620 ANSI, ABB Relion Protection Relays 620 series ANSI, ABB Relion Protection Relays 620 series IEC/CN, ABB Relion Protection Relays REX640, and ABB Substation Merging Unit SMU615. This issue affects Relion Protection Relays REX610: 1.0, 1.1, and 1.2; Relion Protection Relays RE_611 IEC/CN: 1.0 and 2.0; Relion Protection Relays RBX615: 1.0 and 2.0; Relion Protection Relays REF615 ANSI: 4.1; Relion Protection Relays REF615R ANSI: 4.0 and 4.0 FP1; Relion Protection Relays RER615: 1.0, 1.1, and 2.0; Relion Protection Relays REC615: 1.0, 1.1, 2.0, and 3.0; Relion Protection Relays REX615: PCL1 (6.0), PCL2 (SW 6.1), and PCL3 (SW 6.2); Relion Protection Relays 615 series IEC: 3.1, 4.0, 4.0 FP1, 5.0, and 5.0 FP1; Relion Protection Relays 615 series CN: 3.1, 4.1, and 5.0 FP1; Relion Protection Relays 615 series ANSI: 4.0, 4.0 FP1, 4.0 FP2, and 5.0 FP1; Relion Protection Relays RER620 ANSI: 1.1, 1.2, and 1.3; Relion Protection Relays 620 series ANSI: 2.0 and 2.0 FP1; Relion Protection Relays 620 series IEC/CN: 2.0 and 2.0 FP1; Relion Protection Relays REX640: PCL1 (1.0), PCL1 (1.1), PCL1 (1.2), PCL1 (1.3), PCL1 (2.0), PCL2 (1.0), PCL2 (1.1), PCL2 (1.2), PCL2 (1.3), PCL2 (2.0), PCL3 (1.0), PCL3 (1.1), PCL3 (1.2), PCL3 (1.3), PCL3 (2.0), PCL4 (1.0), PCL4 (1.1), PCL4 (1.2), PCL4 (1.3), PCL4 (2.0), PCL5 (1.0), PCL5 (1.1), PCL5 (1.2), PCL5 (1.3), PCL5 (2.0), PCL6 (SW 6.1), and PCL7 (SW 6.2); Substation Merging Unit SMU615: 1.0.
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    ABB CNA under the icscert root
    CNA scorecard C 68/100 over 20 records in the last 180 days details
    Impacted products
    Vendor Product Version
    ABB Relion Protection Relays REX610 Affected: 1.0 (custom)
    Affected: 1.1 (custom)
    Affected: 1.2 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays RE_611 IEC/CN Affected: 1.0 (custom)
    Affected: 2.0 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays RBX615 Affected: 1.0 (custom)
    Affected: 2.0 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays REF615 ANSI Affected: 4.1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays REF615R ANSI Affected: 4.0 (custom)
    Affected: 4.0 FP1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays RER615 Affected: 1.0 (custom)
    Affected: 1.1 (custom)
    Affected: 2.0 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays REC615 Affected: 1.0 (custom)
    Affected: 1.1 (custom)
    Affected: 2.0 (custom)
    Affected: 3.0 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays REX615 Affected: PCL1 (6.0) (custom)
    Affected: PCL2 (SW 6.1) (custom)
    Affected: PCL3 (SW 6.2) (custom)
    Create a notification for this product.
    ABB Relion Protection Relays 615 series IEC Affected: 3.1 (custom)
    Affected: 4.0 (custom)
    Affected: 4.0 FP1 (custom)
    Affected: 5.0 (custom)
    Affected: 5.0 FP1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays 615 series CN Affected: 3.1 (custom)
    Affected: 4.1 (custom)
    Affected: 5.0 FP1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays 615 series ANSI Affected: 4.0 (custom)
    Affected: 4.0 FP1 (custom)
    Affected: 4.0 FP2 (custom)
    Affected: 5.0 FP1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays RER620 ANSI Affected: 1.1 (custom)
    Affected: 1.2 (custom)
    Affected: 1.3 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays 620 series ANSI Affected: 2.0 (custom)
    Affected: 2.0 FP1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays 620 series IEC/CN Affected: 2.0 (custom)
    Affected: 2.0 FP1 (custom)
    Create a notification for this product.
    ABB Relion Protection Relays REX640 Affected: PCL1 (1.0) (custom)
    Affected: PCL1 (1.1) (custom)
    Affected: PCL1 (1.2) (custom)
    Affected: PCL1 (1.3) (custom)
    Affected: PCL1 (2.0) (custom)
    Affected: PCL2 (1.0) (custom)
    Affected: PCL2 (1.1) (custom)
    Affected: PCL2 (1.2) (custom)
    Affected: PCL2 (1.3) (custom)
    Affected: PCL2 (2.0) (custom)
    Affected: PCL3 (1.0) (custom)
    Affected: PCL3 (1.1) (custom)
    Affected: PCL3 (1.2) (custom)
    Affected: PCL3 (1.3) (custom)
    Affected: PCL3 (2.0) (custom)
    Affected: PCL4 (1.0) (custom)
    Affected: PCL4 (1.1) (custom)
    Affected: PCL4 (1.2) (custom)
    Affected: PCL4 (1.3) (custom)
    Affected: PCL4 (2.0) (custom)
    Affected: PCL5 (1.0) (custom)
    Affected: PCL5 (1.1) (custom)
    Affected: PCL5 (1.2) (custom)
    Affected: PCL5 (1.3) (custom)
    Affected: PCL5 (2.0) (custom)
    Affected: PCL6 (SW 6.1) (custom)
    Affected: PCL7 (SW 6.2) (custom)
    Create a notification for this product.
    ABB Substation Merging Unit SMU615 Affected: 1.0 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays REX610",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays RE_611 IEC/CN",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays RBX615",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays REF615 ANSI",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays REF615R ANSI",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "4.0 FP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays RER615",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays REC615",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "3.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays REX615",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "PCL1 (6.0)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL2 (SW 6.1)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL3 (SW 6.2)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays 615 series IEC",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "4.0 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "5.0 FP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays 615 series CN",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "4.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "5.0 FP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays 615 series ANSI",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "4.0 FP1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "4.0 FP2",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "5.0 FP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays RER620 ANSI",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.2",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "1.3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays 620 series ANSI",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0 FP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays 620 series IEC/CN",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "2.0 FP1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Relion Protection Relays REX640",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "PCL1 (1.0)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL1 (1.1)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL1 (1.2)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL1 (1.3)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL1 (2.0)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL2 (1.0)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL2 (1.1)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL2 (1.2)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL2 (1.3)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL2 (2.0)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL3 (1.0)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL3 (1.1)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL3 (1.2)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL3 (1.3)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL3 (2.0)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL4 (1.0)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL4 (1.1)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL4 (1.2)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL4 (1.3)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL4 (2.0)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL5 (1.0)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL5 (1.1)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL5 (1.2)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL5 (1.3)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL5 (2.0)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL6 (SW 6.1)",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "PCL7 (SW 6.2)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Substation Merging Unit SMU615",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Incorrect Authorization vulnerability in ABB Relion Protection Relays REX610, ABB Relion Protection Relays RE_611 IEC/CN, ABB Relion Protection Relays RBX615, ABB Relion Protection Relays REF615 ANSI, ABB Relion Protection Relays REF615R ANSI, ABB Relion Protection Relays RER615, ABB Relion Protection Relays REC615, ABB Relion Protection Relays REX615, ABB Relion Protection Relays 615 series IEC, ABB Relion Protection Relays 615 series CN, ABB Relion Protection Relays 615 series ANSI, ABB Relion Protection Relays RER620 ANSI, ABB Relion Protection Relays 620 series ANSI, ABB Relion Protection Relays 620 series IEC/CN, ABB Relion Protection Relays REX640, and ABB Substation Merging Unit SMU615.\u003cp\u003eThis issue affects Relion Protection Relays REX610: 1.0, 1.1, and 1.2; Relion Protection Relays RE_611 IEC/CN: 1.0 and 2.0; Relion Protection Relays RBX615: 1.0 and 2.0; Relion Protection Relays REF615 ANSI: 4.1; Relion Protection Relays REF615R ANSI: 4.0 and 4.0 FP1; Relion Protection Relays RER615: 1.0, 1.1, and 2.0; Relion Protection Relays REC615: 1.0, 1.1, 2.0, and 3.0; Relion Protection Relays REX615: PCL1 (6.0), PCL2 (SW 6.1), and PCL3 (SW 6.2); Relion Protection Relays 615 series IEC: 3.1, 4.0, 4.0 FP1, 5.0, and 5.0 FP1; Relion Protection Relays 615 series CN: 3.1, 4.1, and 5.0 FP1; Relion Protection Relays 615 series ANSI: 4.0, 4.0 FP1, 4.0 FP2, and 5.0 FP1; Relion Protection Relays RER620 ANSI: 1.1, 1.2, and 1.3; Relion Protection Relays 620 series ANSI: 2.0 and 2.0 FP1; Relion Protection Relays 620 series IEC/CN: 2.0 and 2.0 FP1; Relion Protection Relays REX640: PCL1 (1.0), PCL1 (1.1), PCL1 (1.2), PCL1 (1.3), PCL1 (2.0), PCL2 (1.0), PCL2 (1.1), PCL2 (1.2), PCL2 (1.3), PCL2 (2.0), PCL3 (1.0), PCL3 (1.1), PCL3 (1.2), PCL3 (1.3), PCL3 (2.0), PCL4 (1.0), PCL4 (1.1), PCL4 (1.2), PCL4 (1.3), PCL4 (2.0), PCL5 (1.0), PCL5 (1.1), PCL5 (1.2), PCL5 (1.3), PCL5 (2.0), PCL6 (SW 6.1), and PCL7 (SW 6.2); Substation Merging Unit SMU615: 1.0.\u003c/p\u003e"
                }
              ],
              "value": "Incorrect Authorization vulnerability in ABB Relion Protection Relays REX610, ABB Relion Protection Relays RE_611 IEC/CN, ABB Relion Protection Relays RBX615, ABB Relion Protection Relays REF615 ANSI, ABB Relion Protection Relays REF615R ANSI, ABB Relion Protection Relays RER615, ABB Relion Protection Relays REC615, ABB Relion Protection Relays REX615, ABB Relion Protection Relays 615 series IEC, ABB Relion Protection Relays 615 series CN, ABB Relion Protection Relays 615 series ANSI, ABB Relion Protection Relays RER620 ANSI, ABB Relion Protection Relays 620 series ANSI, ABB Relion Protection Relays 620 series IEC/CN, ABB Relion Protection Relays REX640, and ABB Substation Merging Unit SMU615.\n\nThis issue affects Relion Protection Relays REX610: 1.0, 1.1, and 1.2; Relion Protection Relays RE_611 IEC/CN: 1.0 and 2.0; Relion Protection Relays RBX615: 1.0 and 2.0; Relion Protection Relays REF615 ANSI: 4.1; Relion Protection Relays REF615R ANSI: 4.0 and 4.0 FP1; Relion Protection Relays RER615: 1.0, 1.1, and 2.0; Relion Protection Relays REC615: 1.0, 1.1, 2.0, and 3.0; Relion Protection Relays REX615: PCL1 (6.0), PCL2 (SW 6.1), and PCL3 (SW 6.2); Relion Protection Relays 615 series IEC: 3.1, 4.0, 4.0 FP1, 5.0, and 5.0 FP1; Relion Protection Relays 615 series CN: 3.1, 4.1, and 5.0 FP1; Relion Protection Relays 615 series ANSI: 4.0, 4.0 FP1, 4.0 FP2, and 5.0 FP1; Relion Protection Relays RER620 ANSI: 1.1, 1.2, and 1.3; Relion Protection Relays 620 series ANSI: 2.0 and 2.0 FP1; Relion Protection Relays 620 series IEC/CN: 2.0 and 2.0 FP1; Relion Protection Relays REX640: PCL1 (1.0), PCL1 (1.1), PCL1 (1.2), PCL1 (1.3), PCL1 (2.0), PCL2 (1.0), PCL2 (1.1), PCL2 (1.2), PCL2 (1.3), PCL2 (2.0), PCL3 (1.0), PCL3 (1.1), PCL3 (1.2), PCL3 (1.3), PCL3 (2.0), PCL4 (1.0), PCL4 (1.1), PCL4 (1.2), PCL4 (1.3), PCL4 (2.0), PCL5 (1.0), PCL5 (1.1), PCL5 (1.2), PCL5 (1.3), PCL5 (2.0), PCL6 (SW 6.1), and PCL7 (SW 6.2); Substation Merging Unit SMU615: 1.0."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NO",
                "Recovery": "USER",
                "Safety": "PRESENT",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "AMBER",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/S:P/AU:N/R:U/V:D/RE:H/U:Amber",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "HIGH"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-27T14:11:27.327Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2NGA002995\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Weak OTP implementation",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2026-4641",
        "datePublished": "2026-11-27T14:11:27.327Z",
        "dateReserved": "2026-03-23T11:23:37.433Z",
        "dateUpdated": "2026-11-27T14:11:27.327Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-135278 (GCVE-0-2026-135278)

    Vulnerability from cvelistv5 – Published: 2026-11-27 13:21 – Updated: 2026-11-27 13:21
    VLAI
    Summary
    A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.24.29), Mendix Runtime V11 (All versions < V11.17.0), Mendix Runtime V11.12 (All versions < V11.12.8), Mendix Runtime V11.6 (All versions < V11.6.13), Mendix Runtime V9 (All versions < V9.24.45). Affected versions of Mendix Runtime do not end existing sessions when a user account is set to inactive. The account state is checked at sign-in, but not on later requests made with a session that already exists. A user who is deactivated while signed in can keep using that session for as long as the client keeps it alive. This could allow an authenticated remote attacker to read and change data within previous permissions for a persistent session.
    CWE
    • CWE-613 - Insufficient Session Expiration
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Mendix Runtime V10",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V10.24.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Mendix Runtime V11",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V11.17.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Mendix Runtime V11.12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V11.12.8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Mendix Runtime V11.6",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V11.6.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Mendix Runtime V9",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V9.24.45",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions \u003c V10.24.29), Mendix Runtime V11 (All versions \u003c V11.17.0), Mendix Runtime V11.12 (All versions \u003c V11.12.8), Mendix Runtime V11.6 (All versions \u003c V11.6.13), Mendix Runtime V9 (All versions \u003c V9.24.45). Affected versions of Mendix Runtime do not end existing sessions when a user account is set to inactive. The account state is checked at sign-in, but not on later requests made with a session that already exists. A user who is deactivated while signed in can keep using that session for as long as the client keeps it alive.\r\n\r\nThis could allow an authenticated remote attacker to read and change data within previous permissions for a persistent session."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-613",
                  "description": "CWE-613: Insufficient Session Expiration",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-27T13:21:54.085Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-579716.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-135278",
        "datePublished": "2026-11-27T13:21:54.085Z",
        "dateReserved": "2026-11-23T16:08:11.807Z",
        "dateUpdated": "2026-11-27T13:21:54.085Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-124981 (GCVE-0-2026-124981)

    Vulnerability from cvelistv5 – Published: 2026-11-27 13:21 – Updated: 2026-11-27 16:05
    VLAI
    Summary
    A vulnerability has been identified in Mendix OIDC Provider (Mendix 10 compatible) (All versions < V6.0.0), Mendix OIDC Provider (Mendix 11 compatible) (All versions < V6.0.0), Mendix OIDC Provider (Mendix 9 compatible) (All versions < V4.3.0). Affected versions of the module do not properly validate the integrity of JWTs submitted to the OIDC Provider Token Introspection endpoint, allowing tokens to be associated with legitimate token records based solely on their jti value. This could allow unauthenticated remote attackers to hijack an account (session) when gaining access to an jti of an active token.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-27 16:05 UTC
    CWE
    • CWE-347 - Improper Verification of Cryptographic Signature
    Assigner
    siemens CNA under the icscert root
    CNA scorecard C 65/100 over 90 records in the last 180 days details
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-124981",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-27T16:05:18.341311Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-27T16:05:31.271Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Mendix OIDC Provider (Mendix 10 compatible)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Mendix OIDC Provider (Mendix 11 compatible)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Mendix OIDC Provider (Mendix 9 compatible)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Mendix OIDC Provider (Mendix 10 compatible) (All versions \u003c V6.0.0), Mendix OIDC Provider (Mendix 11 compatible) (All versions \u003c V6.0.0), Mendix OIDC Provider (Mendix 9 compatible) (All versions \u003c V4.3.0). Affected versions of the module do not properly validate the integrity of JWTs submitted to the OIDC Provider Token Introspection endpoint, allowing tokens to be associated with legitimate token records based solely on their jti value.\r\n\r\nThis could allow unauthenticated remote attackers to hijack an account (session) when gaining access to an jti of an active token."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-347",
                  "description": "CWE-347: Improper Verification of Cryptographic Signature",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-27T13:21:53.018Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-545865.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2026-124981",
        "datePublished": "2026-11-27T13:21:53.018Z",
        "dateReserved": "2026-11-09T15:22:17.447Z",
        "dateUpdated": "2026-11-27T16:05:31.271Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-136760 (GCVE-0-2026-136760)

    Vulnerability from cvelistv5 – Published: 2026-11-26 13:26 – Updated: 2026-11-26 13:26
    VLAI
    Title
    Privilege escalation in Panorama Suite with POSIX LDAP authentication
    Summary
    When authenticating through the Web HMI or Desktop HMI with POSIX LDAP, an attacker can bypass some of Panorama Suite's injection protections. The attacker must know the username and password of a valid account in the LDAP directory. An authenticated attacker may then gain access to areas or business roles they are not authorized to use, or obtain unauthorized permissions in Panorama. Installations that do not use POSIX LDAP authentication are not affected. LDAP Active Directory authentication is not affected. Affected versions: * Panorama Suite 2020 * Panorama Suite 2022-SP1 * Panorama Suite 2023 * Panorama Suite 2025 * Panorama Suite 2025 Updated Dec. 25 (before update PS-2510-02-1317) Remediation: For Panorama Suite 2025 Updated Dec. 25, install update PS-2510-02-1317 or later. For the other affected versions, upgrade to Panorama Suite 2025 Updated Dec. 25 and install update PS-2510-02-1317 or later. Please refer to security bulletin BS-040 on the Panorama CSIRT website: https://my.codra.net/en-gb/csirt .
    CWE
    • CWE-90 - Improper Neutralization of Special Elements used in an LDAP Query ('LDAP Injection')
    Assigner
    CODRA CNA under the icscert root
    CNA scorecard – unranked: 1 record in the last 180 days, 10 needed details
    References
    Impacted products
    Vendor Product Version
    CODRA Panorama Suite Affected: Panorama Suite 2020
    Affected: Panorama Suite 2022-SP1
    Affected: Panorama Suite 2023
    Affected: Panorama Suite 2025
    Affected: Panorama Suite 2025 Updated Dec. 25 , < update PS-2510-02-1317 (custom)
        cpe:2.3:a:codra:panorama_suite:panorama_suite_2020:*:windows:*:*:*:*:*
        cpe:2.3:a:codra:panorama_suite:panorama_suite_2022-sp1:*:windows:*:*:*:*:*
        cpe:2.3:a:codra:panorama_suite:panorama_suite_2023:*:windows:*:*:*:*:*
        cpe:2.3:a:codra:panorama_suite:panorama_suite_2025:*:windows:*:*:*:*:*
        cpe:2.3:a:codra:panorama_suite:*:*:windows:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "Panorama Web HMI Server",
                "Panorama Desktop HMI"
              ],
              "platforms": [
                "Windows"
              ],
              "product": "Panorama Suite",
              "vendor": "CODRA",
              "versions": [
                {
                  "status": "affected",
                  "version": "Panorama Suite 2020"
                },
                {
                  "status": "affected",
                  "version": "Panorama Suite 2022-SP1"
                },
                {
                  "status": "affected",
                  "version": "Panorama Suite 2023"
                },
                {
                  "status": "affected",
                  "version": "Panorama Suite 2025"
                },
                {
                  "lessThan": "update PS-2510-02-1317",
                  "status": "affected",
                  "version": "Panorama Suite 2025 Updated Dec. 25",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:codra:panorama_suite:panorama_suite_2020:*:windows:*:*:*:*:*",
                      "vulnerable": true
                    },
                    {
                      "criteria": "cpe:2.3:a:codra:panorama_suite:panorama_suite_2022-sp1:*:windows:*:*:*:*:*",
                      "vulnerable": true
                    },
                    {
                      "criteria": "cpe:2.3:a:codra:panorama_suite:panorama_suite_2023:*:windows:*:*:*:*:*",
                      "vulnerable": true
                    },
                    {
                      "criteria": "cpe:2.3:a:codra:panorama_suite:panorama_suite_2025:*:windows:*:*:*:*:*",
                      "vulnerable": true
                    },
                    {
                      "criteria": "cpe:2.3:a:codra:panorama_suite:*:*:windows:*:*:*:*:*",
                      "versionEndExcluding": "update_ps-2510-02-1317",
                      "versionStartIncluding": "panorama_suite_2025_updated_dec._25",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eWhen authenticating through the Web HMI or Desktop HMI with POSIX LDAP, an attacker can bypass some of Panorama Suite\u0027s injection protections. The attacker must know the username and password of a valid account in the LDAP directory. An authenticated attacker may then gain access to areas or business roles they are not authorized to use, or obtain unauthorized permissions in Panorama. Installations that do not use POSIX LDAP authentication are not affected. LDAP Active Directory authentication is not affected.\u003c/p\u003e\u003cp\u003eAffected versions:\u003c/p\u003e\u003cul\u003e\u003cli\u003ePanorama Suite 2020\u003c/li\u003e\u003cli\u003ePanorama Suite 2022-SP1\u003c/li\u003e\u003cli\u003ePanorama Suite 2023\u003c/li\u003e\u003cli\u003ePanorama Suite 2025\u003c/li\u003e\u003cli\u003ePanorama Suite 2025 Updated Dec. 25 (before update PS-2510-02-1317)\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eRemediation: For Panorama Suite 2025 Updated Dec. 25, install update PS-2510-02-1317 or later. For the other affected versions, upgrade to Panorama Suite 2025 Updated Dec. 25 and install update PS-2510-02-1317 or later.\u003c/p\u003e\u003cp\u003ePlease refer to security bulletin BS-040 on the Panorama CSIRT website: \u003ca href=\"https://my.codra.net/en-gb/csirt\"\u003ehttps://my.codra.net/en-gb/csirt\u003c/a\u003e.\u003c/p\u003e"
                }
              ],
              "value": "When authenticating through the Web HMI or Desktop HMI with POSIX LDAP, an attacker can bypass some of Panorama Suite\u0027s injection protections. The attacker must know the username and password of a valid account in the LDAP directory. An authenticated attacker may then gain access to areas or business roles they are not authorized to use, or obtain unauthorized permissions in Panorama. Installations that do not use POSIX LDAP authentication are not affected. LDAP Active Directory authentication is not affected.\n\n\n\nAffected versions:\n\n  *  Panorama Suite 2020\n  *  Panorama Suite 2022-SP1\n  *  Panorama Suite 2023\n  *  Panorama Suite 2025\n  *  Panorama Suite 2025 Updated Dec. 25 (before update PS-2510-02-1317)\n\n\n\n\nRemediation: For Panorama Suite 2025 Updated Dec. 25, install update PS-2510-02-1317 or later. For the other affected versions, upgrade to Panorama Suite 2025 Updated Dec. 25 and install update PS-2510-02-1317 or later.\n\n\n\nPlease refer to security bulletin BS-040 on the Panorama CSIRT website:  https://my.codra.net/en-gb/csirt ."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-136",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-136 LDAP Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-90",
                  "description": "CWE-90 Improper Neutralization of Special Elements used in an LDAP Query (\u0027LDAP Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-26T13:26:17.025Z",
            "orgId": "30aa36b7-a224-4bc9-b7d3-abea20aa4887",
            "shortName": "CODRA"
          },
          "references": [
            {
              "name": "Panorama CSIRT",
              "url": "https://my.codra.net/en-gb/csirt"
            }
          ],
          "source": {
            "advisory": "Pano/BS-040",
            "discovery": "INTERNAL"
          },
          "title": "Privilege escalation in Panorama Suite with POSIX LDAP authentication",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "30aa36b7-a224-4bc9-b7d3-abea20aa4887",
        "assignerShortName": "CODRA",
        "cveId": "CVE-2026-136760",
        "datePublished": "2026-11-26T13:26:17.025Z",
        "dateReserved": "2026-11-25T09:57:33.858Z",
        "dateUpdated": "2026-11-26T13:26:17.025Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123689 (GCVE-0-2026-123689)

    Vulnerability from cvelistv5 – Published: 2026-11-26 03:07 – Updated: 2026-11-26 03:07
    VLAI
    Summary
    A SQL injection vulnerability exists in the Search Agents API of StellarOne due to improper sanitization of user-supplied input. An authenticated attacker with Viewer privileges can send crafted requests to manipulate backend SQL queries. This issue affects StellarOne: before 5.0.3232.
    CWE
    • CWE-89 - Improper neutralization of special elements used in an SQL command ('SQL injection')
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    TXOne Networks StellarOne Affected: 0 , < 5.0.3232 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StellarOne",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "5.0.3232",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A SQL injection vulnerability exists in the Search Agents API of StellarOne due to improper sanitization of user-supplied input. An authenticated attacker with Viewer privileges can send crafted requests to manipulate backend SQL queries. This issue affects StellarOne: before 5.0.3232."
                }
              ],
              "value": "A SQL injection vulnerability exists in the Search Agents API of StellarOne due to improper sanitization of user-supplied input. An authenticated attacker with Viewer privileges can send crafted requests to manipulate backend SQL queries. This issue affects StellarOne: before 5.0.3232."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper neutralization of special elements used in an SQL command (\u0027SQL injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-26T03:07:22.595Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-123689"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-123689",
        "datePublished": "2026-11-26T03:07:22.595Z",
        "dateReserved": "2026-11-06T09:46:46.639Z",
        "dateUpdated": "2026-11-26T03:07:22.595Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123688 (GCVE-0-2026-123688)

    Vulnerability from cvelistv5 – Published: 2026-11-26 03:06 – Updated: 2026-11-26 03:06
    VLAI
    Summary
    An improper authorization vulnerability exists in the patch management functionality of StellarOne. An attacker with Viewer web access can perform administrative patch management operations. This issue affects StellarOne: before 5.0.3232.
    CWE
    • CWE-863 - Incorrect authorization
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    TXOne Networks StellarOne Affected: 0 , < 5.0.3232 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StellarOne",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "5.0.3232",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An improper authorization vulnerability exists in the patch management functionality of StellarOne. An attacker with Viewer web access can perform administrative patch management operations. This issue affects StellarOne: before 5.0.3232."
                }
              ],
              "value": "An improper authorization vulnerability exists in the patch management functionality of StellarOne. An attacker with Viewer web access can perform administrative patch management operations. This issue affects StellarOne: before 5.0.3232."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-26T03:06:19.474Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-123688"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-123688",
        "datePublished": "2026-11-26T03:06:19.474Z",
        "dateReserved": "2026-11-06T09:45:07.143Z",
        "dateUpdated": "2026-11-26T03:06:19.474Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123687 (GCVE-0-2026-123687)

    Vulnerability from cvelistv5 – Published: 2026-11-26 03:05 – Updated: 2026-11-26 03:05
    VLAI
    Summary
    An arbitrary file write vulnerability exists in the patch upload functionality of StellarOne due to improper validation of file paths. An attacker with admin web access can upload a crafted patch package to write arbitrary files on endpoints with the privileges of the endpoint service. This issue affects StellarOne: before 5.0.3232.
    CWE
    • CWE-73 - External control of file name or path
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    TXOne Networks StellarOne Affected: 0 , < 5.0.3232 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StellarOne",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "5.0.3232",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An arbitrary file write vulnerability exists in the patch upload functionality of StellarOne due to improper validation of file paths. An attacker with admin web access can upload a crafted patch package to write arbitrary files on endpoints with the privileges of the endpoint service. This issue affects StellarOne: before 5.0.3232."
                }
              ],
              "value": "An arbitrary file write vulnerability exists in the patch upload functionality of StellarOne due to improper validation of file paths. An attacker with admin web access can upload a crafted patch package to write arbitrary files on endpoints with the privileges of the endpoint service. This issue affects StellarOne: before 5.0.3232."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-73",
                  "description": "CWE-73 External control of file name or path",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-26T03:05:40.276Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-123687"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-123687",
        "datePublished": "2026-11-26T03:05:40.276Z",
        "dateReserved": "2026-11-06T09:45:07.143Z",
        "dateUpdated": "2026-11-26T03:05:40.276Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123686 (GCVE-0-2026-123686)

    Vulnerability from cvelistv5 – Published: 2026-11-26 03:04 – Updated: 2026-11-26 03:04
    VLAI
    Summary
    An OS command injection vulnerability exists in the vShell command-line interface of StellarOne due to improper validation of user-supplied input. An authenticated attacker with access to vShell can inject crafted commands to bypass the restricted shell environment and execute arbitrary operating system commands. This issue affects StellarOne: before 5.0.3232.
    CWE
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    TXOne Networks StellarOne Affected: 0 , < 5.0.3232 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StellarOne",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "5.0.3232",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An OS command injection vulnerability exists in the vShell command-line interface of StellarOne due to improper validation of user-supplied input. An authenticated attacker with access to vShell can inject crafted commands to bypass the restricted shell environment and execute arbitrary operating system commands. This issue affects StellarOne: before 5.0.3232."
                }
              ],
              "value": "An OS command injection vulnerability exists in the vShell command-line interface of StellarOne due to improper validation of user-supplied input. An authenticated attacker with access to vShell can inject crafted commands to bypass the restricted shell environment and execute arbitrary operating system commands. This issue affects StellarOne: before 5.0.3232."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-26T03:04:26.866Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-123686"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-123686",
        "datePublished": "2026-11-26T03:04:26.866Z",
        "dateReserved": "2026-11-06T09:45:07.143Z",
        "dateUpdated": "2026-11-26T03:04:26.866Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123685 (GCVE-0-2026-123685)

    Vulnerability from cvelistv5 – Published: 2026-11-26 03:03 – Updated: 2026-11-26 03:03
    VLAI
    Summary
    A remote code execution vulnerability exists in the patch apply functionality of StellarProtect Linux and Stellar Agent (Linux) due to insufficient validation of uploaded patch packages before extraction. An attacker with low-privileged web access can upload a crafted patch package to execute arbitrary programs with root privileges on the server. This issue affects StellarProtect Linux: 1.0 and earlier; Stellar Agent (Linux): before 1.2.54. *Note: Stellar Agent (Linux) is the new name for StellarProtect Linux.
    CWE
    • CWE-345 - Insufficient verification of data authenticity
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Stellar Agent (Linux)",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "1.2.54",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "StellarProtect Linux",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThanOrEqual": "1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A remote code execution vulnerability exists in the patch apply functionality of StellarProtect Linux and Stellar Agent (Linux) due to insufficient validation of uploaded patch packages before extraction. An attacker with low-privileged web access can upload a crafted patch package to execute arbitrary programs with root privileges on the server. This issue affects StellarProtect Linux: 1.0 and earlier; Stellar Agent (Linux): before 1.2.54. *Note: Stellar Agent (Linux) is the new name for StellarProtect Linux."
                }
              ],
              "value": "A remote code execution vulnerability exists in the patch apply functionality of StellarProtect Linux and Stellar Agent (Linux) due to insufficient validation of uploaded patch packages before extraction. An attacker with low-privileged web access can upload a crafted patch package to execute arbitrary programs with root privileges on the server. This issue affects StellarProtect Linux: 1.0 and earlier; Stellar Agent (Linux): before 1.2.54. *Note: Stellar Agent (Linux) is the new name for StellarProtect Linux."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "CWE-345 Insufficient verification of data authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-26T03:03:06.200Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-123685"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-123685",
        "datePublished": "2026-11-26T03:03:06.200Z",
        "dateReserved": "2026-11-06T09:45:07.143Z",
        "dateUpdated": "2026-11-26T03:03:06.200Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123684 (GCVE-0-2026-123684)

    Vulnerability from cvelistv5 – Published: 2026-11-26 03:02 – Updated: 2026-11-26 03:02
    VLAI
    Summary
    An improper version validation vulnerability exists in the product update mechanism of StellarProtect Linux and Stellar Agent (Linux). An attacker with product admin privileges can downgrade the product to an older, potentially vulnerable version, potentially allowing previously patched vulnerabilities to be reintroduced and security protections to be weakened. This issue affects StellarProtect Linux: 1.0 and earlier; Stellar Agent (Linux): before 1.2.54. *Note: Stellar Agent (Linux) is the new name for StellarProtect Linux.
    CWE
    • CWE-841 - Improper enforcement of behavioral workflow
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Stellar Agent (Linux)",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "1.2.54",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "StellarProtect Linux",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThanOrEqual": "1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An improper version validation vulnerability exists in the product update mechanism of StellarProtect Linux and Stellar Agent (Linux). An attacker with product admin privileges can downgrade the product to an older, potentially vulnerable version, potentially allowing previously patched vulnerabilities to be reintroduced and security protections to be weakened. This issue affects StellarProtect Linux: 1.0 and earlier; Stellar Agent (Linux): before 1.2.54. *Note: Stellar Agent (Linux) is the new name for StellarProtect Linux."
                }
              ],
              "value": "An improper version validation vulnerability exists in the product update mechanism of StellarProtect Linux and Stellar Agent (Linux). An attacker with product admin privileges can downgrade the product to an older, potentially vulnerable version, potentially allowing previously patched vulnerabilities to be reintroduced and security protections to be weakened. This issue affects StellarProtect Linux: 1.0 and earlier; Stellar Agent (Linux): before 1.2.54. *Note: Stellar Agent (Linux) is the new name for StellarProtect Linux."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 6.7,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 4.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-841",
                  "description": "CWE-841 Improper enforcement of behavioral workflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-26T03:02:12.558Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-123684"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-123684",
        "datePublished": "2026-11-26T03:02:12.558Z",
        "dateReserved": "2026-11-06T09:45:07.143Z",
        "dateUpdated": "2026-11-26T03:02:12.558Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123683 (GCVE-0-2026-123683)

    Vulnerability from cvelistv5 – Published: 2026-11-26 03:01 – Updated: 2026-11-26 03:01
    VLAI
    Summary
    A SQL injection vulnerability exists in an Accounts Manager service of StellarOne running inside a container due to improper handling of user-supplied input in SQL queries. An attacker with command execution access to the host system or another container with network connectivity to the affected service can send crafted requests to manipulate backend database queries. This issue affects StellarOne: before 5.0.3232.
    CWE
    • CWE-89 - Improper neutralization of special elements used in an SQL command ('SQL injection')
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    TXOne Networks StellarOne Affected: 0 , < 5.0.3232 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StellarOne",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "5.0.3232",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A SQL injection vulnerability exists in an Accounts Manager service of StellarOne running inside a container due to improper handling of user-supplied input in SQL queries. An attacker with command execution access to the host system or another container with network connectivity to the affected service can send crafted requests to manipulate backend database queries. This issue affects StellarOne: before 5.0.3232."
                }
              ],
              "value": "A SQL injection vulnerability exists in an Accounts Manager service of StellarOne running inside a container due to improper handling of user-supplied input in SQL queries. An attacker with command execution access to the host system or another container with network connectivity to the affected service can send crafted requests to manipulate backend database queries. This issue affects StellarOne: before 5.0.3232."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper neutralization of special elements used in an SQL command (\u0027SQL injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-26T03:01:14.355Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-123683"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-123683",
        "datePublished": "2026-11-26T03:01:14.355Z",
        "dateReserved": "2026-11-06T09:45:07.143Z",
        "dateUpdated": "2026-11-26T03:01:14.355Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123682 (GCVE-0-2026-123682)

    Vulnerability from cvelistv5 – Published: 2026-11-26 03:00 – Updated: 2026-11-26 03:00
    VLAI
    Summary
    An authenticated remote code execution vulnerability exists in the update functionality of StellarOne due to insufficient validation of files contained within uploaded update packages. An attacker with web administrator privileges can upload a crafted update package to execute arbitrary programs with root privileges on the server. This issue affects StellarOne: before 5.0.3232.
    CWE
    • CWE-347 - Improper verification of cryptographic signature
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    TXOne Networks StellarOne Affected: 0 , < 5.0.3232 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StellarOne",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "5.0.3232",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An authenticated remote code execution vulnerability exists in the update functionality of StellarOne due to insufficient validation of files contained within uploaded update packages. An attacker with web administrator privileges can upload a crafted update package to execute arbitrary programs with root privileges on the server. This issue affects StellarOne: before 5.0.3232."
                }
              ],
              "value": "An authenticated remote code execution vulnerability exists in the update functionality of StellarOne due to insufficient validation of files contained within uploaded update packages. An attacker with web administrator privileges can upload a crafted update package to execute arbitrary programs with root privileges on the server. This issue affects StellarOne: before 5.0.3232."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-347",
                  "description": "CWE-347 Improper verification of cryptographic signature",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-26T03:00:12.739Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-123682"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-123682",
        "datePublished": "2026-11-26T03:00:12.739Z",
        "dateReserved": "2026-11-06T09:45:07.143Z",
        "dateUpdated": "2026-11-26T03:00:12.739Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123681 (GCVE-0-2026-123681)

    Vulnerability from cvelistv5 – Published: 2026-11-26 02:58 – Updated: 2026-11-26 02:58
    VLAI
    Summary
    An HTML injection vulnerability exists in the alert notification functionality of StellarOne due to improper sanitization of agent-supplied data. An attacker controlling an agent identity can submit crafted HTML content, potentially allowing the attacker to manipulate displayed content or deceive recipients. This issue affects StellarOne: before 5.0.3232.
    CWE
    • CWE-116 - Improper encoding or escaping of output
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    TXOne Networks StellarOne Affected: 0 , < 5.0.3232 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StellarOne",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "5.0.3232",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An HTML injection vulnerability exists in the alert notification functionality of StellarOne due to improper sanitization of agent-supplied data. An attacker controlling an agent identity can submit crafted HTML content, potentially allowing the attacker to manipulate displayed content or deceive recipients. This issue affects StellarOne: before 5.0.3232."
                }
              ],
              "value": "An HTML injection vulnerability exists in the alert notification functionality of StellarOne due to improper sanitization of agent-supplied data. An attacker controlling an agent identity can submit crafted HTML content, potentially allowing the attacker to manipulate displayed content or deceive recipients. This issue affects StellarOne: before 5.0.3232."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 2.3,
                "baseSeverity": "LOW",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 3.1,
                "baseSeverity": "LOW",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-116",
                  "description": "CWE-116 Improper encoding or escaping of output",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-26T02:58:53.579Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-123681"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-123681",
        "datePublished": "2026-11-26T02:58:53.579Z",
        "dateReserved": "2026-11-06T09:45:07.143Z",
        "dateUpdated": "2026-11-26T02:58:53.579Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123680 (GCVE-0-2026-123680)

    Vulnerability from cvelistv5 – Published: 2026-11-26 02:57 – Updated: 2026-11-26 02:57
    VLAI
    Summary
    An authenticated remote code execution vulnerability exists in the firmware update functionality of StellarOne. An attacker with admin privileges can upload a crafted firmware package to execute arbitrary programs with root privileges on the system. This issue affects StellarOne: before 5.0.3232.
    CWE
    • CWE-347 - Improper verification of cryptographic signature
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    TXOne Networks StellarOne Affected: 0 , < 5.0.3232 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StellarOne",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "5.0.3232",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An authenticated remote code execution vulnerability exists in the firmware update functionality of StellarOne. An attacker with admin privileges can upload a crafted firmware package to execute arbitrary programs with root privileges on the system. This issue affects StellarOne: before 5.0.3232."
                }
              ],
              "value": "An authenticated remote code execution vulnerability exists in the firmware update functionality of StellarOne. An attacker with admin privileges can upload a crafted firmware package to execute arbitrary programs with root privileges on the system. This issue affects StellarOne: before 5.0.3232."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-347",
                  "description": "CWE-347 Improper verification of cryptographic signature",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-26T02:57:53.881Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-123680"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-123680",
        "datePublished": "2026-11-26T02:57:53.881Z",
        "dateReserved": "2026-11-06T09:45:07.143Z",
        "dateUpdated": "2026-11-26T02:57:53.881Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123679 (GCVE-0-2026-123679)

    Vulnerability from cvelistv5 – Published: 2026-11-26 02:54 – Updated: 2026-11-26 02:54
    VLAI
    Summary
    An improper access control vulnerability exists in a privileged Unix domain socket of StellarProtect Linux and Stellar Agent (Linux). Due to insufficient authorization checks, a low-privileged local attacker can interact with the daemon and invoke privileged operations without the necessary permissions. This issue affects StellarProtect Linux: 1.0 and earlier; Stellar Agent (Linux): before 1.2.54. *Note: Stellar Agent (Linux) is the new name for StellarProtect Linux.
    CWE
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Stellar Agent (Linux)",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "1.2.54",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "StellarProtect Linux",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThanOrEqual": "1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An improper access control vulnerability exists in a privileged Unix domain socket of StellarProtect Linux and Stellar Agent (Linux). Due to insufficient authorization checks, a low-privileged local attacker can interact with the daemon and invoke privileged operations without the necessary permissions. This issue affects StellarProtect Linux: 1.0 and earlier; Stellar Agent (Linux): before 1.2.54. *Note: Stellar Agent (Linux) is the new name for StellarProtect Linux."
                }
              ],
              "value": "An improper access control vulnerability exists in a privileged Unix domain socket of StellarProtect Linux and Stellar Agent (Linux). Due to insufficient authorization checks, a low-privileged local attacker can interact with the daemon and invoke privileged operations without the necessary permissions. This issue affects StellarProtect Linux: 1.0 and earlier; Stellar Agent (Linux): before 1.2.54. *Note: Stellar Agent (Linux) is the new name for StellarProtect Linux."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "CWE-862 Missing authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-26T02:54:24.263Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-123679"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-123679",
        "datePublished": "2026-11-26T02:54:24.263Z",
        "dateReserved": "2026-11-06T09:45:07.143Z",
        "dateUpdated": "2026-11-26T02:54:24.263Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-127280 (GCVE-0-2026-127280)

    Vulnerability from cvelistv5 – Published: 2026-11-25 15:32 – Updated: 2026-11-25 16:42
    VLAI
    Title
    Heap-based Buffer Overflow in AutomationDirect C-More EA9 Programming Software
    Summary
    C-More EA9 Programming Software V6.80 does not adequately validate data read from a project file before using it in heap memory operations. A crafted file causes a heap buffer overrun during file open, resulting in heap corruption and instability within the application. An attacker can exploit this vulnerability by convincing a user to open a malicious project file delivered through common distribution channels such as email, file sharing, or removable media.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-25 16:38 UTC
    CWE
    • CWE-122 - Heap-based buffer overflow
    Assigner
    icscert CNA under the icscert root
    CNA scorecard B 75/100 over 336 records in the last 180 days details
    Impacted products
    Vendor Product Version
    AutomationDirect C-More EA9 Programming Software Affected: 0 , ≤ V6.80 (custom)
    Unaffected: V6.81
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-127280",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-25T16:38:09.385678Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-25T16:42:26.504Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "C-More EA9 Programming Software",
              "vendor": "AutomationDirect",
              "versions": [
                {
                  "lessThanOrEqual": "V6.80",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "V6.81"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "rgod working with TrendAI Zero Day Initiative"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eC-More EA9 Programming Software V6.80 does not adequately validate data read from a project file before using it in heap memory operations. A crafted file causes a heap buffer overrun during file open, resulting in heap corruption and instability within the application. An attacker can exploit this vulnerability by convincing a user to open a malicious project file delivered through common distribution channels such as email, file sharing, or removable media.\u003c/span\u003e"
                }
              ],
              "value": "C-More EA9 Programming Software V6.80 does not adequately validate data read from a project file before using it in heap memory operations. A crafted file causes a heap buffer overrun during file open, resulting in heap corruption and instability within the application. An attacker can exploit this vulnerability by convincing a user to open a malicious project file delivered through common distribution channels such as email, file sharing, or removable media."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based buffer overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-25T15:32:01.561Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-328-01"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-328-01.json"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eUpdate C-More EA9 Programming Software to V6.81: https://www.automationdirect.com/support/software-downloads\u003c/span\u003e"
                }
              ],
              "value": "Update C-More EA9 Programming Software to V6.81: https://www.automationdirect.com/support/software-downloads"
            }
          ],
          "source": {
            "advisory": "ICSA-26-328-01",
            "discovery": "EXTERNAL"
          },
          "title": "Heap-based Buffer Overflow in AutomationDirect C-More EA9 Programming Software",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003e\nIf you cannot update to the latest software or firmware version right away, apply the following compensating controls to reduce risk until the update can be performed. These measures are temporary and do not replace the update, which remains the primary and recommended remediation. Apply these controls as appropriate based on the vulnerability, assessed risk, operational requirements, and characteristics of your environment. Implement changes under your established management-of-change process. Before implementing isolation, access-control, or network-configuration changes, evaluate potential impacts to safety, availability, and essential operational functions.\u0026nbsp;\u003c/div\u003e\u003cdiv\u003e\u003cul\u003e\u003cli\u003eIsolate affected engineering workstations and OT systems from external and nonessential networks, including the internet and corporate IT networks, where operationally feasible.\u0026nbsp;\u003c/li\u003e\u003cli\u003eDisable or tightly restrict vendor, contractor, and other remote access to the affected OT environment until the vulnerability can be remediated. Where remote access is operationally required, use a hardened jump host, enforce multi-factor authentication, apply least-privilege access, and limit access to authorized, time-bound sessions.\u0026nbsp;\u003c/li\u003e\u003cli\u003eUse trusted, dedicated OT networks for device communication. Where practicable and appropriate to the assessed risk, use dedicated or physically separated infrastructure for higher-criticality systems. Where logical segmentation is used, ensure segmentation controls are appropriately configured, secured, and monitored.\u0026nbsp;\u003c/li\u003e\u003cli\u003eRestrict both physical and logical access to affected systems to authorized personnel only. Apply least-privilege principles to administrative, engineering, maintenance, and service access.\u0026nbsp;\u003c/li\u003e\u003cli\u003eConfigure application allowlisting, where supported, so that only trusted and pre-approved applications are permitted to execute. Block unauthorized software.\u0026nbsp;\u003c/li\u003e\u003cli\u003eUse appropriate antivirus or endpoint detection and response (EDR) tools where supported and compatible with the affected system. Configure host-based and network firewalls to permit only required communications.\u0026nbsp;\u003c/li\u003e\u003cli\u003eDisable unnecessary services, ports, protocols, and communication pathways associated with the affected systems. Where a service or protocol cannot be disabled for operational reasons, restrict access to trusted systems and authorized users wherever possible.\u0026nbsp;\u003c/li\u003e\u003cli\u003eEnable and regularly review available system, security, and network logs to identify suspicious or unauthorized activity. Where appropriate, monitor communications to and from affected systems for unexpected connections or changes in network behavior.\u0026nbsp;\u003c/li\u003e\u003cli\u003eMaintain secure, tested, and preferably offline backups of PLC programs, device configurations, engineering workstation configurations, and other information necessary to restore operations. Periodically verify that backups can be successfully restored.\u0026nbsp;\u003c/li\u003e\u003cli\u003eVerify that critical OT functions can continue operating without unnecessary dependencies on external networks, cloud services, remote-access services, corporate IT services, or other nonessential systems.\u0026nbsp;\u003c/li\u003e\u003cli\u003eIf removable media is required to transfer files into an isolated or restricted environment, use controlled and trusted media and scan it for malicious content before use.\u0026nbsp;\u003c/li\u003e\u003cli\u003eContinuously evaluate the risks associated with operating vulnerable or outdated firmware or software.\u0026nbsp;\u003c/li\u003e\u003c/ul\u003eAdjust compensating controls as the threat environment, operational requirements, or available vulnerability information changes. These compensating controls are intended to reduce exposure while remediation is pending. Organizations should prioritize applying the vendor-provided update as soon as it can be safely tested and deployed within the operational environment.\n\n\u003c/div\u003e"
                }
              ],
              "value": "If you cannot update to the latest software or firmware version right away, apply the following compensating controls to reduce risk until the update can be performed. These measures are temporary and do not replace the update, which remains the primary and recommended remediation. Apply these controls as appropriate based on the vulnerability, assessed risk, operational requirements, and characteristics of your environment. Implement changes under your established management-of-change process. Before implementing isolation, access-control, or network-configuration changes, evaluate potential impacts to safety, availability, and essential operational functions.\u00a0\n\n  *  Isolate affected engineering workstations and OT systems from external and nonessential networks, including the internet and corporate IT networks, where operationally feasible.\u00a0\n  *  Disable or tightly restrict vendor, contractor, and other remote access to the affected OT environment until the vulnerability can be remediated. Where remote access is operationally required, use a hardened jump host, enforce multi-factor authentication, apply least-privilege access, and limit access to authorized, time-bound sessions.\u00a0\n  *  Use trusted, dedicated OT networks for device communication. Where practicable and appropriate to the assessed risk, use dedicated or physically separated infrastructure for higher-criticality systems. Where logical segmentation is used, ensure segmentation controls are appropriately configured, secured, and monitored.\u00a0\n  *  Restrict both physical and logical access to affected systems to authorized personnel only. Apply least-privilege principles to administrative, engineering, maintenance, and service access.\u00a0\n  *  Configure application allowlisting, where supported, so that only trusted and pre-approved applications are permitted to execute. Block unauthorized software.\u00a0\n  *  Use appropriate antivirus or endpoint detection and response (EDR) tools where supported and compatible with the affected system. Configure host-based and network firewalls to permit only required communications.\u00a0\n  *  Disable unnecessary services, ports, protocols, and communication pathways associated with the affected systems. Where a service or protocol cannot be disabled for operational reasons, restrict access to trusted systems and authorized users wherever possible.\u00a0\n  *  Enable and regularly review available system, security, and network logs to identify suspicious or unauthorized activity. Where appropriate, monitor communications to and from affected systems for unexpected connections or changes in network behavior.\u00a0\n  *  Maintain secure, tested, and preferably offline backups of PLC programs, device configurations, engineering workstation configurations, and other information necessary to restore operations. Periodically verify that backups can be successfully restored.\u00a0\n  *  Verify that critical OT functions can continue operating without unnecessary dependencies on external networks, cloud services, remote-access services, corporate IT services, or other nonessential systems.\u00a0\n  *  If removable media is required to transfer files into an isolated or restricted environment, use controlled and trusted media and scan it for malicious content before use.\u00a0\n  *  Continuously evaluate the risks associated with operating vulnerable or outdated firmware or software.\u00a0\n\n\nAdjust compensating controls as the threat environment, operational requirements, or available vulnerability information changes. These compensating controls are intended to reduce exposure while remediation is pending. Organizations should prioritize applying the vendor-provided update as soon as it can be safely tested and deployed within the operational environment."
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-127280",
        "datePublished": "2026-11-25T15:32:01.561Z",
        "dateReserved": "2026-11-12T17:29:40.554Z",
        "dateUpdated": "2026-11-25T16:42:26.504Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123340 (GCVE-0-2026-123340)

    Vulnerability from cvelistv5 – Published: 2026-11-24 19:37 – Updated: 2026-11-24 19:37
    VLAI
    Title
    Copeland XWEB Pro OS command injection
    Summary
    Copeland XWEB Pro contains an OS command injection vulnerability that allows a remote, authenticated attacker to execute arbitrary commands as the root user. Fixed in 1.16.1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · cisa-cg (v2.0.3)
    Decision recorded 2026-11-05 19:04 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    cisa-cg CNA under the CISA root
    CNA scorecard B 76/100 over 148 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Copeland XWEB PRO Affected: 0 , < 1.16.1 (custom)
    Unaffected: 1.16.1
    Create a notification for this product.
    Date Public
    2026-10-29 00:00
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "XWEB PRO",
              "vendor": "Copeland",
              "versions": [
                {
                  "lessThan": "1.16.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "1.16.1"
                }
              ]
            }
          ],
          "datePublic": "2026-10-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Copeland XWEB Pro contains an OS command injection vulnerability that allows a remote, authenticated attacker to execute arbitrary commands as the root user. Fixed in 1.16.1."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH"
              }
            },
            {
              "other": {
                "content": {
                  "id": "CVE-2026-123340",
                  "options": [
                    {
                      "Exploitation": "none"
                    },
                    {
                      "Automatable": "no"
                    },
                    {
                      "Technical Impact": "total"
                    }
                  ],
                  "role": "CISA Coordinator",
                  "timestamp": "2026-11-05T19:04:33.296206Z",
                  "version": "2.0.3"
                },
                "type": "ssvc"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T19:37:37.013Z",
            "orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
            "shortName": "cisa-cg"
          },
          "references": [
            {
              "name": "url",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://webapps.copeland.com/dixell/Content/Pages/SystemSoftwareUpdate/XWEB-PRO/Changelog_XWEB-PRO_v.1.16.1_EN.pdf"
            },
            {
              "name": "url",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://www.cve.org/CVERecord?id=CVE-2026-123215"
            },
            {
              "name": "url",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/IT/white/2026/va-26-328-01.json"
            }
          ],
          "title": "Copeland XWEB Pro OS command injection",
          "x_generator": {
            "engine": "VINCE-NT 1.15.4+build.175"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
        "assignerShortName": "cisa-cg",
        "cveId": "CVE-2026-123340",
        "datePublished": "2026-11-24T19:37:37.013Z",
        "dateReserved": "2026-11-05T18:46:08.987Z",
        "dateUpdated": "2026-11-24T19:37:37.013Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123217 (GCVE-0-2026-123217)

    Vulnerability from cvelistv5 – Published: 2026-11-24 19:37 – Updated: 2026-11-24 19:37
    VLAI
    Title
    Copeland XWEB Pro argument injection
    Summary
    Copeland XWEB Pro allows a remote, authenticated attacker to inject additional arguments into the wireless interface configuration command. Impact is limited to modification of the wireless interface state. Fixed in 1.16.1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · cisa-cg (v2.0.3)
    Decision recorded 2026-11-05 18:03 UTC
    CWE
    • CWE-88 - Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
    Assigner
    cisa-cg CNA under the CISA root
    CNA scorecard B 76/100 over 148 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Copeland XWEB PRO Affected: 0 , < 1.16.1 (custom)
    Unaffected: 1.16.1
    Create a notification for this product.
    Date Public
    2026-10-29 00:00
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "XWEB PRO",
              "vendor": "Copeland",
              "versions": [
                {
                  "lessThan": "1.16.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "1.16.1"
                }
              ]
            }
          ],
          "datePublic": "2026-10-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Copeland XWEB Pro allows a remote, authenticated attacker to inject additional arguments into the wireless interface configuration command. Impact is limited to modification of the wireless interface state. Fixed in 1.16.1."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 2.3,
                "baseSeverity": "LOW",
                "privilegesRequired": "LOW",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW"
              }
            },
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.2,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.1"
              }
            },
            {
              "other": {
                "content": {
                  "id": "CVE-2026-123217",
                  "options": [
                    {
                      "Exploitation": "none"
                    },
                    {
                      "Automatable": "no"
                    },
                    {
                      "Technical Impact": "partial"
                    }
                  ],
                  "role": "CISA Coordinator",
                  "timestamp": "2026-11-05T18:03:46.784310Z",
                  "version": "2.0.3"
                },
                "type": "ssvc"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-88",
                  "description": "CWE-88 Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T19:37:17.624Z",
            "orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
            "shortName": "cisa-cg"
          },
          "references": [
            {
              "name": "url",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://webapps.copeland.com/dixell/Content/Pages/SystemSoftwareUpdate/XWEB-PRO/Changelog_XWEB-PRO_v.1.16.1_EN.pdf"
            },
            {
              "name": "url",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://www.cve.org/CVERecord?id=CVE-2026-123215"
            },
            {
              "name": "url",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/IT/white/2026/va-26-328-01.json"
            }
          ],
          "title": "Copeland XWEB Pro argument injection",
          "x_generator": {
            "engine": "VINCE-NT 1.15.4+build.175"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
        "assignerShortName": "cisa-cg",
        "cveId": "CVE-2026-123217",
        "datePublished": "2026-11-24T19:37:17.624Z",
        "dateReserved": "2026-11-05T18:05:46.837Z",
        "dateUpdated": "2026-11-24T19:37:17.624Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123216 (GCVE-0-2026-123216)

    Vulnerability from cvelistv5 – Published: 2026-11-24 19:36 – Updated: 2026-11-24 19:36
    VLAI
    Title
    Copeland XWEB Pro OS command injection
    Summary
    Copeland XWEB Pro contains an OS command injection vulnerability that allows a remote, authenticated attacker to execute arbitrary commands as the root user. Fixed in 1.16.1.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · cisa-cg (v2.0.3)
    Decision recorded 2026-11-05 18:05 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    cisa-cg CNA under the CISA root
    CNA scorecard B 76/100 over 148 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Copeland XWEB PRO Affected: 0 , < 1.16.1 (custom)
    Unaffected: 1.16.1
    Create a notification for this product.
    Date Public
    2026-10-29 00:00
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "XWEB PRO",
              "vendor": "Copeland",
              "versions": [
                {
                  "lessThan": "1.16.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "1.16.1"
                }
              ]
            }
          ],
          "datePublic": "2026-10-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Copeland XWEB Pro contains an OS command injection vulnerability that allows a remote, authenticated attacker to execute arbitrary commands as the root user. Fixed in 1.16.1."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH"
              }
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "other": {
                "content": {
                  "id": "CVE-2026-123216",
                  "options": [
                    {
                      "Exploitation": "none"
                    },
                    {
                      "Automatable": "no"
                    },
                    {
                      "Technical Impact": "total"
                    }
                  ],
                  "role": "CISA Coordinator",
                  "timestamp": "2026-11-05T18:05:16.790651Z",
                  "version": "2.0.3"
                },
                "type": "ssvc"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T19:36:58.129Z",
            "orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
            "shortName": "cisa-cg"
          },
          "references": [
            {
              "name": "url",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://webapps.copeland.com/dixell/Content/Pages/SystemSoftwareUpdate/XWEB-PRO/Changelog_XWEB-PRO_v.1.16.1_EN.pdf"
            },
            {
              "name": "url",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://www.cve.org/CVERecord?id=CVE-2026-123216"
            },
            {
              "name": "url",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/IT/white/2026/va-26-328-01.json"
            }
          ],
          "title": "Copeland XWEB Pro OS command injection",
          "x_generator": {
            "engine": "VINCE-NT 1.15.4+build.175"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
        "assignerShortName": "cisa-cg",
        "cveId": "CVE-2026-123216",
        "datePublished": "2026-11-24T19:36:58.129Z",
        "dateReserved": "2026-11-05T18:05:46.837Z",
        "dateUpdated": "2026-11-24T19:36:58.129Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-123215 (GCVE-0-2026-123215)

    Vulnerability from cvelistv5 – Published: 2026-11-24 19:36 – Updated: 2026-11-24 19:36
    VLAI
    Title
    Copeland XWEB Pro missing authentication
    Summary
    Copeland XWEB Pro contains a missing authentication vulnerability. Fixed in 1.16.1.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · cisa-cg (v2.0.3)
    Decision recorded 2026-11-05 17:56 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    cisa-cg CNA under the CISA root
    CNA scorecard B 76/100 over 148 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Copeland XWEB PRO Affected: 0 , < 1.16.1 (custom)
    Unaffected: 1.16.1
    Create a notification for this product.
    Date Public
    2026-10-29 00:00
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "XWEB PRO",
              "vendor": "Copeland",
              "versions": [
                {
                  "lessThan": "1.16.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "1.16.1"
                }
              ]
            }
          ],
          "datePublic": "2026-10-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Copeland XWEB Pro contains a missing authentication vulnerability. Fixed in 1.16.1."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH"
              }
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            {
              "other": {
                "content": {
                  "id": "CVE-2026-123215",
                  "options": [
                    {
                      "Exploitation": "none"
                    },
                    {
                      "Automatable": "yes"
                    },
                    {
                      "Technical Impact": "total"
                    }
                  ],
                  "role": "CISA Coordinator",
                  "timestamp": "2026-11-05T17:56:46.011353Z",
                  "version": "2.0.3"
                },
                "type": "ssvc"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T19:36:37.205Z",
            "orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
            "shortName": "cisa-cg"
          },
          "references": [
            {
              "name": "url",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://webapps.copeland.com/dixell/Content/Pages/SystemSoftwareUpdate/XWEB-PRO/Changelog_XWEB-PRO_v.1.16.1_EN.pdf"
            },
            {
              "name": "url",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://www.cve.org/CVERecord?id=CVE-2026-123215"
            },
            {
              "name": "url",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/IT/white/2026/va-26-328-01.json"
            }
          ],
          "title": "Copeland XWEB Pro missing authentication",
          "x_generator": {
            "engine": "VINCE-NT 1.15.4+build.175"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
        "assignerShortName": "cisa-cg",
        "cveId": "CVE-2026-123215",
        "datePublished": "2026-11-24T19:36:37.205Z",
        "dateReserved": "2026-11-05T18:05:46.837Z",
        "dateUpdated": "2026-11-24T19:36:37.205Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-103236 (GCVE-0-2026-103236)

    Vulnerability from cvelistv5 – Published: 2026-11-24 18:16 – Updated: 2026-11-24 18:16
    VLAI
    Title
    User Lock Remains Open After Closure Under Specific Conditions in ACS380-E Firmware
    Summary
    Incorrect Authorization vulnerability in ABB ACS380-E4C02C. This issue affects ACS380-E4C02C: 3.2.0.7 and 3.2.0.9.
    CWE
    • CWE-863 - Incorrect Authorization
    Assigner
    ABB CNA under the icscert root
    CNA scorecard C 68/100 over 20 records in the last 180 days details
    Impacted products
    Vendor Product Version
    ABB ACS380-E4C02C Affected: 3.2.0.7 (custom)
    Affected: 3.2.0.9 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "ACS380-E4C02C",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "3.2.0.7",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "3.2.0.9",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Incorrect Authorization vulnerability in ABB ACS380-E4C02C.\u003cp\u003eThis issue affects ACS380-E4C02C: 3.2.0.7 and 3.2.0.9.\u003c/p\u003e"
                }
              ],
              "value": "Incorrect Authorization vulnerability in ABB ACS380-E4C02C.\n\nThis issue affects ACS380-E4C02C: 3.2.0.7 and 3.2.0.9."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NO",
                "Recovery": "USER",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "LOCAL",
                "baseScore": 5.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "GREEN",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "DIFFUSE",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:A/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/AU:N/R:U/V:D/RE:L/U:Green",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "LOW"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-863",
                  "description": "CWE-863 Incorrect Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T18:16:47.765Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108473A5769\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "User Lock Remains Open After Closure Under Specific Conditions in ACS380-E Firmware",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2026-103236",
        "datePublished": "2026-11-24T18:16:47.765Z",
        "dateReserved": "2026-09-30T09:22:55.690Z",
        "dateUpdated": "2026-11-24T18:16:47.765Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-78354 (GCVE-0-2026-78354)

    Vulnerability from cvelistv5 – Published: 2026-11-24 17:44 – Updated: 2026-11-24 17:44
    VLAI
    Title
    TCP Connection Resource Exhaustion
    Summary
    Missing release of resource after effective lifetime vulnerability in ABB System 800xA Batch Management. This issue affects System 800xA Batch Management: 7.0, 6.2, 6.1.1, and 6.0.3.4.
    CWE
    • CWE-772 - Missing release of resource after effective lifetime
    Assigner
    ABB CNA under the icscert root
    CNA scorecard C 68/100 over 20 records in the last 180 days details
    Impacted products
    Vendor Product Version
    ABB System 800xA Batch Management Affected: 7.0 (custom)
    Affected: 6.2
    Affected: 6.1.1
    Affected: 6.0.3.4
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "System 800xA Batch Management",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "custom"
                },
                {
                  "status": "affected",
                  "version": "6.2"
                },
                {
                  "status": "affected",
                  "version": "6.1.1"
                },
                {
                  "status": "affected",
                  "version": "6.0.3.4"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing release of resource after effective lifetime vulnerability in ABB System 800xA Batch Management.\u003cp\u003eThis issue affects System 800xA Batch Management: 7.0, 6.2, 6.1.1, and 6.0.3.4.\u003c/p\u003e"
                }
              ],
              "value": "Missing release of resource after effective lifetime vulnerability in ABB System 800xA Batch Management.\n\nThis issue affects System 800xA Batch Management: 7.0, 6.2, 6.1.1, and 6.0.3.4."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-772",
                  "description": "CWE-772 Missing release of resource after effective lifetime",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T17:44:54.589Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA025875\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "TCP Connection Resource Exhaustion",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2026-78354",
        "datePublished": "2026-11-24T17:44:54.589Z",
        "dateReserved": "2026-08-24T11:20:28.354Z",
        "dateUpdated": "2026-11-24T17:44:54.589Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-77673 (GCVE-0-2026-77673)

    Vulnerability from cvelistv5 – Published: 2026-11-24 13:51 – Updated: 2026-11-24 17:52
    VLAI
    Summary
    Server-Side Request Forgery in the SSO SAML configuration feature of the TXOne StellarOne web console allows an authenticated administrator to issue server-side requests to arbitrary destinations, including internal services. This issue affects StellarOne: before 5.0.3232.
    CWE
    • CWE-918 - Server-Side Request Forgery (SSRF)
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    TXOne Networks StellarOne Affected: 0 , < 5.0.3232 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "StellarOne",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "5.0.3232",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "FRANCOIS Ulysse, SOHIER Louis and GOBINET Theo of ENGIE IT"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Server-Side Request Forgery in the SSO SAML configuration feature of the TXOne StellarOne web console allows an authenticated administrator to issue server-side requests to arbitrary destinations, including internal services. This issue affects StellarOne: before 5.0.3232."
                }
              ],
              "value": "Server-Side Request Forgery in the SSO SAML configuration feature of the TXOne StellarOne web console allows an authenticated administrator to issue server-side requests to arbitrary destinations, including internal services. This issue affects StellarOne: before 5.0.3232."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 2.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-918",
                  "description": "CWE-918 Server-Side Request Forgery (SSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T17:52:56.520Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-77673"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-77673",
        "datePublished": "2026-11-24T13:51:15.684Z",
        "dateReserved": "2026-08-21T04:43:24.774Z",
        "dateUpdated": "2026-11-24T17:52:56.520Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-77672 (GCVE-0-2026-77672)

    Vulnerability from cvelistv5 – Published: 2026-11-24 13:49 – Updated: 2026-11-24 13:49
    VLAI
    Summary
    Missing server-side authorization in the IPC interface of TXOne StellarProtect and Stellar Agent (Windows) allows a local attacker to issue privileged commands without credentials. This issue affects StellarProtect: 3.3 and earlier; Stellar Agent (Windows): before 5.0.3056. *Note: Stellar Agent (Windows) is the new name for StellarProtect.
    CWE
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Stellar Agent (Windows)",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "5.0.3056",
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "StellarProtect",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThanOrEqual": "3.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "FRANCOIS Ulysse, SOHIER Louis and GOBINET Theo of ENGIE IT"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Missing server-side authorization in the IPC interface of TXOne StellarProtect and Stellar Agent (Windows) allows a local attacker to issue privileged commands without credentials. This issue affects StellarProtect: 3.3 and earlier; Stellar Agent (Windows): before 5.0.3056. *Note: Stellar Agent (Windows) is the new name for StellarProtect."
                }
              ],
              "value": "Missing server-side authorization in the IPC interface of TXOne StellarProtect and Stellar Agent (Windows) allows a local attacker to issue privileged commands without credentials. This issue affects StellarProtect: 3.3 and earlier; Stellar Agent (Windows): before 5.0.3056. *Note: Stellar Agent (Windows) is the new name for StellarProtect."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "CWE-862 Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T13:49:55.203Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-77672"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-77672",
        "datePublished": "2026-11-24T13:49:55.203Z",
        "dateReserved": "2026-08-21T04:43:24.774Z",
        "dateUpdated": "2026-11-24T13:49:55.203Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-77671 (GCVE-0-2026-77671)

    Vulnerability from cvelistv5 – Published: 2026-11-24 13:48 – Updated: 2026-11-24 13:48
    VLAI
    Summary
    Unverified configuration export destination path in TXOne StellarProtect and Stellar Agent (Windows) allows a local attacker to export the product configuration to an arbitrary directory with SYSTEM privileges. This issue affects StellarProtect: 3.3 and earlier; Stellar Agent (Windows): before 5.0.3056. *Note: Stellar Agent (Windows) is the new name for StellarProtect.
    CWE
    • CWE-73 - External control of file name or path
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Stellar Agent (Windows)",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "5.0.3056",
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "StellarProtect",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThanOrEqual": "3.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "FRANCOIS Ulysse, SOHIER Louis and GOBINET Theo of ENGIE IT"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Unverified configuration export destination path in TXOne StellarProtect and Stellar Agent (Windows) allows a local attacker to export the product configuration to an arbitrary directory with SYSTEM privileges. This issue affects StellarProtect: 3.3 and earlier; Stellar Agent (Windows): before 5.0.3056. *Note: Stellar Agent (Windows) is the new name for StellarProtect."
                }
              ],
              "value": "Unverified configuration export destination path in TXOne StellarProtect and Stellar Agent (Windows) allows a local attacker to export the product configuration to an arbitrary directory with SYSTEM privileges. This issue affects StellarProtect: 3.3 and earlier; Stellar Agent (Windows): before 5.0.3056. *Note: Stellar Agent (Windows) is the new name for StellarProtect."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-73",
                  "description": "CWE-73 External control of file name or path",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T13:48:36.143Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-77671"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-77671",
        "datePublished": "2026-11-24T13:48:36.143Z",
        "dateReserved": "2026-08-21T04:43:24.774Z",
        "dateUpdated": "2026-11-24T13:48:36.143Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-77670 (GCVE-0-2026-77670)

    Vulnerability from cvelistv5 – Published: 2026-11-24 13:47 – Updated: 2026-11-24 13:47
    VLAI
    Summary
    Improper access control of a file path in TXOne StellarProtect and Stellar Agent (Windows) allows a local attacker to write or overwrite arbitrary files with SYSTEM privileges. This issue affects StellarProtect: 3.3 and earlier; Stellar Agent (Windows): before 5.0.3056. *Note: Stellar Agent (Windows) is the new name for StellarProtect.
    CWE
    • CWE-73 - External control of file name or path
    Assigner
    TXOne CNA under the icscert root
    CNA scorecard C 74/100 over 16 records in the last 180 days details
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Stellar Agent (Windows)",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThan": "5.0.3056",
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "StellarProtect",
              "vendor": "TXOne Networks",
              "versions": [
                {
                  "lessThanOrEqual": "3.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "FRANCOIS Ulysse, SOHIER Louis and GOBINET Theo of ENGIE IT"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper access control of a file path in TXOne StellarProtect and Stellar Agent (Windows) allows a local attacker to write or overwrite arbitrary files with SYSTEM privileges. This issue affects StellarProtect: 3.3 and earlier; Stellar Agent (Windows): before 5.0.3056. *Note: Stellar Agent (Windows) is the new name for StellarProtect."
                }
              ],
              "value": "Improper access control of a file path in TXOne StellarProtect and Stellar Agent (Windows) allows a local attacker to write or overwrite arbitrary files with SYSTEM privileges. This issue affects StellarProtect: 3.3 and earlier; Stellar Agent (Windows): before 5.0.3056. *Note: Stellar Agent (Windows) is the new name for StellarProtect."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-73",
                  "description": "CWE-73 External control of file name or path",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T13:47:01.973Z",
            "orgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
            "shortName": "TXOne"
          },
          "references": [
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.encyclopedia.txone.com/en-us/support/psirt/CVE-2026-77670"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3ad20294-822c-4ebc-9301-f9a7cf62d46e",
        "assignerShortName": "TXOne",
        "cveId": "CVE-2026-77670",
        "datePublished": "2026-11-24T13:47:01.973Z",
        "dateReserved": "2026-08-21T04:43:24.774Z",
        "dateUpdated": "2026-11-24T13:47:01.973Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-128420 (GCVE-0-2026-128420)

    Vulnerability from cvelistv5 – Published: 2026-11-24 11:31 – Updated: 2026-11-24 11:31
    VLAI
    Title
    Authenticated heap buffer overflow in rms_mqtt
    Summary
    A heap buffer overflow issue exists in the rms_mqtt daemon on Teltonika Networks devices. An authenticated attacker with access to the affected service could trigger a heap-based buffer overflow, resulting in a denial of service. This issue affects RUT: from 7.0 through 7.18.0; RUTX: from 7.0 through 7.18.0; RUTM: from 7.0 through 7.18.0; RUTC: from 7.0 through 7.18.0; ATRM: from 7.16.1 through 7.18.0; TRB: from 7.0 through 7.18.0; OTD: from 7.11.1 through 7.18.0; TAP: from 7.4.3 through 7.18.0; DAP: from 7.12 through 7.18.0; SWM: from 1.6.3 through 1.7.1; TSW: from 1.1 through 1.7.1.
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    Assigner
    tlt_net CNA under the icscert root
    CNA scorecard – unranked: 6 records in the last 180 days, 10 needed details
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "RUT",
              "vendor": "Teltonika Networks",
              "versions": [
                {
                  "lessThanOrEqual": "7.18.0",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "RUTX",
              "vendor": "Teltonika Networks",
              "versions": [
                {
                  "lessThanOrEqual": "7.18.0",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "RUTM",
              "vendor": "Teltonika Networks",
              "versions": [
                {
                  "lessThanOrEqual": "7.18.0",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "RUTC",
              "vendor": "Teltonika Networks",
              "versions": [
                {
                  "lessThanOrEqual": "7.18.0",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ATRM",
              "vendor": "Teltonika Networks",
              "versions": [
                {
                  "lessThanOrEqual": "7.18.0",
                  "status": "affected",
                  "version": "7.16.1",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "TRB",
              "vendor": "Teltonika Networks",
              "versions": [
                {
                  "lessThanOrEqual": "7.18.0",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "OTD",
              "vendor": "Teltonika Networks",
              "versions": [
                {
                  "lessThanOrEqual": "7.18.0",
                  "status": "affected",
                  "version": "7.11.1",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "TAP",
              "vendor": "Teltonika Networks",
              "versions": [
                {
                  "lessThanOrEqual": "7.18.0",
                  "status": "affected",
                  "version": "7.4.3",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "DAP",
              "vendor": "Teltonika Networks",
              "versions": [
                {
                  "lessThanOrEqual": "7.18.0",
                  "status": "affected",
                  "version": "7.12.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "SWM",
              "vendor": "Teltonika Networks",
              "versions": [
                {
                  "lessThanOrEqual": "1.7.1",
                  "status": "affected",
                  "version": "1.6.3",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "TSW",
              "vendor": "Teltonika Networks",
              "versions": [
                {
                  "lessThanOrEqual": "1.7.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A heap buffer overflow issue exists in the rms_mqtt daemon on Teltonika Networks devices. An authenticated attacker with access to the affected service could trigger a heap-based buffer overflow, resulting in a denial of service. This issue affects RUT: from 7.0 through 7.18.0; RUTX: from 7.0 through 7.18.0; RUTM: from 7.0 through 7.18.0; RUTC: from 7.0 through 7.18.0; ATRM: from 7.16.1 through 7.18.0; TRB: from 7.0 through 7.18.0; OTD: from 7.11.1 through 7.18.0; TAP: from 7.4.3 through 7.18.0; DAP: from 7.12 through 7.18.0; SWM: from 1.6.3 through 1.7.1; TSW: from 1.1 through 1.7.1."
                }
              ],
              "value": "A heap buffer overflow issue exists in the rms_mqtt daemon on Teltonika Networks devices. An authenticated attacker with access to the affected service could trigger a heap-based buffer overflow, resulting in a denial of service. This issue affects RUT: from 7.0 through 7.18.0; RUTX: from 7.0 through 7.18.0; RUTM: from 7.0 through 7.18.0; RUTC: from 7.0 through 7.18.0; ATRM: from 7.16.1 through 7.18.0; TRB: from 7.0 through 7.18.0; OTD: from 7.11.1 through 7.18.0; TAP: from 7.4.3 through 7.18.0; DAP: from 7.12 through 7.18.0; SWM: from 1.6.3 through 1.7.1; TSW: from 1.1 through 1.7.1."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "PRESENT",
                "attackVector": "ADJACENT",
                "baseScore": 2,
                "baseSeverity": "LOW",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "HIGH",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:H/UI:N/VC:L/VI:N/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122: Heap-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T11:31:10.195Z",
            "orgId": "001d69cf-3fc9-4203-93fb-9865b54e05b2",
            "shortName": "tlt_net"
          },
          "references": [
            {
              "url": "https://www.teltonika-networks.com/support/security-centre?report=CVE-2026-128420"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Authenticated heap buffer overflow in rms_mqtt",
          "x_generator": {
            "engine": "News Aggregator internal-vulns"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "001d69cf-3fc9-4203-93fb-9865b54e05b2",
        "assignerShortName": "tlt_net",
        "cveId": "CVE-2026-128420",
        "datePublished": "2026-11-24T11:31:10.195Z",
        "dateReserved": "2026-11-13T05:06:34.540Z",
        "dateUpdated": "2026-11-24T11:31:10.195Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-121019 (GCVE-0-2026-121019)

    Vulnerability from cvelistv5 – Published: 2026-11-24 07:51 – Updated: 2026-11-24 14:58
    VLAI
    Title
    Improper Limitation of a Pathname to a Restricted Directory in CODESYS Visualization
    Summary
    An unauthenticated attacker can trick a local user into generating an offline boot application from a malicious CODESYS project, causing the affected products to write files in arbitrary directories on the engineering workstation. The destination path is derived from attacker-controlled project data, whereas the file name and file contents are generated by the affected products and are not attacker-controlled.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-24 14:58 UTC
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    CODESYS Visualization Affected: 3.0.0.0 , < 4.11.0.0 (semver)
        cpe:2.3:a:codesys:codesys_visualization:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-121019",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-24T14:58:08.234133Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-24T14:58:29.652Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Visualization",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:codesys:codesys_visualization:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "4.11.0.0",
                      "versionStartIncluding": "3.0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "f0rw4rd aka Felix Eberstaller from Limes Security / QuellSec"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eAn unauthenticated attacker can trick a local user into generating an offline boot application from a malicious CODESYS project, causing the affected products to write files in arbitrary directories on the engineering workstation. The destination path is derived from attacker-controlled project data, whereas the file name and file contents are generated by the affected products and are not attacker-controlled.\u003c/p\u003e"
                }
              ],
              "value": "An unauthenticated attacker can trick a local user into generating an offline boot application from a malicious CODESYS project, causing the affected products to write files in arbitrary directories on the engineering workstation. The destination path is derived from attacker-controlled project data, whereas the file name and file contents are generated by the affected products and are not attacker-controlled."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 4.6,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "baseSeverity": "LOW",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T07:51:47.811Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-154/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-154",
            "defect": [
              "CERT@VDE#642407"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Improper Limitation of a Pathname to a Restricted Directory in CODESYS Visualization",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-121019",
        "datePublished": "2026-11-24T07:51:47.811Z",
        "dateReserved": "2026-11-03T08:27:12.408Z",
        "dateUpdated": "2026-11-24T14:58:29.652Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-121018 (GCVE-0-2026-121018)

    Vulnerability from cvelistv5 – Published: 2026-11-24 07:51 – Updated: 2026-11-24 16:27
    VLAI
    Title
    Incorrect Resource Transfer Between Spheres in CODESYS Visualization
    Summary
    The affected products insufficiently restrict runtime-supplied visualization commands, allowing local functionality on the engineering workstation to be invoked, if a user is both logged in to a CODESYS Control runtime and operates a visualization. An unauthenticated remote attacker controlling a malicious runtime and tricking a user to trust it, or performing a man-in-the-middle attack on the communication between the CODESYS Control runtime and the engineering workstation, may cause arbitrary code execution on the engineering workstation.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-11-24 16:27 UTC
    CWE
    • CWE-669 - Incorrect Resource Transfer Between Spheres
    Assigner
    CERTVDE CNA under the icscert root
    CNA scorecard B 75/100 over 129 records in the last 180 days details
    References
    Impacted products
    Vendor Product Version
    CODESYS Visualization Affected: 3.0.0.0 , < 4.11.0.0 (semver)
        cpe:2.3:a:codesys:codesys_visualization:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-121018",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-11-24T16:27:28.550404Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-24T16:27:46.839Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Visualization",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.11.0.0",
                  "status": "affected",
                  "version": "3.0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:a:codesys:codesys_visualization:*:*:*:*:*:*:*:*",
                      "versionEndExcluding": "4.11.0.0",
                      "versionStartIncluding": "3.0.0.0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "f0rw4rd aka Felix Eberstaller from Limes Security / QuellSec"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe affected products insufficiently restrict runtime-supplied visualization commands, allowing local functionality on the engineering workstation to be invoked, if a user is both logged in to a CODESYS Control runtime and operates a visualization. An unauthenticated remote attacker controlling a malicious runtime and tricking a user to trust it, or performing a man-in-the-middle attack on the communication between the CODESYS Control runtime and the engineering workstation, may cause arbitrary code execution on the engineering workstation.\u003c/p\u003e"
                }
              ],
              "value": "The affected products insufficiently restrict runtime-supplied visualization commands, allowing local functionality on the engineering workstation to be invoked, if a user is both logged in to a CODESYS Control runtime and operates a visualization. An unauthenticated remote attacker controlling a malicious runtime and tricking a user to trust it, or performing a man-in-the-middle attack on the communication between the CODESYS Control runtime and the engineering workstation, may cause arbitrary code execution on the engineering workstation."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-669",
                  "description": "CWE-669 Incorrect Resource Transfer Between Spheres",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-11-24T07:51:36.241Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://www.certvde.com/en/advisories/VDE-2026-154/"
            }
          ],
          "source": {
            "advisory": "VDE-2026-154",
            "defect": [
              "CERT@VDE#642407"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Incorrect Resource Transfer Between Spheres in CODESYS Visualization",
          "x_generator": {
            "engine": "Vulnogram 0.4.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2026-121018",
        "datePublished": "2026-11-24T07:51:36.241Z",
        "dateReserved": "2026-11-03T08:27:12.408Z",
        "dateUpdated": "2026-11-24T16:27:46.839Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }