Search

Find a vulnerability

Search criteria ⓘ Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    600 vulnerabilities found for node.js by nodejs

    FKIE_CVE-2026-111497

    Vulnerability from fkie_nvd - Published: 2026-10-22 14:17 - Updated: 2026-11-18 19:17
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    References
    cve-coordination@google.comhttps://github.com/andybalholm/brotli/releases/tag/v1.2.7Release Notes
    cve-coordination@google.comhttps://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---highThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/23/25Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/24/6Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/26/12Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/26/13Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/10/26/16Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2026/11/03/2Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://broccoli2shell.comThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/advisories/GHSA-9v8h-qqgm-4m35Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/dotnet/announcements/issues/494Issue Tracking, Mitigation, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/google/brotli/releases/tag/v1.0.10Release Notes
    af854a3a-2127-422b-91ae-364da2661108https://github.com/google/brotli/releases/tag/v1.1.1Release Notes
    af854a3a-2127-422b-91ae-364da2661108https://github.com/google/brotli/releases/tag/v1.2.1Release Notes
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2026/10/msg00049.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://patchtheplanet.org/brotliThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497Third Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-045512.htmlThird Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-242944.htmlThird Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-443410.htmlThird Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-678870.htmlThird Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-898633.htmlThird Party Advisory
    134c704f-9b21-4f2e-91b3-4a467353bcc0https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/Third Party Advisory
    134c704f-9b21-4f2e-91b3-4a467353bcc0https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497US Government Resource
    Impacted products
    Vendor Product Version
    google brotli *
    google brotli *
    google brotli *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    python-hyper brotlicffi *
    microsoft .net *
    microsoft .net *
    microsoft .net *
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    microsoft .net 11.0.0
    debian debian_linux 12.0
    istio istio *
    istio istio *
    istio istio *
    anthropic bun *
    envoyproxy envoy *
    envoyproxy envoy *
    envoyproxy envoy *
    tianocore edk2 *
    google woff2 -
    duckdb duckdb *
    clickhouse clickhouse *
    apache arrow *
    apache arrow 27.0.0
    mcmilk 7-zip-zstd *
    7-zip p7zip *
    andybalholm brotli *
    siemens ruggedcom_ape1808_firmware -
    siemens ruggedcom_ape1808 -
    siemens common_configurator -
    siemens data_flow_monitoring *
    siemens dataxess_configurator *
    siemens edge_opc_ua_server_configurator *
    siemens flow_creator_configurator *
    siemens industrial_edge_cloud_connector_configurator *
    siemens industrial_edge_databus_configurator *
    siemens industrial_edge_hub -
    siemens industrial_edge_management_cloud -
    siemens comos_walkinside -
    siemens simatic_braumat 8.2
    siemens simatic_braumat 8.2
    siemens simatic_braumat 8.2
    siemens simatic_braumat 8.2
    siemens simatic_braumat 8.2
    siemens simatic_profiling_tool -
    siemens simatic_sistar 8.2
    siemens simatic_sistar 8.2
    siemens simatic_sistar 8.2
    siemens simatic_sistar 8.2
    siemens simatic_sistar 8.2
    siemens simatic_wincc *
    siemens simatic_wincc_companion -
    siemens simatic_wincc_runtime -
    siemens simatic_wincc_unified_for_industrial_edge -
    siemens simatic_wincc_unified_pc_runtime -
    siemens simatic_wincc_unified_siqence -
    siemens tia_administrator -
    siemens tia_project-server_web_administration_tool -
    siemens user_management_component -
    siemens hyperlynx -
    siemens innexis_architecture_native_acceleration -
    siemens insights_hub -
    siemens opcenter_connect_electronics -
    siemens opcenter_connect_manufacturing_operations_management -
    siemens opcenter_execution_core -
    siemens opcenter_execution_discrete -
    siemens opcenter_execution_foundation -
    siemens opcenter_execution_pharma -
    siemens opcenter_execution_process -
    siemens opcenter_intelligence -
    siemens opcenter_quality -
    siemens opcenter_rd\&l -
    siemens opcenter_x -
    siemens pads_professional -
    siemens pads_professional -
    siemens pave360_automotive 2026
    siemens process_preparation_x -
    siemens simcenter_executable_digital_twin -
    siemens simcenter_studio -
    siemens teamcenter 2412.0
    siemens teamcenter 2506.0
    siemens teamcenter 2512.0
    siemens teamcenter 2606.0
    siemens xpedition_designer -
    siemens xpedition_enterprise -

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "cve-coordination@google.com"
        },
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 100 NX3 M8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 100 NX3 M8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 125 NX3 M10",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet gridsave 100 \u2013 165 TL3 (HV)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC family V8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Desigo CC family V9",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Gridscale X DSA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.4",
                  "status": "affected",
                  "version": "V5.3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Gridscale X PSS\u00aeE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V36.8.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Heliox Dual Port 60kW",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Heliox Flex Pro",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Integrated PA Suite Tester",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SENTRON Powermanager V8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SENTRON Powermanager V9",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SICAM PAS CC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V6.02",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SICAM SCC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "V7.01",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SICHARGE FLEX",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SICHARGE UC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Sifinity Go",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Sifinity Setup",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "VersiCharge AC Series",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "VersiCloud",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Cloud Connector Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.24.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Common Configurator\u00a0(CC on IEM)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Common Configurator on Device\u00a0(CC on Edge)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Data Flow Monitoring",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.18",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Databus Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "DataXess Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.5.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Edge OPC UA Server Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Flow Creator Configurator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Industrial Edge Hub",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Industrial Edge Management Cloud",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "HyperLynx",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Innexis Architecture Native Acceleration 2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Insights Hub",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Connect Electronics",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Connect MOM",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Core",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Discrete",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Foundation",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Pharma",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Execution Process",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Intelligence",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Intra Plant Logistics",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter Quality",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter RDnL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Opcenter X",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "PADS Pro Essentials",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "PADS Pro Student Edition",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "PADS Professional",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "PAVE360 Automotive 2026",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Process Preparation X",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Executable Digital Twin",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Simcenter Studio",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2412",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2506",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2512",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Teamcenter V2606",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Xpedition Designer",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Xpedition Enterprise",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "COMOS Walkinside",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Project Server Web Administration Tool",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC BRAUMAT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.2 Update 5",
                  "status": "affected",
                  "version": "V8.2 Update 1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Profiling Tool",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC SISTAR",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.2 Update 5",
                  "status": "affected",
                  "version": "V8.2 Update 1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Companion",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC OA V3.20",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.20.17.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC OA V3.21",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.21.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Runtime Professional",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Unified for Industrial Edge",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Unified PC Runtime",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Unified SIQENCE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V7/V8",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "User Management Component (UMC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
        }
      ],
      "cisaActionDue": "2026-11-10",
      "cisaExploitAdd": "2026-10-27",
      "cisaRequiredAction": "Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA\u2019s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA\u2019s \u201cForensics Triage Requirements\u201d (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset\u0027s internet exposure and ensuring adherence to BOD 26-04 patching guidelines.",
      "cisaVulnerabilityName": "Google Brotli Unchecked Return Value Vulnerability",
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:google:brotli:*:*:*:*:*:-:*:*",
                  "matchCriteriaId": "8A7BE60F-21B0-4779-8D59-6E5E58C5826B",
                  "versionEndExcluding": "1.0.10",
                  "versionStartIncluding": "1.0.3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:google:brotli:*:*:*:*:*:-:*:*",
                  "matchCriteriaId": "48E72297-AFBD-4460-A732-5A6803CCCDB0",
                  "versionEndExcluding": "1.1.1",
                  "versionStartIncluding": "1.1.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:google:brotli:*:*:*:*:*:-:*:*",
                  "matchCriteriaId": "C8CA5C74-26A8-44E3-B893-1FA01CED49F5",
                  "versionEndExcluding": "1.2.1",
                  "versionStartIncluding": "1.2.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "02348F18-5E17-4427-8B78-63B4082F2FB4",
                  "versionEndExcluding": "22.23.4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "852D09BB-A396-4813-81C9-7D89D5DD5FB6",
                  "versionEndExcluding": "24.22.1",
                  "versionStartIncluding": "23.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "219CA855-3A40-42CE-BAB6-79CCFEE7746F",
                  "versionEndExcluding": "26.12.1",
                  "versionStartIncluding": "25.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:python-hyper:brotlicffi:*:*:*:*:*:python:*:*",
                  "matchCriteriaId": "E732E75B-4BEF-4D7E-8520-E03B707FB4F6",
                  "versionEndExcluding": "1.2.1.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "65DCE51C-2CD9-4179-9354-5323D28573AA",
                  "versionEndExcluding": "8.0.33",
                  "versionStartIncluding": "8.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "98654489-8C4E-4801-8728-29B01A22DEED",
                  "versionEndExcluding": "9.0.22",
                  "versionStartIncluding": "9.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "27DF5CF4-58E3-4F01-A3AA-D44B7DCC3D67",
                  "versionEndExcluding": "10.0.14",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview1:*:*:*:*:*:*",
                  "matchCriteriaId": "5DACF2FE-CF61-43E4-8A3F-F7A358DE8A01",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview2:*:*:*:*:*:*",
                  "matchCriteriaId": "280B2E64-3163-40AB-A048-14D58DEC42FD",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview3:*:*:*:*:*:*",
                  "matchCriteriaId": "12357908-3294-46EF-85A0-DA3F86C97489",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview4:*:*:*:*:*:*",
                  "matchCriteriaId": "849FC8F5-86CD-4B5D-ADFD-9CB16EA75D09",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview5:*:*:*:*:*:*",
                  "matchCriteriaId": "C86E87E2-B236-4AC9-B6C3-64B9CDEC91EB",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview6:*:*:*:*:*:*",
                  "matchCriteriaId": "9B14656E-2BB0-4B4B-B518-F3D5108253ED",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:preview7:*:*:*:*:*:*",
                  "matchCriteriaId": "E09C9DB3-F42C-4442-9CF0-24A780D094C8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:rc1:*:*:*:*:*:*",
                  "matchCriteriaId": "67035E86-61F5-421E-B243-EF64458AD8BA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:microsoft:.net:11.0.0:rc2:*:*:*:*:*:*",
                  "matchCriteriaId": "C46300CA-BA84-48B3-85C5-C20CB487C733",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:12.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "46D69DCC-AE4D-4EA5-861C-D60951444C6C",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:istio:istio:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9F01FA9D-7190-431F-84DD-24D4EBC41A2D",
                  "versionEndExcluding": "1.29.9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:istio:istio:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B8DE25CE-AFCB-4685-9836-B8EC9C820975",
                  "versionEndExcluding": "1.30.6",
                  "versionStartIncluding": "1.30.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:istio:istio:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "55EBE231-2EB8-4C9C-B279-D07F82EA5B55",
                  "versionEndExcluding": "1.31.2",
                  "versionStartIncluding": "1.31.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:anthropic:bun:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "51DD72B3-85F6-4B10-AEB4-41E0679ED0AA",
                  "versionEndExcluding": "1.4.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:envoyproxy:envoy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8EE6278D-A48A-427C-8A7E-1D4103E2ADF7",
                  "versionEndExcluding": "1.37.8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:envoyproxy:envoy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CDCA301F-83CA-4DDB-AAE4-24D5235EE2D5",
                  "versionEndExcluding": "1.38.6",
                  "versionStartIncluding": "1.38.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:envoyproxy:envoy:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B9A47DD3-2655-4722-9B9D-3888B590C82F",
                  "versionEndExcluding": "1.39.3",
                  "versionStartIncluding": "1.39.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tianocore:edk2:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C4CFCBFB-4A38-481B-93AE-7D86CCDC6FB5",
                  "versionEndIncluding": "202608",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:google:woff2:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6D1FC23A-20F7-48F7-ABB8-8D37903DFB58",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:duckdb:duckdb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0DFA4F95-92F9-4369-BE42-387520F0765B",
                  "versionEndIncluding": "2.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:clickhouse:clickhouse:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B40EE389-E2AC-4D86-91B2-79A895470317",
                  "versionEndIncluding": "26.10.2.103",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:apache:arrow:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "46A78CA5-1E4A-4DAA-B40D-387B96C1E2F9",
                  "versionEndIncluding": "26.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:apache:arrow:27.0.0:dev:*:*:*:*:*:*",
                  "matchCriteriaId": "130A7077-7885-43CB-8AFF-B6056D380156",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mcmilk:7-zip-zstd:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FB91A353-9BE9-49E7-86FD-6B5FBB291351",
                  "versionEndIncluding": "26.02-1.5.7-r2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:7-zip:p7zip:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "76A26292-08BE-459A-B25A-CA14AF8D3C29",
                  "versionEndIncluding": "16.02",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:andybalholm:brotli:*:*:*:*:*:go:*:*",
                  "matchCriteriaId": "F3E50F12-AEFE-4B4F-B474-3676F145E032",
                  "versionEndExcluding": "1.2.7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:ruggedcom_ape1808_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "37FDCA69-9049-40B4-88AF-F476901022B6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:ruggedcom_ape1808:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B89A6863-B602-4404-8D26-337FECABFFF0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:common_configurator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1F93AD0A-C29E-4FA6-A18B-1F0D03CC900C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:data_flow_monitoring:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3562BB8C-6E76-4B16-A2EF-D343EED30DA0",
                  "versionEndExcluding": "3.0.18",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:dataxess_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "076198F2-9992-4803-8377-8B264E1D7ADA",
                  "versionEndExcluding": "1.5.7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:edge_opc_ua_server_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F1122EBA-DB7C-4680-AEEF-309C95843D0D",
                  "versionEndExcluding": "2.3.10",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:flow_creator_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90BE4EB2-0B14-44F4-881D-F0DBAFCEF322",
                  "versionEndExcluding": "1.15.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:industrial_edge_cloud_connector_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D0E0C6F6-40D0-4D71-ABCE-84449C4E743A",
                  "versionEndExcluding": "1.24.3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:industrial_edge_databus_configurator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B57AD29D-69CF-4C76-AACA-3EAE3F8CBC15",
                  "versionEndExcluding": "4.0.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:industrial_edge_hub:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "70BA5718-0A9F-4B7D-9175-D6719B795363",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:industrial_edge_management_cloud:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4EA7E869-9428-4D5E-95C0-F19B6BC1BFA9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:comos_walkinside:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8C7AAED9-567F-4EE0-BC1B-F18E1109D316",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "EFA8804E-1E7E-482F-A701-B988F6C0BCE9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "A7C12A3B-925A-4219-909B-6D2D0ADA6131",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "3288CF66-F9D9-4DDD-9CAA-1EB2E075C87A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "9B3EF16B-8281-4159-ABDE-A36881CD8460",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_braumat:8.2:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "9DF55BA1-F06B-4868-AC51-15ADC8BFED3C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_profiling_tool:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0D473CE5-B139-422C-AFCF-5FBBDB2C0759",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update1:*:*:*:*:*:*",
                  "matchCriteriaId": "28A180EC-5DB8-4E8A-B063-813FA3973068",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update2:*:*:*:*:*:*",
                  "matchCriteriaId": "31122237-42B0-4B10-B33B-D6E6DEBC19B3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update3:*:*:*:*:*:*",
                  "matchCriteriaId": "2955D58B-350F-4F96-A41F-6594639403DA",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update4:*:*:*:*:*:*",
                  "matchCriteriaId": "0E95149C-B212-4670-8DFC-EEC713E87741",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_sistar:8.2:update5:*:*:*:*:*:*",
                  "matchCriteriaId": "173F36F4-23F4-4650-805F-25A9032AF64A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DA06F4BD-1512-4700-AD3E-25C6CDA60246",
                  "versionEndIncluding": "8.2",
                  "versionStartIncluding": "7.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_companion:-:*:*:*:*:-:*:*",
                  "matchCriteriaId": "174C0674-3100-4CCB-B55E-6BB1FB8F8442",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*",
                  "matchCriteriaId": "E6BFBAED-EE2B-4DE4-A76C-824DD15F4608",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_for_industrial_edge:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4DC1EDC8-DA6D-476F-9656-0FB9809F9E30",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_pc_runtime:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "49B72BEA-DE75-4A5E-8658-30E5EBBFFF69",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_unified_siqence:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E2E193FF-ED70-432A-8B33-2453A8B2B21B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:tia_administrator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FC8C7680-9033-4ECF-9764-5179A4033F64",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:tia_project-server_web_administration_tool:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "14BA6E1D-4D4E-4133-8869-5ADEC9CE545C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:user_management_component:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7139EEDB-2DCD-4C55-9DAC-423FB5807D11",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:hyperlynx:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "92D6ED26-34E3-46A6-B025-F7DC263AA75A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:innexis_architecture_native_acceleration:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BE57EA6F-BA70-409D-B037-EDD603FAC0B9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:insights_hub:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1B8E91A0-4BF0-4BDE-8F83-4FF374697A76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_connect_electronics:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0EC96381-D0C9-4949-86E7-1A1E8239A8F2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_connect_manufacturing_operations_management:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0F5FAC2-E6E0-4ECA-86B6-9D082C1D674B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_core:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0A6E1786-F0A9-498F-9DE9-F503B5DAD84A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F04BAB87-71BB-4AB4-BC42-F89616698EEF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9FE353B7-07A1-4B50-8A43-62577C2208EE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_pharma:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4CC50DA8-906E-4BD5-9861-668273EE3A76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_execution_process:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5CCA2643-1E89-49AE-B8CB-3A9CDA3031A6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_intelligence:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E3FA7CB-6931-4D0C-A3E6-1BE71EA0D30F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_quality:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9D9D89CD-FDA5-42F0-8161-3752C8AED7F3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_rd\\\u0026l:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "69EDC5E0-6CCE-4120-913C-E598E0FE2D24",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:opcenter_x:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A12051E1-2DC9-47C6-A320-927D0A7B9F47",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:pads_professional:-:*:*:*:essentials:*:*:*",
                  "matchCriteriaId": "C9033337-D032-403D-8BBF-3EA50253A40E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:pads_professional:-:*:*:*:student:*:*:*",
                  "matchCriteriaId": "F06B80D2-6A35-4AF5-A07A-0F5C3370C3E7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:pave360_automotive:2026:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B8DBFD9C-B213-4238-B39C-D4B537523CB1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:process_preparation_x:-:*:*:*:-:*:*:*",
                  "matchCriteriaId": "FEBDB60C-D759-476D-AF06-3C0691FC72CF",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simcenter_executable_digital_twin:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F6ACF933-A876-4DE5-BBA7-D5BF97DB1AB4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simcenter_studio:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B8C684EC-BECB-4833-B1F9-F773225A6172",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter:2412.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "963C8AAA-D3E0-4B10-93AE-DB15619EC5EE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter:2506.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "261C46FE-1C63-4A1F-8C8E-FC331E8F119E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter:2512.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7946C16C-5B81-42D2-BA6D-C8AA8FD5AD0C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:teamcenter:2606.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86E64B27-FE8F-45AD-BE78-219E4067F8DE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:xpedition_designer:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F52F6405-0228-4C3D-842F-839192076657",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:xpedition_enterprise:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AD525494-2807-48EA-AED0-11B9CB5A6A9B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
        }
      ],
      "id": "CVE-2026-111497",
      "lastModified": "2026-11-18T19:17:27.513",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "cvssMetricV40": [
          {
            "cvssData": {
              "Automatable": "NOT_DEFINED",
              "Recovery": "NOT_DEFINED",
              "Safety": "NOT_DEFINED",
              "attackComplexity": "LOW",
              "attackRequirements": "PRESENT",
              "attackVector": "NETWORK",
              "availabilityRequirement": "NOT_DEFINED",
              "baseScore": 9.2,
              "baseSeverity": "CRITICAL",
              "confidentialityRequirement": "NOT_DEFINED",
              "exploitMaturity": "NOT_DEFINED",
              "integrityRequirement": "NOT_DEFINED",
              "modifiedAttackComplexity": "NOT_DEFINED",
              "modifiedAttackRequirements": "NOT_DEFINED",
              "modifiedAttackVector": "NOT_DEFINED",
              "modifiedPrivilegesRequired": "NOT_DEFINED",
              "modifiedSubAvailabilityImpact": "NOT_DEFINED",
              "modifiedSubConfidentialityImpact": "NOT_DEFINED",
              "modifiedSubIntegrityImpact": "NOT_DEFINED",
              "modifiedUserInteraction": "NOT_DEFINED",
              "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
              "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
              "modifiedVulnIntegrityImpact": "NOT_DEFINED",
              "privilegesRequired": "NONE",
              "providerUrgency": "NOT_DEFINED",
              "subAvailabilityImpact": "NONE",
              "subConfidentialityImpact": "NONE",
              "subIntegrityImpact": "NONE",
              "userInteraction": "NONE",
              "valueDensity": "NOT_DEFINED",
              "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
              "version": "4.0",
              "vulnAvailabilityImpact": "HIGH",
              "vulnConfidentialityImpact": "HIGH",
              "vulnIntegrityImpact": "HIGH",
              "vulnerabilityResponseEffort": "NOT_DEFINED"
            },
            "source": "cve-coordination@google.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-111497",
              "options": [
                {
                  "exploitation": "active"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-23T00:00:00+00:00",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-10-22T14:17:37.190",
      "references": [
        {
          "source": "cve-coordination@google.com",
          "tags": [
            "Release Notes"
          ],
          "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
        },
        {
          "source": "cve-coordination@google.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://broccoli2shell.com"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking",
            "Mitigation",
            "Third Party Advisory"
          ],
          "url": "https://github.com/dotnet/announcements/issues/494"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Release Notes"
          ],
          "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Release Notes"
          ],
          "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Release Notes"
          ],
          "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://patchtheplanet.org/brotli"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
        },
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
        },
        {
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "tags": [
            "US Government Resource"
          ],
          "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
        }
      ],
      "sourceIdentifier": "cve-coordination@google.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-252"
            },
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "cve-coordination@google.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-32558

    Vulnerability from fkie_nvd - Published: 2023-09-12 02:15 - Updated: 2026-11-02 23:17
    Summary
    The use of the deprecated API `process.binding()` can bypass the permission model through path traversal. This vulnerability affects all users using the experimental permission model in Node.js 20.x. Please note that at the time this CVE was issued, the permission model is an experimental feature of Node.js.
    Impacted products
    Vendor Product Version
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Node",
              "vendor": "NodeJS",
              "versions": [
                {
                  "lessThan": "4.*",
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "5.*",
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "6.*",
                  "status": "affected",
                  "version": "6.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "7.*",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.*",
                  "status": "affected",
                  "version": "8.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "9.*",
                  "status": "affected",
                  "version": "9.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "10.*",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "11.*",
                  "status": "affected",
                  "version": "11.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "12.*",
                  "status": "affected",
                  "version": "12.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "13.*",
                  "status": "affected",
                  "version": "13.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "14.*",
                  "status": "affected",
                  "version": "14.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "15.*",
                  "status": "affected",
                  "version": "15.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "17.*",
                  "status": "affected",
                  "version": "17.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "19.*",
                  "status": "affected",
                  "version": "19.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "20.5.1",
                  "status": "affected",
                  "version": "20.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "1B1EE318-9E7D-4AF1-9FB5-245C9F8BBBE0",
                  "versionEndExcluding": "20.5.1",
                  "versionStartIncluding": "20.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The use of the deprecated API `process.binding()` can bypass the permission model through path traversal. \n\nThis vulnerability affects all users using the experimental permission model in Node.js 20.x.\n\nPlease note that at the time this CVE was issued, the permission model is an experimental feature of Node.js."
        },
        {
          "lang": "es",
          "value": "El uso de la API obsoleta `process.binding()` puede omitir el modelo de permiso a trav\u00e9s del Path Traversal. Esta vulnerabilidad afecta a todos los usuarios que utilizan el modelo de permisos experimental en Node.js 20.x. Tenga en cuenta que en el momento en que se emiti\u00f3 este CVE, el modelo de permiso es una caracter\u00edstica experimental de Node.js."
        }
      ],
      "id": "CVE-2023-32558",
      "lastModified": "2026-11-02T23:17:16.480",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-32558",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-08T21:07:36.422694Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-09-12T02:15:12.067",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://hackerone.com/reports/2051257"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://hackerone.com/reports/2051257"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20241025-0003/"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-30588

    Vulnerability from fkie_nvd - Published: 2023-11-28 20:15 - Updated: 2026-11-02 23:17
    Summary
    When an invalid public key is used to create an x509 certificate using the crypto.X509Certificate() API a non-expect termination occurs making it susceptible to DoS attacks when the attacker could force interruptions of application processing, as the process terminates when accessing public key info of provided certificates from user code. The current context of the users will be gone, and that will cause a DoS scenario. This vulnerability affects all active Node.js versions v16, v18, and, v20.
    Impacted products
    Vendor Product Version
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Node",
              "vendor": "NodeJS",
              "versions": [
                {
                  "lessThan": "4.*",
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "5.*",
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "6.*",
                  "status": "affected",
                  "version": "6.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "7.*",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.*",
                  "status": "affected",
                  "version": "8.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "9.*",
                  "status": "affected",
                  "version": "9.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "10.*",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "11.*",
                  "status": "affected",
                  "version": "11.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "12.*",
                  "status": "affected",
                  "version": "12.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "13.*",
                  "status": "affected",
                  "version": "13.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "14.*",
                  "status": "affected",
                  "version": "14.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "15.*",
                  "status": "affected",
                  "version": "15.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "16.20.1",
                  "status": "affected",
                  "version": "16.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "17.*",
                  "status": "affected",
                  "version": "17.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "18.16.1",
                  "status": "affected",
                  "version": "18.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "19.*",
                  "status": "affected",
                  "version": "19.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "20.3.1",
                  "status": "affected",
                  "version": "20.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7E7F6F9A-AF9F-453B-870D-1E8759567F29",
                  "versionEndExcluding": "16.20.1",
                  "versionStartIncluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3AA02CEF-5AC5-46F7-94DE-D9EA15678AE7",
                  "versionEndExcluding": "18.16.1",
                  "versionStartIncluding": "18.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1CAA23E6-4930-4326-9CB0-AEE5013BFD37",
                  "versionEndExcluding": "20.3.1",
                  "versionStartIncluding": "20.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "When an invalid public key is used to create an x509 certificate using the crypto.X509Certificate() API a non-expect termination occurs making it susceptible to DoS attacks when the attacker could force interruptions of application processing, as the process terminates when accessing public key info of provided certificates from user code. The current context of the users will be gone, and that will cause a DoS scenario. This vulnerability affects all active Node.js versions v16, v18, and, v20."
        },
        {
          "lang": "es",
          "value": "Cuando se utiliza una clave p\u00fablica no v\u00e1lida para crear x509 certificates utilizando la API crypto.X509Certificate(), se produce una terminaci\u00f3n no esperada que la hace susceptible a ataques DoS cuando el atacante podr\u00eda forzar interrupciones en el procesamiento de la aplicaci\u00f3n, ya que el proceso finaliza al acceder a la informaci\u00f3n de clave p\u00fablica de los certificados proporcionados desde el c\u00f3digo de usuario. El contexto actual de los usuarios desaparecer\u00e1 y eso provocar\u00e1 un escenario DoS. Esta vulnerabilidad afecta a todas las versiones activas de Node.js v16, v18 y v20."
        }
      ],
      "id": "CVE-2023-30588",
      "lastModified": "2026-11-02T23:17:16.310",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-30588",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-11-02T22:34:23.710890Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-11-28T20:15:07.437",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2023-security-releases"
        },
        {
          "source": "support@hackerone.com",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2023-security-releases"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20241101-0011/"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2026-48617

    Vulnerability from fkie_nvd - Published: 2026-06-18 17:16 - Updated: 2026-10-26 11:10
    Summary
    A flaw in Node.js Permission Model enforcement allows Bypass via `process.report.writeReport()` Path Misvalidation. This can lead to confidentiality impact or bypass of the intended security boundary under affected configurations. This vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**.
    Impacted products
    Vendor Product Version
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "22.22.3",
                  "status": "affected",
                  "version": "22.22.3",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.16.0",
                  "status": "affected",
                  "version": "24.16.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "26.3.0",
                  "status": "affected",
                  "version": "26.3.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "EBC4FE14-245C-476C-A3A1-4E7107E9394D",
                  "versionEndIncluding": "22.22.3",
                  "versionStartIncluding": "22.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "CC6AA49F-9B95-4C70-A261-E0F400C3A082",
                  "versionEndIncluding": "24.16.0",
                  "versionStartIncluding": "24.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "5127FA19-694D-4559-9A3B-D2A18B0EFC92",
                  "versionEndIncluding": "26.3.0",
                  "versionStartIncluding": "26.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js Permission Model enforcement allows Bypass via `process.report.writeReport()` Path Misvalidation. This can lead to confidentiality impact or bypass of the intended security boundary under affected configurations. This vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**."
        },
        {
          "lang": "es",
          "value": "Un fallo en el cumplimiento del Modelo de Permisos de Node.js permite la omisi\u00f3n a trav\u00e9s de la validaci\u00f3n incorrecta de la ruta de \u201cprocess.report.writeReport()\u201d. Esto puede llevar a un impacto en la confidencialidad o a la omisi\u00f3n del l\u00edmite de seguridad previsto bajo configuraciones afectadas. Esta vulnerabilidad afecta a todas las l\u00edneas de versiones compatibles: Node.js 22, Node.js 24 y Node.js 26."
        }
      ],
      "id": "CVE-2026-48617",
      "lastModified": "2026-10-26T11:10:00.157",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 1.8,
              "baseSeverity": "LOW",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.0/AV:L/AC:H/PR:H/UI:R/S:U/C:N/I:L/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 0.3,
            "impactScore": 1.4,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 8.2,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 4.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-48617",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-18T18:27:45.392825Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-06-18T17:16:31.460",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Issue Tracking",
            "Third Party Advisory"
          ],
          "url": "http://hackerone.com/reports/3692858"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2026-security-releases"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-284"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-48937

    Vulnerability from fkie_nvd - Published: 2026-06-18 19:16 - Updated: 2026-10-25 23:10
    Summary
    A flaw in Node.js HTTP/2 server API can cause servers to keep accepting data even after sending a `GOAWAY` frame. This vulnerability affects two supported release lines: **Node.js 22** and **Node.js 24**.
    Impacted products
    Vendor Product Version
    nodejs node.js *
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "22.22.3",
                  "status": "affected",
                  "version": "22.22.3",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.16.0",
                  "status": "affected",
                  "version": "24.16.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "F35F858F-EC12-428C-8ECB-6AF471D926D2",
                  "versionEndExcluding": "22.23.0",
                  "versionStartIncluding": "22.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "6E9DF5A3-6211-4D79-8D76-9910D3CF3A02",
                  "versionEndExcluding": "24.17.0",
                  "versionStartIncluding": "24.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js HTTP/2 server API can cause servers to keep accepting data even after sending a `GOAWAY` frame. This vulnerability affects two supported release lines: **Node.js 22** and **Node.js 24**."
        },
        {
          "lang": "es",
          "value": "Un defecto en la API del servidor HTTP/2 de Node.js puede hacer que los servidores sigan aceptando datos incluso despu\u00e9s de enviar un frame \u2019GOAWAY\u2019. Esta vulnerabilidad afecta a dos l\u00edneas de lanzamiento compatibles: Node.js 22 y Node.js 24."
        }
      ],
      "id": "CVE-2026-48937",
      "lastModified": "2026-10-25T23:10:00.167",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-48937",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-18T18:43:55.210236Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-06-18T19:16:23.507",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Issue Tracking",
            "Third Party Advisory"
          ],
          "url": "https://hackerone.com/reports/3658225"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2026-security-releases"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-400"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-48931

    Vulnerability from fkie_nvd - Published: 2026-06-22 20:16 - Updated: 2026-10-25 23:10
    Summary
    A flaw in Node.js HTTP Agent can cause a client to accept as valid a response that is send before the client has sent the request. This vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**.
    Impacted products
    Vendor Product Version
    nodejs node.js 22.22.3
    nodejs node.js 24.16.0
    nodejs node.js 26.3.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "22.22.3",
                  "status": "affected",
                  "version": "22.22.3",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.16.0",
                  "status": "affected",
                  "version": "24.16.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "26.3.0",
                  "status": "affected",
                  "version": "26.3.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:22.22.3:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3C0C5080-5F99-4651-9855-2DE03C9070C5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:24.16.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3B912C84-1AA5-4D74-AB1A-64162C80A33B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:26.3.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "8152ACE6-3CAF-4CA0-8B19-D4753811EB44",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js HTTP Agent can cause a client to accept as valid a response that is send before the client has sent the request.\r\n\r\nThis vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**."
        },
        {
          "lang": "es",
          "value": "Un fallo en el Agente HTTP de Node.js puede hacer que un cliente acepte como v\u00e1lida una respuesta que se env\u00eda antes de que el cliente haya enviado la solicitud.\n\nEsta vulnerabilidad afecta a todas las l\u00edneas de lanzamiento compatibles: Node.js 22, Node.js 24, y Node.js 26."
        }
      ],
      "id": "CVE-2026-48931",
      "lastModified": "2026-10-25T23:10:00.167",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 3.7,
              "baseSeverity": "LOW",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 1.4,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 3.7,
              "baseSeverity": "LOW",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-48931",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-23T14:14:24.449951Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-06-22T20:16:29.957",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2026-security-releases"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "http://www.openwall.com/lists/oss-security/2026/07/02/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Issue Tracking",
            "Third Party Advisory"
          ],
          "url": "https://github.com/nodejs/node/issues/63989"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://jdstaerk.substack.com/p/nodejs-security-fix-silently-broke"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-367"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-48619

    Vulnerability from fkie_nvd - Published: 2026-06-26 02:16 - Updated: 2026-10-25 22:10
    Summary
    A flaw in Node.js HTTP/2 client allows a server to send an unlimited number of ORIGIN frames, which could lead to an Out of Memory error on the client. This vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**.
    Impacted products
    Vendor Product Version
    nodejs node.js 22.22.3
    nodejs node.js 24.16.0
    nodejs node.js 26.3.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "22.22.3",
                  "status": "affected",
                  "version": "22.22.3",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.16.0",
                  "status": "affected",
                  "version": "24.16.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "26.3.0",
                  "status": "affected",
                  "version": "26.3.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:22.22.3:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3C0C5080-5F99-4651-9855-2DE03C9070C5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:24.16.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3B912C84-1AA5-4D74-AB1A-64162C80A33B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:26.3.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "8152ACE6-3CAF-4CA0-8B19-D4753811EB44",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js HTTP/2 client allows a server to send an unlimited number of ORIGIN frames, which could lead to an Out of Memory error on the client.\r\n\r\nThis vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**."
        },
        {
          "lang": "es",
          "value": "Un fallo en el cliente HTTP/2 de Node.js permite a un servidor enviar un n\u00famero ilimitado de tramas ORIGIN, lo que podr\u00eda provocar un error de falta de memoria en el cliente.\n\nEsta vulnerabilidad afecta a todas las l\u00edneas de versiones compatibles: Node.js 22, Node.js 24, y Node.js 26."
        }
      ],
      "id": "CVE-2026-48619",
      "lastModified": "2026-10-25T22:10:00.150",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-48619",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-26T15:01:30.143238Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-06-26T02:16:52.507",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2026-security-releases"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-400"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-48935

    Vulnerability from fkie_nvd - Published: 2026-06-26 02:16 - Updated: 2026-10-25 22:10
    Summary
    A flaw in Node.js Permission API can cause a file metadata to be modified even on a path that was set as read-only with e.g. `--allow-fs-read`. This vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**.
    Impacted products
    Vendor Product Version
    nodejs node.js 22.22.3
    nodejs node.js 24.16.0
    nodejs node.js 26.3.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "22.22.3",
                  "status": "affected",
                  "version": "22.22.3",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.16.0",
                  "status": "affected",
                  "version": "24.16.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "26.3.0",
                  "status": "affected",
                  "version": "26.3.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:22.22.3:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3C0C5080-5F99-4651-9855-2DE03C9070C5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:24.16.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3B912C84-1AA5-4D74-AB1A-64162C80A33B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:26.3.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "8152ACE6-3CAF-4CA0-8B19-D4753811EB44",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js Permission API can cause a file metadata to be modified even on a path that was set as read-only with e.g. `--allow-fs-read`.\r\n\r\nThis vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**."
        },
        {
          "lang": "es",
          "value": "Un fallo en la API de Permisos de Node.js puede provocar que los metadatos de un archivo se modifiquen incluso en una ruta que se configur\u00f3 como de solo lectura con, por ejemplo, \u201c--allow-fs-read\u201d.\n\nEsta vulnerabilidad afecta a todas las l\u00edneas de lanzamiento compatibles: Node.js 22, Node.js 24, y Node.js 26."
        }
      ],
      "id": "CVE-2026-48935",
      "lastModified": "2026-10-25T22:10:00.150",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 3.3,
              "baseSeverity": "LOW",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 1.4,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-48935",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-26T15:04:33.702023Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-06-26T02:16:53.050",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2026-security-releases"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-276"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-48928

    Vulnerability from fkie_nvd - Published: 2026-06-26 02:16 - Updated: 2026-10-25 22:10
    Summary
    A inconsistency in Node.js hostname matching can cause a trust-policy bypass in multi-context mTLS setups. This vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**.
    Impacted products
    Vendor Product Version
    nodejs node.js 22.22.3
    nodejs node.js 24.16.0
    nodejs node.js 26.3.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "22.22.3",
                  "status": "affected",
                  "version": "22.22.3",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.16.0",
                  "status": "affected",
                  "version": "24.16.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "26.3.0",
                  "status": "affected",
                  "version": "26.3.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:22.22.3:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3C0C5080-5F99-4651-9855-2DE03C9070C5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:24.16.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3B912C84-1AA5-4D74-AB1A-64162C80A33B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:26.3.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "8152ACE6-3CAF-4CA0-8B19-D4753811EB44",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A inconsistency in Node.js hostname matching can cause a trust-policy bypass in multi-context mTLS setups.\r\n\r\nThis vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**."
        },
        {
          "lang": "es",
          "value": "Una inconsistencia en la coincidencia de nombres de host de Node.js puede causar una omisi\u00f3n de la pol\u00edtica de confianza en configuraciones mTLS de m\u00faltiples contextos.\n\nEsta vulnerabilidad afecta a todas las l\u00edneas de lanzamiento compatibles: Node.js 22, Node.js 24, y Node.js 26."
        }
      ],
      "id": "CVE-2026-48928",
      "lastModified": "2026-10-25T22:10:00.150",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.2,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 1.6,
            "impactScore": 2.5,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.4,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 2.5,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-48928",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-26T13:36:17.302009Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-06-26T02:16:52.610",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2026-security-releases"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-284"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-48930

    Vulnerability from fkie_nvd - Published: 2026-06-26 02:16 - Updated: 2026-10-25 22:10
    Summary
    A flaw in Node.js TLS hostname handling can cause Embedded-nul hostnames can lead to silent authority rebinding due to c-string truncation in resolver bindings. This vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**.
    Impacted products
    Vendor Product Version
    nodejs node.js 22.22.3
    nodejs node.js 24.16.0
    nodejs node.js 26.3.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "22.22.3",
                  "status": "affected",
                  "version": "22.22.3",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.16.0",
                  "status": "affected",
                  "version": "24.16.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "26.3.0",
                  "status": "affected",
                  "version": "26.3.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:22.22.3:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3C0C5080-5F99-4651-9855-2DE03C9070C5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:24.16.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3B912C84-1AA5-4D74-AB1A-64162C80A33B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:26.3.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "8152ACE6-3CAF-4CA0-8B19-D4753811EB44",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js TLS hostname handling can cause Embedded-nul hostnames can lead to silent authority rebinding due to c-string truncation in resolver bindings.\r\n\r\nThis vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**."
        },
        {
          "lang": "es",
          "value": "Un fallo en el manejo de nombres de host TLS de Node.js puede causar que los nombres de host con nulo incrustado puedan llevar a una revinculaci\u00f3n silenciosa de autoridad debido al truncamiento de cadena C en las vinculaciones del resolvedor.\n\nEsta vulnerabilidad afecta a todas las l\u00edneas de lanzamiento compatibles: Node.js 22, Node.js 24 y Node.js 26."
        }
      ],
      "id": "CVE-2026-48930",
      "lastModified": "2026-10-25T22:10:00.150",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 5.6,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
              "version": "3.0"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 3.4,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-48930",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-26T13:37:29.781800Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-06-26T02:16:52.723",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2026-security-releases"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-284"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-48615

    Vulnerability from fkie_nvd - Published: 2026-06-26 02:16 - Updated: 2026-10-25 22:10
    Summary
    A flaw in Node.js proxy tunnel error handling could expose proxy credentials in `ERR_PROXY_TUNNEL` error messages. When proxy credentials are embedded in the proxy URL, they may be exposed through error handling paths and captured by logs, diagnostics, or other error consumers. This vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**.
    Impacted products
    Vendor Product Version
    nodejs node.js 22.22.3
    nodejs node.js 24.16.0
    nodejs node.js 26.3.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "22.22.3",
                  "status": "affected",
                  "version": "22.22.3",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.16.0",
                  "status": "affected",
                  "version": "24.16.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "26.3.0",
                  "status": "affected",
                  "version": "26.3.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:22.22.3:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3C0C5080-5F99-4651-9855-2DE03C9070C5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:24.16.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3B912C84-1AA5-4D74-AB1A-64162C80A33B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:26.3.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "8152ACE6-3CAF-4CA0-8B19-D4753811EB44",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js proxy tunnel error handling could expose proxy credentials in `ERR_PROXY_TUNNEL` error messages.\r\n\r\nWhen proxy credentials are embedded in the proxy URL, they may be exposed through error handling paths and captured by logs, diagnostics, or other error consumers.\r\n\r\nThis vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**."
        },
        {
          "lang": "es",
          "value": "Un fallo en el manejo de errores del t\u00fanel proxy de Node.js podr\u00eda exponer las credenciales del proxy en los mensajes de error \u2019ERR_PROXY_TUNNEL\u2019.\n\nCuando las credenciales del proxy est\u00e1n incrustadas en la URL del proxy, pueden ser expuestas a trav\u00e9s de rutas de manejo de errores y capturadas por registros, diagn\u00f3sticos u otros consumidores de errores.\n\nEsta vulnerabilidad afecta a todas las l\u00edneas de lanzamiento compatibles: Node.js 22, Node.js 24 y Node.js 26."
        }
      ],
      "id": "CVE-2026-48615",
      "lastModified": "2026-10-25T22:10:00.150",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 3.6,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-48615",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-26T13:34:45.532887Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-06-26T02:16:52.273",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2026-security-releases"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-359"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-48618

    Vulnerability from fkie_nvd - Published: 2026-06-26 02:16 - Updated: 2026-10-25 22:10
    Summary
    A flaw in Node.js TLS hostname handling can cause Node.js unicode dot separator handling can lead to tls wildcard-depth authentication bypass due to resolver and verifier hostname normalization mismat. This can lead to confidentiality impact or bypass of the intended security boundary under affected configurations. This vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**.
    References
    support@hackerone.comhttps://nodejs.org/en/blog/vulnerability/june-2026-security-releasesPatch, Vendor Advisory
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:28727
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:29012
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:30172
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:35841
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:35842
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:35891
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:35892
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:39246
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:39868
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:41947
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:52399
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:7378
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:9455
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/security/cve/CVE-2026-48618
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://bugzilla.redhat.com/show_bug.cgi?id=2493337
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-48618.json
    Impacted products
    Vendor Product Version
    nodejs node.js 22.22.3
    nodejs node.js 24.16.0
    nodejs node.js 26.3.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "22.22.3",
                  "status": "affected",
                  "version": "22.22.3",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.16.0",
                  "status": "affected",
                  "version": "24.16.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "26.3.0",
                  "status": "affected",
                  "version": "26.3.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        },
        {
          "affectedData": [
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/o:redhat:enterprise_linux:10.2"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs24",
              "product": "Red Hat Enterprise Linux 10",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "1:24.18.0-1.el10_2",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/o:redhat:enterprise_linux:10.2"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs22",
              "product": "Red Hat Enterprise Linux 10",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "1:22.23.1-2.el10_2",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/o:redhat:enterprise_linux_eus:10.0"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs22",
              "product": "Red Hat Enterprise Linux 10.0 Extended Update Support",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "1:22.23.1-2.el10_0",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:enterprise_linux:8"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs:24",
              "product": "Red Hat Enterprise Linux 8",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "8100020260630152626.6d880403",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:enterprise_linux:8"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs:22",
              "product": "Red Hat Enterprise Linux 8",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "8100020260703140402.6d880403",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:enterprise_linux:9"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs:24",
              "product": "Red Hat Enterprise Linux 9",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "9080020260626074955.rhel9",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:enterprise_linux:9"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs:22",
              "product": "Red Hat Enterprise Linux 9",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "9080020260626075442.rhel9",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:hummingbird:1"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs22-main",
              "product": "Red Hat Hardened Images",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "22.23.1-1.hum1",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:hummingbird:1"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs24-main",
              "product": "Red Hat Hardened Images",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "24.18.0-0.1.hum1",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:hummingbird:1"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs26-main",
              "product": "Red Hat Hardened Images",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "26.4.0-1.2.hum1",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:hummingbird:1"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs25-main",
              "product": "Red Hat Hardened Images",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "25.9.0-1.1.hum1",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:hummingbird:1"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs20-main",
              "product": "Red Hat Hardened Images",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "20.20.2-1.hum1",
                  "versionType": "rpm"
                }
              ]
            }
          ],
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:22.22.3:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3C0C5080-5F99-4651-9855-2DE03C9070C5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:24.16.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3B912C84-1AA5-4D74-AB1A-64162C80A33B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:26.3.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "8152ACE6-3CAF-4CA0-8B19-D4753811EB44",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js TLS hostname handling can cause Node.js unicode dot separator handling can lead to tls wildcard-depth authentication bypass due to resolver and verifier hostname normalization mismat.\r\n\r\nThis can lead to confidentiality impact or bypass of the intended security boundary under affected configurations.\r\n\r\nThis vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**."
        },
        {
          "lang": "es",
          "value": "Un fallo en el manejo de nombres de host TLS de Node.js puede causar que el manejo de separadores de puntos unicode de Node.js lleve a una omisi\u00f3n de autenticaci\u00f3n de profundidad de comod\u00edn TLS debido a una falta de coincidencia en la normalizaci\u00f3n de nombres de host del resolvedor y verificador.\n\nEsto puede llevar a un impacto en la confidencialidad o a la omisi\u00f3n del l\u00edmite de seguridad previsto bajo configuraciones afectadas.\n\nEsta vulnerabilidad afecta a todas las l\u00edneas de lanzamiento compatibles: Node.js 22, Node.js 24, y Node.js 26."
        }
      ],
      "id": "CVE-2026-48618",
      "lastModified": "2026-10-25T22:10:00.150",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.7,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 3.1,
            "impactScore": 4.0,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.7,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.1,
            "impactScore": 4.0,
            "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-48618",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-26T15:10:27.583362Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-06-26T02:16:52.397",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2026-security-releases"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:28727"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:29012"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:30172"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:35841"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:35842"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:35891"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:35892"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:39246"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:39868"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:41947"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:52399"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:7378"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:9455"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/security/cve/CVE-2026-48618"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2493337"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-48618.json"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-176"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-289"
            }
          ],
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-48936

    Vulnerability from fkie_nvd - Published: 2026-06-26 02:16 - Updated: 2026-10-25 22:10
    Summary
    A flaw in Node.js Permission API can cause a local server to be started (via a Unix domain socket), even without the `--allow-net` permission. This vulnerability affects one supported release line: **Node.js 26**.
    Impacted products
    Vendor Product Version
    nodejs node.js 26.3.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "26.3.0",
                  "status": "affected",
                  "version": "26.3.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:26.3.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "8152ACE6-3CAF-4CA0-8B19-D4753811EB44",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js Permission API can cause a local server to be started (via a Unix domain socket), even without the `--allow-net` permission.\r\n\r\nThis vulnerability affects one supported release line: **Node.js 26**."
        },
        {
          "lang": "es",
          "value": "Un defecto en la API de Permisos de Node.js puede provocar que se inicie un servidor local (a trav\u00e9s de un socket de dominio Unix), incluso sin el permiso \u201c--allow-net\u201d.\n\nEsta vulnerabilidad afecta a una l\u00ednea de lanzamiento compatible: Node.js 26."
        }
      ],
      "id": "CVE-2026-48936",
      "lastModified": "2026-10-25T22:10:00.150",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 3.3,
              "baseSeverity": "LOW",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 1.4,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-48936",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-26T13:35:18.745870Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-06-26T02:16:53.157",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2026-security-releases"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-284"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-48933

    Vulnerability from fkie_nvd - Published: 2026-06-26 02:16 - Updated: 2026-10-25 22:10
    Summary
    A flaw in Node.js WebCrypto implementation can crash the process if the input of `subtle.encrypt()` is a multiple of 2GiB. This vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**.
    References
    support@hackerone.comhttps://nodejs.org/en/blog/vulnerability/june-2026-security-releasesPatch, Vendor Advisory
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:28727
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:29012
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:30172
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:35841
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:35842
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:35891
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:35892
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:39246
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:39868
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:41947
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:52399
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:7378
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/errata/RHSA-2026:9455
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://access.redhat.com/security/cve/CVE-2026-48933
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://bugzilla.redhat.com/show_bug.cgi?id=2493331
    0b0ca135-0b70-47e7-9f44-1890c2a1c46chttps://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-48933.json
    Impacted products
    Vendor Product Version
    nodejs node.js 22.22.3
    nodejs node.js 24.16.0
    nodejs node.js 26.3.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "22.22.3",
                  "status": "affected",
                  "version": "22.22.3",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.16.0",
                  "status": "affected",
                  "version": "24.16.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "26.3.0",
                  "status": "affected",
                  "version": "26.3.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        },
        {
          "affectedData": [
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/o:redhat:enterprise_linux:10.2"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs24",
              "product": "Red Hat Enterprise Linux 10",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "1:24.18.0-1.el10_2",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/o:redhat:enterprise_linux:10.2"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs22",
              "product": "Red Hat Enterprise Linux 10",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "1:22.23.1-2.el10_2",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/o:redhat:enterprise_linux_eus:10.0"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs22",
              "product": "Red Hat Enterprise Linux 10.0 Extended Update Support",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "1:22.23.1-2.el10_0",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:enterprise_linux:8"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs:24",
              "product": "Red Hat Enterprise Linux 8",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "8100020260630152626.6d880403",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:enterprise_linux:8"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs:22",
              "product": "Red Hat Enterprise Linux 8",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "8100020260703140402.6d880403",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:enterprise_linux:9"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs:24",
              "product": "Red Hat Enterprise Linux 9",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "9080020260626074955.rhel9",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:enterprise_linux:9"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs:22",
              "product": "Red Hat Enterprise Linux 9",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "9080020260626075442.rhel9",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:hummingbird:1"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs22-main",
              "product": "Red Hat Hardened Images",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "22.23.1-1.hum1",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:hummingbird:1"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs24-main",
              "product": "Red Hat Hardened Images",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "24.18.0-0.1.hum1",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:hummingbird:1"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs26-main",
              "product": "Red Hat Hardened Images",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "26.4.0-1.2.hum1",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:hummingbird:1"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs25-main",
              "product": "Red Hat Hardened Images",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "25.9.0-1.1.hum1",
                  "versionType": "rpm"
                }
              ]
            },
            {
              "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
              "cpes": [
                "cpe:/a:redhat:hummingbird:1"
              ],
              "defaultStatus": "affected",
              "packageName": "nodejs20-main",
              "product": "Red Hat Hardened Images",
              "vendor": "Red Hat",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "20.20.2-1.hum1",
                  "versionType": "rpm"
                }
              ]
            }
          ],
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:22.22.3:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3C0C5080-5F99-4651-9855-2DE03C9070C5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:24.16.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3B912C84-1AA5-4D74-AB1A-64162C80A33B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:26.3.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "8152ACE6-3CAF-4CA0-8B19-D4753811EB44",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js WebCrypto implementation can crash the process if the input of `subtle.encrypt()` is a multiple of 2GiB.\r\n\r\nThis vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**."
        },
        {
          "lang": "es",
          "value": "Un fallo en la implementaci\u00f3n de WebCrypto de Node.js puede bloquear el proceso si la entrada de \u201csubtle.encrypt()\u201d es un m\u00faltiplo de 2 GiB.\n\nEsta vulnerabilidad afecta a todas las l\u00edneas de versiones compatibles: Node.js 22, Node.js 24 y Node.js 26."
        }
      ],
      "id": "CVE-2026-48933",
      "lastModified": "2026-10-25T22:10:00.150",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-48933",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-26T15:05:58.547904Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-06-26T02:16:52.833",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2026-security-releases"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:28727"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:29012"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:30172"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:35841"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:35842"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:35891"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:35892"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:39246"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:39868"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:41947"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:52399"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:7378"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/errata/RHSA-2026:9455"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://access.redhat.com/security/cve/CVE-2026-48933"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2493331"
        },
        {
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "url": "https://security.access.redhat.com/data/csaf/v2/vex/2026/cve-2026-48933.json"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-190"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-770"
            }
          ],
          "source": "0b0ca135-0b70-47e7-9f44-1890c2a1c46c",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-48934

    Vulnerability from fkie_nvd - Published: 2026-06-26 02:16 - Updated: 2026-10-25 22:10
    Summary
    A flaw in Node.js TLS host verification can cause an attacker to bypass certification validation. This vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**.
    Impacted products
    Vendor Product Version
    nodejs node.js 22.22.3
    nodejs node.js 24.16.0
    nodejs node.js 26.3.0

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "22.22.3",
                  "status": "affected",
                  "version": "22.22.3",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.16.0",
                  "status": "affected",
                  "version": "24.16.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "26.3.0",
                  "status": "affected",
                  "version": "26.3.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:22.22.3:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3C0C5080-5F99-4651-9855-2DE03C9070C5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:24.16.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3B912C84-1AA5-4D74-AB1A-64162C80A33B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:26.3.0:*:*:*:-:*:*:*",
                  "matchCriteriaId": "8152ACE6-3CAF-4CA0-8B19-D4753811EB44",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js TLS host verification can cause an attacker to bypass certification validation.\r\n\r\nThis vulnerability affects all supported release lines: **Node.js 22**, **Node.js 24**, and **Node.js 26**."
        },
        {
          "lang": "es",
          "value": "Un fallo en la verificaci\u00f3n de host TLS de Node.js puede causar que un atacante eluda la validaci\u00f3n de certificados.\n\nEsta vulnerabilidad afecta a todas las l\u00edneas de lanzamiento compatibles: Node.js 22, Node.js 24, y Node.js 26."
        }
      ],
      "id": "CVE-2026-48934",
      "lastModified": "2026-10-25T22:10:00.150",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 4.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 1.4,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-48934",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-06-26T13:35:45.737892Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-06-26T02:16:52.950",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2026-security-releases"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-295"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2023-23919

    Vulnerability from fkie_nvd - Published: 2023-02-23 20:15 - Updated: 2026-10-24 13:10
    Summary
    A cryptographic vulnerability exists in Node.js <19.2.0, <18.14.1, <16.19.1, <14.21.3 that in some cases did does not clear the OpenSSL error stack after operations that may set it. This may lead to false positive errors during subsequent cryptographic operations that happen to be on the same thread. This in turn could be used to cause a denial of service.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Node",
              "vendor": "NodeJS",
              "versions": [
                {
                  "lessThan": "4.*",
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "5.*",
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "6.*",
                  "status": "affected",
                  "version": "6.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "7.*",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.*",
                  "status": "affected",
                  "version": "8.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "9.*",
                  "status": "affected",
                  "version": "9.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "10.*",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "11.*",
                  "status": "affected",
                  "version": "11.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "12.*",
                  "status": "affected",
                  "version": "12.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "13.*",
                  "status": "affected",
                  "version": "13.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "14.21.3",
                  "status": "affected",
                  "version": "14.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "15.*",
                  "status": "affected",
                  "version": "15.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "16.19.1",
                  "status": "affected",
                  "version": "16.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "17.*",
                  "status": "affected",
                  "version": "17.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "18.14.1",
                  "status": "affected",
                  "version": "18.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "19.2.0",
                  "status": "affected",
                  "version": "19.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "428DCD7B-6F66-4F18-B780-5BD80143D482",
                  "versionEndIncluding": "14.14.0",
                  "versionStartIncluding": "14.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "DA48F3CE-68BC-43F1-9428-A9F928420081",
                  "versionEndExcluding": "14.21.3",
                  "versionStartIncluding": "14.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "1D1D0CEC-62E5-4368-B8F2-1DA5DD0B88FA",
                  "versionEndIncluding": "16.12.0",
                  "versionStartIncluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "6E9FAEC6-2D3A-4CBE-859F-11BCECC4F724",
                  "versionEndExcluding": "16.19.1",
                  "versionStartIncluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "33DB62F6-9D8D-42F8-A75E-82DA091C02BC",
                  "versionEndIncluding": "18.11.0",
                  "versionStartIncluding": "18.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "80500AD0-17C2-4698-AE03-1C6782FD38B0",
                  "versionEndExcluding": "18.14.1",
                  "versionStartIncluding": "18.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "57BCF42B-D5BC-433A-A4BA-E3014E275FA7",
                  "versionEndExcluding": "19.2.0",
                  "versionStartIncluding": "19.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A cryptographic vulnerability exists in Node.js \u003c19.2.0, \u003c18.14.1, \u003c16.19.1, \u003c14.21.3 that in some cases did does not clear the OpenSSL error stack after operations that may set it. This may lead to false positive errors during subsequent cryptographic operations that happen to be on the same thread. This in turn could be used to cause a denial of service."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad criptogr\u00e1fica existe en Node.js anterior a 19.2.0, anterior a 18.14.1, anterior a 16.19.1, anterior a 14.21.3 que en algunos casos no limpia la pila de errores de OpenSSL despu\u00e9s de operaciones que pueden establecerla. Esto puede llevar a errores de falso positivo durante operaciones criptogr\u00e1ficas subsiguientes que se ejecutan en el mismo hilo. Esto a su vez podr\u00eda usarse para causar una denegaci\u00f3n de servicio."
        }
      ],
      "id": "CVE-2023-23919",
      "lastModified": "2026-10-24T13:10:00.147",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-23919",
              "options": [
                {
                  "exploitation": "poc"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-03-12T14:26:46.934403Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-02-23T20:15:13.977",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://hackerone.com/reports/1808596"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/february-2023-security-releases/"
        },
        {
          "source": "support@hackerone.com",
          "url": "https://security.netapp.com/advisory/ntap-20230316-0008/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Third Party Advisory"
          ],
          "url": "https://hackerone.com/reports/1808596"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/february-2023-security-releases/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20230316-0008/"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-310"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-Other"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-23918

    Vulnerability from fkie_nvd - Published: 2023-02-23 20:15 - Updated: 2026-10-24 13:10
    Summary
    A privilege escalation vulnerability exists in Node.js <19.6.1, <18.14.1, <16.19.1 and <14.21.3 that made it possible to bypass the experimental Permissions (https://nodejs.org/api/permissions.html) feature in Node.js and access non authorized modules by using process.mainModule.require(). This only affects users who had enabled the experimental permissions option with --experimental-policy.
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Node",
              "vendor": "NodeJS",
              "versions": [
                {
                  "lessThan": "4.*",
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "5.*",
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "6.*",
                  "status": "affected",
                  "version": "6.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "7.*",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.*",
                  "status": "affected",
                  "version": "8.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "9.*",
                  "status": "affected",
                  "version": "9.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "10.*",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "11.*",
                  "status": "affected",
                  "version": "11.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "12.*",
                  "status": "affected",
                  "version": "12.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "13.*",
                  "status": "affected",
                  "version": "13.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "14.21.3",
                  "status": "affected",
                  "version": "14.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "15.*",
                  "status": "affected",
                  "version": "15.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "16.19.1",
                  "status": "affected",
                  "version": "16.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "17.*",
                  "status": "affected",
                  "version": "17.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "18.14.1",
                  "status": "affected",
                  "version": "18.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "19.6.1",
                  "status": "affected",
                  "version": "19.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "428DCD7B-6F66-4F18-B780-5BD80143D482",
                  "versionEndIncluding": "14.14.0",
                  "versionStartIncluding": "14.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "DA48F3CE-68BC-43F1-9428-A9F928420081",
                  "versionEndExcluding": "14.21.3",
                  "versionStartIncluding": "14.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "1D1D0CEC-62E5-4368-B8F2-1DA5DD0B88FA",
                  "versionEndIncluding": "16.12.0",
                  "versionStartIncluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "6E9FAEC6-2D3A-4CBE-859F-11BCECC4F724",
                  "versionEndExcluding": "16.19.1",
                  "versionStartIncluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "33DB62F6-9D8D-42F8-A75E-82DA091C02BC",
                  "versionEndIncluding": "18.11.0",
                  "versionStartIncluding": "18.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "80500AD0-17C2-4698-AE03-1C6782FD38B0",
                  "versionEndExcluding": "18.14.1",
                  "versionStartIncluding": "18.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "8F4FCD16-4B9F-44B9-80DD-D024759CAB10",
                  "versionEndExcluding": "19.6.1",
                  "versionStartIncluding": "19.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A privilege escalation vulnerability exists in Node.js \u003c19.6.1, \u003c18.14.1, \u003c16.19.1 and \u003c14.21.3 that made it possible to bypass the experimental Permissions (https://nodejs.org/api/permissions.html) feature in Node.js and access non authorized modules by using process.mainModule.require(). This only affects users who had enabled the experimental permissions option with --experimental-policy."
        },
        {
          "lang": "es",
          "value": "Una vulnerabilidad de escalada de privilegios existe en Node.js anterior a 19.6.1, anterior a 18.14.1, anterior a 16.19.1 y anterior a 14.21.3 que hizo posible eludir la caracter\u00edstica experimental de Permisos (https://nodejs.org/API/permissions.html) en Node.js y acceder a m\u00f3dulos no autorizados mediante el uso de process.mainModule.require(). Esto solo afecta a usuarios que hab\u00edan habilitado la opci\u00f3n de permisos experimentales con --experimental-policy."
        }
      ],
      "id": "CVE-2023-23918",
      "lastModified": "2026-10-24T13:10:00.147",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-23918",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2025-03-12T17:47:16.492191Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-02-23T20:15:13.920",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/february-2023-security-releases/"
        },
        {
          "source": "support@hackerone.com",
          "url": "https://security.netapp.com/advisory/ntap-20230316-0008/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/february-2023-security-releases/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20230316-0008/"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-863"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-863"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-58043

    Vulnerability from fkie_nvd - Published: 2026-07-30 06:25 - Updated: 2026-10-23 22:10
    Summary
    A flaw in Node.js Permission Model enforcement can over-grant filesystem access across radix-tree prefix boundaries. Under `--permission`, an attacker who is granted access to one path can abuse boundary handling to read from or write to paths outside the intended filesystem allowlist. This vulnerability affects Node.js **main**, **22.x**, **24.x**, and **26.x**.
    Impacted products
    Vendor Product Version
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "22.23.1",
                  "status": "affected",
                  "version": "22.23.1",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.18.0",
                  "status": "affected",
                  "version": "24.18.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "26.5.0",
                  "status": "affected",
                  "version": "26.5.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "5D5BDB63-A6E1-4131-8920-02D17B6E68E5",
                  "versionEndIncluding": "22.23.1",
                  "versionStartIncluding": "22.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "9354DDC1-01A6-4F46-85A8-4A21C1A41E1F",
                  "versionEndIncluding": "24.18.0",
                  "versionStartIncluding": "24.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "B2A6EA1C-9CE0-4F3F-8ED2-C3646F5DB630",
                  "versionEndIncluding": "26.5.0",
                  "versionStartIncluding": "26.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js Permission Model enforcement can over-grant filesystem access across radix-tree prefix boundaries.\r\n\r\nUnder `--permission`, an attacker who is granted access to one path can abuse boundary handling to read from or write to paths outside the intended filesystem allowlist.\r\n\r\nThis vulnerability affects Node.js **main**, **22.x**, **24.x**, and **26.x**."
        },
        {
          "lang": "es",
          "value": "Un fallo en la aplicaci\u00f3n del Modelo de Permisos de Node.js puede otorgar en exceso acceso al sistema de archivos a trav\u00e9s de los l\u00edmites de prefijo del \u00e1rbol radix.\n\nBajo \u201c--permission\u201d, un atacante a quien se le concede acceso a una ruta puede abusar del manejo de l\u00edmites para leer o escribir en rutas fuera de la lista de permitidos del sistema de archivos prevista.\n\nEsta vulnerabilidad afecta a Node.js main, 22.x, 24.x y 26.x."
        }
      ],
      "id": "CVE-2026-58043",
      "lastModified": "2026-10-23T22:10:00.160",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 1.1,
            "impactScore": 5.8,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 8.4,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.0,
            "impactScore": 5.8,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-58043",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "total"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-07-30T00:00:00+00:00",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-07-30T06:25:55.310",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/july-2026-security-releases"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-284"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-56850

    Vulnerability from fkie_nvd - Published: 2026-07-30 06:25 - Updated: 2026-10-23 22:10
    Summary
    A flaw in Node.js HTTPS Agent connection reuse can cause PFX object-array key collisions, allowing mutual TLS (mTLS) client identities to be reused across requests configured with different client certificates. This vulnerability affects Node.js **26.x**, **24.x**, and **22.x**.
    Impacted products
    Vendor Product Version
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "26.5.0",
                  "status": "affected",
                  "version": "26.5.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.18.0",
                  "status": "affected",
                  "version": "24.18.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "22.23.1",
                  "status": "affected",
                  "version": "22.23.1",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "5D5BDB63-A6E1-4131-8920-02D17B6E68E5",
                  "versionEndIncluding": "22.23.1",
                  "versionStartIncluding": "22.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "9354DDC1-01A6-4F46-85A8-4A21C1A41E1F",
                  "versionEndIncluding": "24.18.0",
                  "versionStartIncluding": "24.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "B2A6EA1C-9CE0-4F3F-8ED2-C3646F5DB630",
                  "versionEndIncluding": "26.5.0",
                  "versionStartIncluding": "26.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js HTTPS Agent connection reuse can cause PFX object-array key collisions, allowing mutual TLS (mTLS) client identities to be reused across requests configured with different client certificates.\r\n\r\nThis vulnerability affects Node.js **26.x**, **24.x**, and **22.x**."
        },
        {
          "lang": "es",
          "value": "Un fallo en la reutilizaci\u00f3n de conexiones del Agente HTTPS de Node.js puede causar colisiones de claves de array de objetos PFX, permitiendo que las identidades de cliente de TLS mutuo (mTLS) sean reutilizadas entre solicitudes configuradas con diferentes certificados de cliente.\n\nEsta vulnerabilidad afecta a Node.js 26.x, 24.x, y 22.x."
        }
      ],
      "id": "CVE-2026-56850",
      "lastModified": "2026-10-23T22:10:00.160",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 4.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 0.5,
            "impactScore": 3.6,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 4.4,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "HIGH",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 0.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-56850",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-07-30T12:37:02.406813Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-07-30T06:25:55.073",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/july-2026-security-releases"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-287"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2026-56847

    Vulnerability from fkie_nvd - Published: 2026-07-30 06:25 - Updated: 2026-10-23 22:10
    Summary
    A flaw in Node.js Permission Model enforcement allows `trace_events.createTracing().enable()` Writes Trace Logs Outside `--allow-fs-write`. This can lead to confidentiality impact or bypass of the intended security boundary under affected configurations. This vulnerability affects Node.js **22.x**, **24.x**, and **26.x**.
    Impacted products
    Vendor Product Version
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "node",
              "vendor": "nodejs",
              "versions": [
                {
                  "lessThanOrEqual": "26.5.0",
                  "status": "affected",
                  "version": "26.5.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "24.18.0",
                  "status": "affected",
                  "version": "24.18.0",
                  "versionType": "semver"
                },
                {
                  "lessThanOrEqual": "22.23.1",
                  "status": "affected",
                  "version": "22.23.1",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "5D5BDB63-A6E1-4131-8920-02D17B6E68E5",
                  "versionEndIncluding": "22.23.1",
                  "versionStartIncluding": "22.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "9354DDC1-01A6-4F46-85A8-4A21C1A41E1F",
                  "versionEndIncluding": "24.18.0",
                  "versionStartIncluding": "24.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "B2A6EA1C-9CE0-4F3F-8ED2-C3646F5DB630",
                  "versionEndIncluding": "26.5.0",
                  "versionStartIncluding": "26.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw in Node.js Permission Model enforcement allows `trace_events.createTracing().enable()` Writes Trace Logs Outside `--allow-fs-write`.\r\n\r\nThis can lead to confidentiality impact or bypass of the intended security boundary under affected configurations.\r\n\r\nThis vulnerability affects Node.js **22.x**, **24.x**, and **26.x**."
        },
        {
          "lang": "es",
          "value": "Un fallo en la aplicaci\u00f3n del Modelo de Permisos de Node.js permite que \u2019trace_events.createTracing().enable()\u2019 escriba registros de trazas fuera de \u2019--allow-fs-write\u2019.\n\nEsto puede llevar a un impacto en la confidencialidad o a la elusi\u00f3n del l\u00edmite de seguridad previsto bajo configuraciones afectadas.\n\nEsta vulnerabilidad afecta a Node.js 22.x, 24.x, y 26.x."
        }
      ],
      "id": "CVE-2026-56847",
      "lastModified": "2026-10-23T22:10:00.160",
      "metrics": {
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 3.3,
              "baseSeverity": "LOW",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 1.4,
            "source": "support@hackerone.com",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 6.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 4.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2026-56847",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-07-30T12:34:51.815184Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2026-07-30T06:25:54.953",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/july-2026-security-releases"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Analyzed",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-1119"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2018-12115

    Vulnerability from fkie_nvd - Published: 2018-08-21 12:29 - Updated: 2026-10-15 18:17
    Summary
    In all versions of Node.js prior to 6.14.4, 8.11.4 and 10.9.0 when used with UCS-2 encoding (recognized by Node.js under the names `'ucs2'`, `'ucs-2'`, `'utf16le'` and `'utf-16le'`), `Buffer#write()` can be abused to write outside of the bounds of a single `Buffer`. Writes that start from the second-to-last position of a buffer cause a miscalculation of the maximum length of the input bytes to be written.
    References
    cve-request@iojs.orghttp://www.securityfocus.com/bid/105127Third Party Advisory, VDB Entry
    cve-request@iojs.orghttps://access.redhat.com/errata/RHSA-2018:2552Third Party Advisory
    cve-request@iojs.orghttps://access.redhat.com/errata/RHSA-2018:2553Third Party Advisory
    cve-request@iojs.orghttps://access.redhat.com/errata/RHSA-2018:2944Third Party Advisory
    cve-request@iojs.orghttps://access.redhat.com/errata/RHSA-2018:2949Third Party Advisory
    cve-request@iojs.orghttps://access.redhat.com/errata/RHSA-2018:3537Third Party Advisory
    cve-request@iojs.orghttps://nodejs.org/en/blog/vulnerability/august-2018-security-releases/Vendor Advisory
    cve-request@iojs.orghttps://security.gentoo.org/glsa/202003-48
    af854a3a-2127-422b-91ae-364da2661108http://www.securityfocus.com/bid/105127Third Party Advisory, VDB Entry
    af854a3a-2127-422b-91ae-364da2661108https://access.redhat.com/errata/RHSA-2018:2552Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://access.redhat.com/errata/RHSA-2018:2553Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://access.redhat.com/errata/RHSA-2018:2944Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://access.redhat.com/errata/RHSA-2018:2949Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://access.redhat.com/errata/RHSA-2018:3537Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://nodejs.org/en/blog/vulnerability/august-2018-security-releases/Vendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.gentoo.org/glsa/202003-48
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "Node.js",
              "vendor": "The Node.js Project",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions of Node.js prior to 6.14.4, 8.11.4 and 10.9.0"
                }
              ]
            }
          ],
          "source": "cve-request@iojs.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4F608F84-5A94-4DC1-A7B8-E19028F96A40",
                  "versionEndExcluding": "6.14.4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "468A9D35-95E1-473B-A5D3-9BD78818F599",
                  "versionEndExcluding": "8.11.4",
                  "versionStartIncluding": "8.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "48A01678-361E-4F23-B7D6-41B0C145F491",
                  "versionEndExcluding": "10.9.0",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:redhat:openshift_container_platform:3.11:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2F87326E-0B56-4356-A889-73D026DB1D4B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "In all versions of Node.js prior to 6.14.4, 8.11.4 and 10.9.0 when used with UCS-2 encoding (recognized by Node.js under the names `\u0027ucs2\u0027`, `\u0027ucs-2\u0027`, `\u0027utf16le\u0027` and `\u0027utf-16le\u0027`), `Buffer#write()` can be abused to write outside of the bounds of a single `Buffer`. Writes that start from the second-to-last position of a buffer cause a miscalculation of the maximum length of the input bytes to be written."
        },
        {
          "lang": "es",
          "value": "En todas las versiones de Node.js anteriores a la 6.14.4, 8.11.4 y 10.9.0, cuando se utiliza con codificaci\u00f3n UCS-2 (reconocida por Node.js bajo los nombres \"ucs2\", \"ucs-2\", \"utf16le\" y \"utf-16le\"), se puede explotar \"Buffer#write()\" para escribir fuera de los l\u00edmites de un b\u00fafer. Las escrituras que empiezan desde la segunda hasta la \u00faltima posici\u00f3n de un b\u00fafer provocan un error de c\u00e1lculo de la longitud m\u00e1xima de los bytes de entrada que se van a escribir."
        }
      ],
      "id": "CVE-2018-12115",
      "lastModified": "2026-10-15T18:17:11.007",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2018-12115",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "no"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-15T17:22:23.692025Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2018-08-21T12:29:00.210",
      "references": [
        {
          "source": "cve-request@iojs.org",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/105127"
        },
        {
          "source": "cve-request@iojs.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:2552"
        },
        {
          "source": "cve-request@iojs.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:2553"
        },
        {
          "source": "cve-request@iojs.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:2944"
        },
        {
          "source": "cve-request@iojs.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:2949"
        },
        {
          "source": "cve-request@iojs.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:3537"
        },
        {
          "source": "cve-request@iojs.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/august-2018-security-releases/"
        },
        {
          "source": "cve-request@iojs.org",
          "url": "https://security.gentoo.org/glsa/202003-48"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://www.securityfocus.com/bid/105127"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:2552"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:2553"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:2944"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:2949"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2018:3537"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/august-2018-security-releases/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.gentoo.org/glsa/202003-48"
        }
      ],
      "sourceIdentifier": "cve-request@iojs.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "cve-request@iojs.org",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2022-0778

    Vulnerability from fkie_nvd - Published: 2022-03-15 17:15 - Updated: 2026-10-14 13:17
    Summary
    The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc).
    References
    openssl-security@openssl.orghttp://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.htmlThird Party Advisory, VDB Entry
    openssl-security@openssl.orghttp://seclists.org/fulldisclosure/2022/May/33Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://seclists.org/fulldisclosure/2022/May/35Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://seclists.org/fulldisclosure/2022/May/38Mailing List, Third Party Advisory
    openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdfThird Party Advisory
    openssl-security@openssl.orghttps://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65
    openssl-security@openssl.orghttps://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83
    openssl-security@openssl.orghttps://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246
    openssl-security@openssl.orghttps://lists.debian.org/debian-lts-announce/2022/03/msg00023.htmlMailing List, Third Party Advisory
    openssl-security@openssl.orghttps://lists.debian.org/debian-lts-announce/2022/03/msg00024.htmlMailing List, Third Party Advisory
    openssl-security@openssl.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/
    openssl-security@openssl.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/
    openssl-security@openssl.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/
    openssl-security@openssl.orghttps://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002Third Party Advisory
    openssl-security@openssl.orghttps://security.gentoo.org/glsa/202210-02Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20220321-0002/Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20220429-0005/Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20240621-0006/
    openssl-security@openssl.orghttps://support.apple.com/kb/HT213255Third Party Advisory
    openssl-security@openssl.orghttps://support.apple.com/kb/HT213256Third Party Advisory
    openssl-security@openssl.orghttps://support.apple.com/kb/HT213257Third Party Advisory
    openssl-security@openssl.orghttps://www.debian.org/security/2022/dsa-5103Third Party Advisory
    openssl-security@openssl.orghttps://www.openssl.org/news/secadv/20220315.txtVendor Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuapr2022.htmlThird Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2022-06Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2022-07Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2022-08Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2022-09Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.htmlThird Party Advisory, VDB Entry
    af854a3a-2127-422b-91ae-364da2661108http://seclists.org/fulldisclosure/2022/May/33Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://seclists.org/fulldisclosure/2022/May/35Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://seclists.org/fulldisclosure/2022/May/38Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdfThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65
    af854a3a-2127-422b-91ae-364da2661108https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83
    af854a3a-2127-422b-91ae-364da2661108https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2022/03/msg00023.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2022/03/msg00024.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/
    af854a3a-2127-422b-91ae-364da2661108https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.gentoo.org/glsa/202210-02Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20220321-0002/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20220429-0005/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20240621-0006/
    af854a3a-2127-422b-91ae-364da2661108https://support.apple.com/kb/HT213255Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://support.apple.com/kb/HT213256Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://support.apple.com/kb/HT213257Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.debian.org/security/2022/dsa-5103Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.openssl.org/news/secadv/20220315.txtVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuapr2022.htmlThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2022-06Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2022-07Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2022-08Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2022-09Third Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-019200.html
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-028723.html
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-108696.html
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-398330.html
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-712929.html

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1)"
                },
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m)"
                },
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc)"
                }
              ]
            }
          ],
          "source": "openssl-security@openssl.org"
        },
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "BFCClient",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.17",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Industrial Edge - OPC UA Connector",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.7.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Industrial Edge - SIMATIC S7 Connector App",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.7.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "OpenPCS 7 V8.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "OpenPCS 7 V9.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "OpenPCS 7 V9.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM CROSSBOW Station Access Controller (SAC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM RM1224 LTE(4G) EU",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM RM1224 LTE(4G) NAM",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX MX5000",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX MX5000RE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1400",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1500",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1501",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1510",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1511",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1512",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1524",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX1536",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "RUGGEDCOM ROX RX5000",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.15.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE LPE9403",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0 HF0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M804PB",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M812-1 ADSL-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M812-1 ADSL-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M816-1 ADSL-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M816-1 ADSL-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M826-2 SHDSL-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M874-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M874-3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M876-3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M876-3 (ROK)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M876-4",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M876-4 (EU)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE M876-4 (NAM)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE MUM853-1 (EU)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE MUM856-1 (EU)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE MUM856-1 (RoW)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE S615 EEC LAN-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE S615 LAN-Router",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE SC622-2C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE SC632-2C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE SC636-2C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE SC642-2C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE SC646-2C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1748-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1748-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1750D (JP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.7.1.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1750D (ROW)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.7.1.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1750D (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V8.7.1.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1788-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1788-2 EEC M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1788-2 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W1788-2IA M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W721-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W721-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W721-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W721-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W722-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W722-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W722-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W722-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W722-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W722-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45 (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W734-1 RJ45 (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W738-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W738-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W738-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W738-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W748-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W761-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W761-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W761-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W761-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45 (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W774-1 RJ45 (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12 EEC (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W778-1 M12 EEC (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 SFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 SFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 SFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2 SFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2IA RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2IA RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2IA RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W786-2IA RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-1 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 M12 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE W788-2 RJ45",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WAM763-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WAM766-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WAM766-1 (US)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WAM766-1 EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WAM766-1 EEC (US)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WUM763-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WUM763-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WUM766-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE WUM766-1 (USA)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X200-4P IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X201-3P IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X201-3P IRT PRO",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X202-2IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X202-2IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X202-2P IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X202-2P IRT PRO",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204-2FM",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204-2LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204-2LD TS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204-2TS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X204IRT PRO",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X206-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X206-1LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X208",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X208PRO",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X212-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X212-2LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X216",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X224",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (230V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (24V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (2x 230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X302-7 EEC (2x 24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X304-2FE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X306-1LD FE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (230V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (24V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (2x 230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-2 EEC (2x 24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-3LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X307-3LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2 RD (inkl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2LD",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2LH",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2LH",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2LH+",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2LH+",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2M",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2M",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2M PoE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2M PoE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2M TS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X308-2M TS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X310",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X310",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X310FE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X310FE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X320-1 FE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X320-1-2LD FE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE X408-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB205-3 (SC, PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB205-3 (ST, E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB205-3 (ST, E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB205-3 (ST, PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB205-3LD (SC, E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB205-3LD (SC, PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB208 (E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB208 (PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB213-3 (SC, E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB213-3 (SC, PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB213-3 (ST, E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB213-3 (ST, PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB213-3LD (SC, E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB213-3LD (SC, PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB216 (E/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XB216 (PN)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2 (SC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2 (ST/BFOC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2G PoE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2G PoE (54 V DC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2G PoE EEC (54 V DC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2SFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2SFP EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2SFP G",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2SFP G (EIP DEF.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC206-2SFP G EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208G",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208G (EIP def.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208G EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208G PoE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC208G PoE (54 V DC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216-3G PoE",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216-3G PoE (54 V DC)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216-4C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216-4C G",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216-4C G (EIP Def.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216-4C G EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC216EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC224",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC224-4C G",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC224-4C G (EIP Def.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XC224-4C G EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF201-3P IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF202-2P IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204 DNA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204-2BA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204-2BA DNA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204-2BA IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF204IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF206-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XF208",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XM408-4C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XM408-4C (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XM408-8C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XM408-8C (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XM416-4C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XM416-4C (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP208",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP208 (Ethernet/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP208EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP208PoE EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP216",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP216 (Ethernet/IP)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP216EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XP216POE EEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (230V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (230V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (230V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (230V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M (24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M TS (24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-12M TS (24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.1.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324WG (24 x FE, AC 230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR324WG (24 X FE, DC 24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR326-2C PoE WG",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR326-2C PoE WG (without UL)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR524-8C, 1x230V",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR524-8C, 1x230V (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR524-8C, 24V",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR524-8C, 24V (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR524-8C, 2x230V",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR524-8C, 2x230V (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR526-8C, 1x230V",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR526-8C, 1x230V (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR526-8C, 24V",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR526-8C, 24V (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR526-8C, 2x230V",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR526-8C, 2x230V (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR528-6M",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR528-6M (2HR2, L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR528-6M (2HR2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR528-6M (L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR552-12M",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR552-12M (2HR2, L3 int.)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR552-12M (2HR2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SCALANCE XR552-12M (2HR2)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V6.5.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Security Configuration Tool (SCT)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Cloud Connect 7 CC712",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.9.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Cloud Connect 7 CC716",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.9.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1242-7 V2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1243-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1243-7 LTE EU",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1243-7 LTE US",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1243-8 IRC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1542SP-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.2.28",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1543-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.37",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1543SP-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.2.28",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1545-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.1.80",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1626",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 1628",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 343-1 Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 443-1 Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC CP 443-1 OPC UA",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Drive Controller CPU 1504D TF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Drive Controller CPU 1507D TF",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1510SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1510SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1510SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1510SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1512SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1512SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1512SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP CPU 1512SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V21.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC HMI Unified Comfort Panels family",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V18.0 Update 0 SR0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Logon V1.6",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.6 Upd6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV540 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 H",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV550 S",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 U",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC MV560 X",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC NET PC Software V14",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC NET PC Software V15",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC NET PC Software V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V16 Update 6",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC NET PC Software V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 SP1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS 7 TeleControl",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V9.1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS 7 V8.2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS 7 V9.0",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS 7 V9.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V9.1 SP2 UC04",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PCS neo (Administration Console)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC PDM",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V9.2 SP2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC Process Historian OPC UA Server",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2020 SP1 Update 1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF166C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF185C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF186C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF186CI",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF188C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF188CI",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF360R",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF610R",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF615R",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF650R",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF680R",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC RF685R",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.0.1.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1211C AC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1211C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1211C DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1212C AC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1212C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1212C DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1212FC DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1212FC DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1214C AC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1214C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1214C DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1214FC DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1214FC DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1215C AC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1215C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1215C DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1215FC DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1215FC DC/DC/Rly",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1200 CPU 1217C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511T-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1513R-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515R-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515T-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1517H-3 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 Software Controller V2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V21.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-PLCSIM Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC STEP 7 V5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.7 HF4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC Unified (TIA Portal)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17.0.0.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V7.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V7.4",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.4 SP1 Update 22",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC WinCC V7.5",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V7.5 SP2 Update 16",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOCODE ES V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOCODE ES V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOCODE ES V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.1",
                  "status": "affected",
                  "version": "V5.1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION SCOUT TIA V5.3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMOTION SCOUT TIA V5.4",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS DCC V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS DCC V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS Startdrive V15.1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS Startdrive V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAMICS Startdrive V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAUT Software ST7sc",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINAUT ST7CC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC INS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.0 SP2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEC NMS",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.0 SP3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SINEMA Remote Connect Server",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.2.28",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.2.28",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET CP 1242-7 V2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET CP 1543-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.37",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET CP 343-1 Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET CP 443-1 Advanced",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.3.11",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET SCALANCE X202-2P IRT",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V5.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET SCALANCE XC206-2",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET SCALANCE XC206-2SFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET SCALANCE XC208",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS NET SCALANCE XC216-4C",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.4",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CP 1243-1",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CP 1243-1 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.4.29",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212 AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212C AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214 AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214 DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214C DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214FC DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1214FC DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215C AC/DC/RLY",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215C DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1200 CPU 1215FC DC/DC/DC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V4.6.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1515R-2 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.9.7",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1517H-3 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.0.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS TIM 1531 IRC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.4.8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIRIUS Safety ES V17 (TIA Portal)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIRIUS Soft Starter ES V15.1 (TIA Portal)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIRIUS Soft Starter ES V16 (TIA Portal)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIRIUS Soft Starter ES V17 (TIA Portal)",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V17 Update 5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TeleControl Server Basic V3",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TIA Administrator",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V1.0.8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TIA Portal Cloud V16",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TIA Portal Cloud V17",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "TIM 1531 IRC",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V2.4.8",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F3BC593C-D7BB-42A8-9488-BE910A8C3B68",
                  "versionEndExcluding": "1.0.2zd",
                  "versionStartIncluding": "1.0.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "16D7B14C-9D04-40AC-9FCE-73D3DF468DB2",
                  "versionEndExcluding": "1.1.1n",
                  "versionStartIncluding": "1.1.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7225F27-E0BC-4716-AF68-8D68EE90F7CE",
                  "versionEndExcluding": "3.0.2",
                  "versionStartIncluding": "3.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:11.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FA6FEEC2-9F11-4643-8827-749718254FED",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:clustered_data_ontap:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1FE996B1-6951-4F85-AA58-B99A379D2163",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:clustered_data_ontap_antivirus_connector:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "62347994-1353-497C-9C4A-D5D8D95F67E8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "361B791A-D336-4431-8F68-8135BEFFAEA2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:storagegrid:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8ADFF451-740F-4DBA-BD23-3881945D3E40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:a250_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1236B66D-EB11-4324-929F-E2B86683C3C7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:a250:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "281DFC67-46BB-4FC2-BE03-3C65C9311F65",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netapp:500f_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ECF32BB1-9A58-4821-AE49-5D5C8200631F",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netapp:500f:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F21DE67F-CDFD-4D36-9967-633CD0240C6F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A930E247-0B43-43CB-98FF-6CE7B8189835",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:36:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C675112-476C-4D7C-BCB9-A2FB2D0BC9FD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1188273E-D496-41A9-AE16-75C0EB70EFB2",
                  "versionEndExcluding": "8.15.4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "644DD241-261E-41A3-86B5-C0834502EA81",
                  "versionEndExcluding": "10.1.2",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mariadb:mariadb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "49CFE4A3-DDFC-4801-8C68-510EB5CFBC36",
                  "versionEndExcluding": "10.2.42",
                  "versionStartIncluding": "10.2.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mariadb:mariadb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F8EB13E9-AFD7-4E82-A471-61201460CAC4",
                  "versionEndExcluding": "10.3.33",
                  "versionStartIncluding": "10.3.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mariadb:mariadb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3EFE42EF-DB07-4DD4-A40C-6DD6A7D1E6DC",
                  "versionEndExcluding": "10.4.23",
                  "versionStartIncluding": "10.4.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mariadb:mariadb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E3C63CE6-6B86-4C48-8D30-DC74CA83C5EC",
                  "versionEndExcluding": "10.5.14",
                  "versionStartIncluding": "10.5.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mariadb:mariadb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "09ADA35C-125F-4970-ACB7-36A9CC3516BF",
                  "versionEndExcluding": "10.6.6",
                  "versionStartIncluding": "10.6.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mariadb:mariadb:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E0435104-B0F9-4997-A769-36821689DF45",
                  "versionEndExcluding": "10.7.2",
                  "versionStartIncluding": "10.7.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "564ED5C8-50D7-413A-B88E-E62B6C07336A",
                  "versionEndIncluding": "12.12.0",
                  "versionStartIncluding": "12.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "274A9803-2997-4E65-BDB0-8B5C23120CD1",
                  "versionEndExcluding": "12.22.11",
                  "versionStartIncluding": "12.13.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "05678B4E-5F27-4096-8E9B-38B84A7E7793",
                  "versionEndIncluding": "14.14.0",
                  "versionStartExcluding": "14.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "CECEE1EE-B2A2-476B-82AE-48DFF6F1729A",
                  "versionEndExcluding": "14.19.1",
                  "versionStartIncluding": "14.15.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "DC9C8402-7102-4BCF-8A49-CFDF1C59B92F",
                  "versionEndIncluding": "16.12.0",
                  "versionStartExcluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "3DF34038-6987-4196-B5E7-FF5656D1EE5A",
                  "versionEndExcluding": "16.14.2",
                  "versionStartIncluding": "16.13.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "0AD8D8BB-702C-4FDF-A0A2-872744B8BF68",
                  "versionEndExcluding": "17.7.2",
                  "versionStartExcluding": "17.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli. Internally this function is used when parsing certificates that contain elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. It is possible to trigger the infinite loop by crafting a certificate that has invalid explicit curve parameters. Since certificate parsing happens prior to verification of the certificate signature, any process that parses an externally supplied certificate may thus be subject to a denial of service attack. The infinite loop can also be reached when parsing crafted private keys as they can contain explicit elliptic curve parameters. Thus vulnerable situations include: - TLS clients consuming server certificates - TLS servers consuming client certificates - Hosting providers taking certificates or private keys from customers - Certificate authorities parsing certification requests from subscribers - Anything else which parses ASN.1 elliptic curve parameters Also any other applications that use the BN_mod_sqrt() where the attacker can control the parameter values are vulnerable to this DoS issue. In the OpenSSL 1.0.2 version the public key is not parsed during initial parsing of the certificate which makes it slightly harder to trigger the infinite loop. However any operation which requires the public key from the certificate will trigger the infinite loop. In particular the attacker can use a self-signed certificate to trigger the loop during verification of the certificate signature. This issue affects OpenSSL versions 1.0.2, 1.1.1 and 3.0. It was addressed in the releases of 1.1.1n and 3.0.2 on the 15th March 2022. Fixed in OpenSSL 3.0.2 (Affected 3.0.0,3.0.1). Fixed in OpenSSL 1.1.1n (Affected 1.1.1-1.1.1m). Fixed in OpenSSL 1.0.2zd (Affected 1.0.2-1.0.2zc)."
        },
        {
          "lang": "es",
          "value": "La funci\u00f3n BN_mod_sqrt(), que calcula una ra\u00edz cuadrada modular, contiene un error que puede causar un bucle eterno para m\u00f3dulos no primos. Internamente, esta funci\u00f3n es usado cuando son analizados certificados que contienen claves p\u00fablicas de curva el\u00edptica en forma comprimida o par\u00e1metros de curva el\u00edptica expl\u00edcitos con un punto base codificado en forma comprimida. Es posible desencadenar el bucle infinito si es dise\u00f1ado un certificado con par\u00e1metros de curva expl\u00edcitos no v\u00e1lidos. Dado que el an\u00e1lisis del certificado es realizado antes de la verificaci\u00f3n de la firma del certificado, cualquier proceso que analice un certificado suministrado externamente puede ser objeto de un ataque de denegaci\u00f3n de servicio. El bucle infinito tambi\u00e9n puede alcanzarse cuando son analizadas claves privadas dise\u00f1adas, ya que pueden contener par\u00e1metros expl\u00edcitos de la curva el\u00edptica. Por lo tanto, las situaciones vulnerables incluyen: - Clientes TLS que consumen certificados de servidor - Servidores TLS que consumen certificados de cliente - Proveedores de hosting que toman certificados o claves privadas de clientes - Autoridades de certificaci\u00f3n que analizan peticiones de certificaci\u00f3n de suscriptores - Cualquier otra cosa que analice par\u00e1metros de curva el\u00edptica ASN.1 Tambi\u00e9n cualquier otra aplicaci\u00f3n que utilice BN_mod_sqrt() donde el atacante pueda controlar los valores de los par\u00e1metros es vulnerable a este problema de DoS. En OpenSSL versi\u00f3n 1.0.2, la clave p\u00fablica no es analizada durante el an\u00e1lisis inicial del certificado, lo que dificulta ligeramente la activaci\u00f3n del bucle infinito. Sin embargo, cualquier operaci\u00f3n que requiera la clave p\u00fablica del certificado desencadenar\u00e1 el bucle infinito. En particular, el atacante puede usar un certificado autofirmado para desencadenar el bucle durante la verificaci\u00f3n de la firma del certificado. Este problema afecta a OpenSSL versiones 1.0.2, 1.1.1 y 3.0. Fue abordado en las versiones 1.1.1n y 3.0.2 del 15 de marzo de 2022. Corregido en OpenSSL versi\u00f3n 3.0.2 (Afectado 3.0.0,3.0.1). Corregido en OpenSSL versi\u00f3n 1.1.1n (Afectado 1.1.1-1.1.1m). Corregido en OpenSSL versi\u00f3n 1.0.2zd (Afectado 1.0.2-1.0.2zc)"
        }
      ],
      "id": "CVE-2022-0778",
      "lastModified": "2026-10-14T13:17:14.377",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2022-0778",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-05-22T13:27:14.476267Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-03-15T17:15:08.513",
      "references": [
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/May/33"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/May/35"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/May/38"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdf"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00023.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00024.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202210-02"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220321-0002/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220429-0005/"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://support.apple.com/kb/HT213255"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://support.apple.com/kb/HT213256"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://support.apple.com/kb/HT213257"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2022/dsa-5103"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.openssl.org/news/secadv/20220315.txt"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-06"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-07"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-08"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-09"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory",
            "VDB Entry"
          ],
          "url": "http://packetstormsecurity.com/files/167344/OpenSSL-1.0.2-1.1.1-3.0-BN_mod_sqrt-Infinite-Loop.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/May/33"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/May/35"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://seclists.org/fulldisclosure/2022/May/38"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-712929.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=3118eb64934499d93db3230748a452351d1d9a65"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=380085481c64de749a6dd25cdf0bcf4360b30f83"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=a466912611aa6cbdf550cd10601390e587451246"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00023.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/03/msg00024.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/323SNN6ZX7PRJJWP2BUAFLPUAE42XWLZ/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GDB3GQVJPXJE7X5C5JN6JAA4XUDWD6E6/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/W6K3PR542DXWLEFFMFIDMME4CWMHJRMG/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0002"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202210-02"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220321-0002/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220429-0005/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://support.apple.com/kb/HT213255"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://support.apple.com/kb/HT213256"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://support.apple.com/kb/HT213257"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2022/dsa-5103"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.openssl.org/news/secadv/20220315.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-06"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-07"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-08"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2022-09"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-019200.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-028723.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-108696.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-398330.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html"
        }
      ],
      "sourceIdentifier": "openssl-security@openssl.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-835"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-835"
            }
          ],
          "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "type": "Secondary"
        }
      ]
    }

    FKIE_CVE-2020-10531

    Vulnerability from fkie_nvd - Published: 2020-03-12 19:15 - Updated: 2026-10-14 09:17
    Summary
    An issue was discovered in International Components for Unicode (ICU) for C/C++ through 66.1. An integer overflow, leading to a heap-based buffer overflow, exists in the UnicodeString::doAppend() function in common/unistr.cpp.
    References
    cve@mitre.orghttp://lists.opensuse.org/opensuse-security-announce/2020-04/msg00004.htmlMailing List, Third Party Advisory
    cve@mitre.orghttps://access.redhat.com/errata/RHSA-2020:0738Third Party Advisory
    cve@mitre.orghttps://bugs.chromium.org/p/chromium/issues/detail?id=1044570Permissions Required, Third Party Advisory
    cve@mitre.orghttps://chromereleases.googleblog.com/2020/02/stable-channel-update-for-desktop_24.htmlThird Party Advisory
    cve@mitre.orghttps://chromium.googlesource.com/chromium/deps/icu/+/9f4020916eb1f28f3666f018fdcbe6c9a37f0e08Patch, Third Party Advisory
    cve@mitre.orghttps://github.com/unicode-org/icu/commit/b7d08bc04a4296982fcef8b6b8a354a9e4e7afcaPatch, Third Party Advisory
    cve@mitre.orghttps://github.com/unicode-org/icu/pull/971Issue Tracking, Patch, Third Party Advisory
    cve@mitre.orghttps://lists.debian.org/debian-lts-announce/2020/03/msg00024.htmlMailing List, Third Party Advisory
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/4OOYAMJVLLCLXDTHW3V5UXNULZBBK4O6/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/6IOHSO6BUKC6I66J5PZOMAGFVJ66ZS57/
    cve@mitre.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/X3B5RWJQD5LA45MYLLR55KZJOJ5NVZGP/
    cve@mitre.orghttps://security.gentoo.org/glsa/202003-15Third Party Advisory
    cve@mitre.orghttps://unicode-org.atlassian.net/browse/ICU-20958Permissions Required, Third Party Advisory
    cve@mitre.orghttps://usn.ubuntu.com/4305-1/Third Party Advisory
    cve@mitre.orghttps://www.debian.org/security/2020/dsa-4646Third Party Advisory
    cve@mitre.orghttps://www.oracle.com//security-alerts/cpujul2021.htmlNot Applicable, Third Party Advisory
    cve@mitre.orghttps://www.oracle.com/security-alerts/cpuapr2022.htmlThird Party Advisory
    cve@mitre.orghttps://www.oracle.com/security-alerts/cpujan2021.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://lists.opensuse.org/opensuse-security-announce/2020-04/msg00004.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://access.redhat.com/errata/RHSA-2020:0738Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://bugs.chromium.org/p/chromium/issues/detail?id=1044570Permissions Required, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://chromereleases.googleblog.com/2020/02/stable-channel-update-for-desktop_24.htmlThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://chromium.googlesource.com/chromium/deps/icu/+/9f4020916eb1f28f3666f018fdcbe6c9a37f0e08Patch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/unicode-org/icu/commit/b7d08bc04a4296982fcef8b6b8a354a9e4e7afcaPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://github.com/unicode-org/icu/pull/971Issue Tracking, Patch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2020/03/msg00024.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/4OOYAMJVLLCLXDTHW3V5UXNULZBBK4O6/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/6IOHSO6BUKC6I66J5PZOMAGFVJ66ZS57/
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/X3B5RWJQD5LA45MYLLR55KZJOJ5NVZGP/
    af854a3a-2127-422b-91ae-364da2661108https://security.gentoo.org/glsa/202003-15Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://unicode-org.atlassian.net/browse/ICU-20958Permissions Required, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://usn.ubuntu.com/4305-1/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.debian.org/security/2020/dsa-4646Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com//security-alerts/cpujul2021.htmlNot Applicable, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuapr2022.htmlThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpujan2021.htmlPatch, Third Party Advisory
    0b142b55-0307-4c5a-b3c9-f314f3fb7c5ehttps://cert-portal.siemens.com/productcert/html/ssa-398330.html

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "source": "cve@mitre.org"
        },
        {
          "affectedData": [
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "V3.1.5",
                  "status": "affected",
                  "version": "V3.1.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:icu-project:international_components_for_unicode:*:*:*:*:*:c\\/c\\+\\+:*:*",
                  "matchCriteriaId": "2894DF6A-AC41-4844-8DA4-B9322993B699",
                  "versionEndIncluding": "66.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:redhat:enterprise_linux_desktop:6.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EE249E1B-A1FD-4E08-AA71-A0E1F10FFE97",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:redhat:enterprise_linux_server:6.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9BBCD86A-E6C7-4444-9D74-F861084090F0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:redhat:enterprise_linux_workstation:6.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E5ED5807-55B7-47C5-97A6-03233F4FBC3A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:google:chrome:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D165035A-62F6-4ADC-A3B4-1FD602E03D84",
                  "versionEndExcluding": "80.0.3987.122",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:30:*:*:*:*:*:*:*",
                  "matchCriteriaId": "97A4B8DF-58DA-4AB6-A1F9-331B36409BA3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:31:*:*:*:*:*:*:*",
                  "matchCriteriaId": "80F0FA5D-8D3B-4C0E-81E2-87998286AF33",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:33:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E460AA51-FCDA-46B9-AE97-E6676AA5E194",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:8.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C11E6FB0-C8C0-4527-9AA0-CB9B316F8F43",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:12.04:*:*:*:-:*:*:*",
                  "matchCriteriaId": "CB66DB75-2B16-4EBF-9B93-CE49D8086E41",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:14.04:*:*:*:esm:*:*:*",
                  "matchCriteriaId": "815D70A8-47D3-459C-A32C-9FEACA0659D1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:esm:*:*:*",
                  "matchCriteriaId": "7A5301BF-1402-4BE0-A0F8-69FBE79BC6D6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "23A7C53F-B80F-4E6A-AFA9-58EEA84BE11D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:canonical:ubuntu_linux:19.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A31C8344-3E02-4EB8-8BD8-4C84B7959624",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:opensuse:leap:15.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B620311B-34A3-48A6-82DF-6F078D7A4493",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:oracle:banking_extensibility_workbench:14.3.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EABAFD73-150F-4DFE-B721-29EB4475D979",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:banking_extensibility_workbench:14.4.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DE57039D-E2EE-4014-A7B1-D7380D26098E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "25A3180B-21AF-4010-9DAB-41ADFD2D8031",
                  "versionEndIncluding": "10.12.0",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "E9E9BD86-6374-45B3-8727-AACED7C8F3B9",
                  "versionEndExcluding": "10.21.0",
                  "versionStartIncluding": "10.13.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in International Components for Unicode (ICU) for C/C++ through 66.1. An integer overflow, leading to a heap-based buffer overflow, exists in the UnicodeString::doAppend() function in common/unistr.cpp."
        },
        {
          "lang": "es",
          "value": "Se detect\u00f3 un problema en International Components for Unicode (ICU) para C/C++ versiones hasta 66.1. Se presenta un desbordamiento de enteros, conllevando a un desbordamiento de b\u00fafer en la regi\u00f3n heap de la memoria, en la funci\u00f3n UnicodeString::doAppend() en el archivo common/unistr.cpp."
        }
      ],
      "id": "CVE-2020-10531",
      "lastModified": "2026-10-14T09:17:16.753",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 6.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": true
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-03-12T19:15:13.227",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-04/msg00004.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2020:0738"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://bugs.chromium.org/p/chromium/issues/detail?id=1044570"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://chromereleases.googleblog.com/2020/02/stable-channel-update-for-desktop_24.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://chromium.googlesource.com/chromium/deps/icu/+/9f4020916eb1f28f3666f018fdcbe6c9a37f0e08"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://github.com/unicode-org/icu/commit/b7d08bc04a4296982fcef8b6b8a354a9e4e7afca"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Issue Tracking",
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://github.com/unicode-org/icu/pull/971"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2020/03/msg00024.html"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/4OOYAMJVLLCLXDTHW3V5UXNULZBBK4O6/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/6IOHSO6BUKC6I66J5PZOMAGFVJ66ZS57/"
        },
        {
          "source": "cve@mitre.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/X3B5RWJQD5LA45MYLLR55KZJOJ5NVZGP/"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202003-15"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://unicode-org.atlassian.net/browse/ICU-20958"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://usn.ubuntu.com/4305-1/"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2020/dsa-4646"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Not Applicable",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "cve@mitre.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujan2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://lists.opensuse.org/opensuse-security-announce/2020-04/msg00004.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://access.redhat.com/errata/RHSA-2020:0738"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://bugs.chromium.org/p/chromium/issues/detail?id=1044570"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://chromereleases.googleblog.com/2020/02/stable-channel-update-for-desktop_24.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://chromium.googlesource.com/chromium/deps/icu/+/9f4020916eb1f28f3666f018fdcbe6c9a37f0e08"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://github.com/unicode-org/icu/commit/b7d08bc04a4296982fcef8b6b8a354a9e4e7afca"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Issue Tracking",
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://github.com/unicode-org/icu/pull/971"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2020/03/msg00024.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/4OOYAMJVLLCLXDTHW3V5UXNULZBBK4O6/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/6IOHSO6BUKC6I66J5PZOMAGFVJ66ZS57/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/X3B5RWJQD5LA45MYLLR55KZJOJ5NVZGP/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202003-15"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Permissions Required",
            "Third Party Advisory"
          ],
          "url": "https://unicode-org.atlassian.net/browse/ICU-20958"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://usn.ubuntu.com/4305-1/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2020/dsa-4646"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Not Applicable",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujan2021.html"
        },
        {
          "source": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-398330.html"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-190"
            },
            {
              "lang": "en",
              "value": "CWE-787"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-30590

    Vulnerability from fkie_nvd - Published: 2023-11-28 20:15 - Updated: 2026-10-08 22:17
    Summary
    The generateKeys() API function returned from crypto.createDiffieHellman() only generates missing (or outdated) keys, that is, it only generates a private key if none has been set yet, but the function is also needed to compute the corresponding public key after calling setPrivateKey(). However, the documentation says this API call: "Generates private and public Diffie-Hellman key values". The documented behavior is very different from the actual behavior, and this difference could easily lead to security issues in applications that use these APIs as the DiffieHellman may be used as the basis for application-level security, implications are consequently broad.
    Impacted products
    Vendor Product Version
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Node",
              "vendor": "NodeJS",
              "versions": [
                {
                  "lessThan": "4.*",
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "5.*",
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "6.*",
                  "status": "affected",
                  "version": "6.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "7.*",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.*",
                  "status": "affected",
                  "version": "8.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "9.*",
                  "status": "affected",
                  "version": "9.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "10.*",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "11.*",
                  "status": "affected",
                  "version": "11.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "12.*",
                  "status": "affected",
                  "version": "12.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "13.*",
                  "status": "affected",
                  "version": "13.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "14.*",
                  "status": "affected",
                  "version": "14.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "15.*",
                  "status": "affected",
                  "version": "15.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "16.20.1",
                  "status": "affected",
                  "version": "16.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "17.*",
                  "status": "affected",
                  "version": "17.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "18.16.1",
                  "status": "affected",
                  "version": "18.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "19.*",
                  "status": "affected",
                  "version": "19.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "20.3.1",
                  "status": "affected",
                  "version": "20.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7E7F6F9A-AF9F-453B-870D-1E8759567F29",
                  "versionEndExcluding": "16.20.1",
                  "versionStartIncluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3AA02CEF-5AC5-46F7-94DE-D9EA15678AE7",
                  "versionEndExcluding": "18.16.1",
                  "versionStartIncluding": "18.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1CAA23E6-4930-4326-9CB0-AEE5013BFD37",
                  "versionEndExcluding": "20.3.1",
                  "versionStartIncluding": "20.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The generateKeys() API function returned from crypto.createDiffieHellman() only generates missing (or outdated) keys, that is, it only generates a private key if none has been set yet, but the function is also needed to compute the corresponding public key after calling setPrivateKey(). However, the documentation says this API call: \"Generates private and public Diffie-Hellman key values\".\n\nThe documented behavior is very different from the actual behavior, and this difference could easily lead to security issues in applications that use these APIs as the DiffieHellman may be used as the basis for application-level security, implications are consequently broad."
        },
        {
          "lang": "es",
          "value": "La funci\u00f3n API generateKeys() devuelta por crypto.createDiffieHellman() solo genera claves faltantes (o desactualizadas), es decir, solo genera una clave privada si a\u00fan no se ha configurado ninguna, pero la funci\u00f3n tambi\u00e9n es necesaria para calcular la clave p\u00fablica correspondiente. despu\u00e9s de llamar a setPrivateKey(). Sin embargo, la documentaci\u00f3n dice que esta llamada API: \"Genera valores de clave Diffie-Hellman p\u00fablicos y privados\". El comportamiento documentado es muy diferente del comportamiento real, y esta diferencia podr\u00eda conducir f\u00e1cilmente a problemas de seguridad en las aplicaciones que utilizan estas API, ya que DiffieHellman puede usarse como base para la seguridad a nivel de aplicaci\u00f3n; en consecuencia, las implicaciones son amplias."
        }
      ],
      "id": "CVE-2023-30590",
      "lastModified": "2026-10-08T22:17:24.300",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-30590",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-08T21:06:29.230574Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-11-28T20:15:07.480",
      "references": [
        {
          "source": "support@hackerone.com",
          "url": "https://lists.debian.org/debian-lts-announce/2024/03/msg00029.html"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2023-security-releases"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2024/03/msg00029.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2024/09/msg00029.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2023-security-releases"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20241101-0011/"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-Other"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-30589

    Vulnerability from fkie_nvd - Published: 2023-07-01 00:15 - Updated: 2026-10-08 22:17
    Summary
    The llhttp parser in the http module in Node v20.2.0 does not strictly use the CRLF sequence to delimit HTTP requests. This can lead to HTTP Request Smuggling (HRS). The CR character (without LF) is sufficient to delimit HTTP header fields in the llhttp parser. According to RFC7230 section 3, only the CRLF sequence should delimit each header-field. This impacts all Node.js active versions: v16, v18, and, v20
    References
    support@hackerone.comhttps://hackerone.com/reports/2001873Exploit, Issue Tracking, Third Party Advisory
    support@hackerone.comhttps://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/HMEELCREWMRT6NS7HWXLA6XFLLMO36HE/Mailing List
    support@hackerone.comhttps://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/IV326O2X4BE3SINX5FJHMAKVHUAA4ZYF/Patch, Third Party Advisory
    support@hackerone.comhttps://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/UEJWL67XR67JAGEL2ZK22NA3BRKNMZNY/Mailing List
    support@hackerone.comhttps://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VCVG4TQRGTK4LKAZKVEQAUEJM7DUACYE/Patch, Third Party Advisory
    support@hackerone.comhttps://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VEEQIN5242K5NBE2CZ4DYTNA5B4YTYE5/Mailing List
    support@hackerone.comhttps://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VKFMKD4MJZIKFQJAAJ4VZ2FHIJ764A76/Mailing List
    support@hackerone.comhttps://security.netapp.com/advisory/ntap-20230803-0009/Third Party Advisory
    support@hackerone.comhttps://security.netapp.com/advisory/ntap-20240621-0006/
    af854a3a-2127-422b-91ae-364da2661108https://hackerone.com/reports/2001873Exploit, Issue Tracking, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2024/09/msg00029.html
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/HMEELCREWMRT6NS7HWXLA6XFLLMO36HE/Mailing List
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/IV326O2X4BE3SINX5FJHMAKVHUAA4ZYF/Patch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/UEJWL67XR67JAGEL2ZK22NA3BRKNMZNY/Mailing List
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VCVG4TQRGTK4LKAZKVEQAUEJM7DUACYE/Patch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VEEQIN5242K5NBE2CZ4DYTNA5B4YTYE5/Mailing List
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VKFMKD4MJZIKFQJAAJ4VZ2FHIJ764A76/Mailing List
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20230803-0009/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20240621-0006/
    Impacted products

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Node",
              "vendor": "NodeJS",
              "versions": [
                {
                  "lessThan": "4.*",
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "5.*",
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "6.*",
                  "status": "affected",
                  "version": "6.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "7.*",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.*",
                  "status": "affected",
                  "version": "8.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "9.*",
                  "status": "affected",
                  "version": "9.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "10.*",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "11.*",
                  "status": "affected",
                  "version": "11.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "12.*",
                  "status": "affected",
                  "version": "12.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "13.*",
                  "status": "affected",
                  "version": "13.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "14.*",
                  "status": "affected",
                  "version": "14.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "15.*",
                  "status": "affected",
                  "version": "15.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "16.20.1",
                  "status": "affected",
                  "version": "16.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "17.*",
                  "status": "affected",
                  "version": "17.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "18.16.1",
                  "status": "affected",
                  "version": "18.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "19.*",
                  "status": "affected",
                  "version": "19.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "20.3.1",
                  "status": "affected",
                  "version": "20.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "C5D7BC2C-D9AF-4048-9D36-55BF7CB6632B",
                  "versionEndExcluding": "16.20.1",
                  "versionStartIncluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "5C30F3E9-6CB7-4616-824E-A97BB69FB7E3",
                  "versionEndExcluding": "18.16.1",
                  "versionStartIncluding": "18.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "220A3D52-0B69-438A-B042-F19694CC63F1",
                  "versionEndExcluding": "20.3.1",
                  "versionStartIncluding": "20.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:37:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E30D0E6F-4AE8-4284-8716-991DFA48CC5D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:38:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CC559B26-5DFC-4B7A-A27C-B77DE755DFF9",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "The llhttp parser in the http module in Node v20.2.0 does not strictly use the CRLF sequence to delimit HTTP requests. This can lead to HTTP Request Smuggling (HRS).\r\n\r\nThe CR character (without LF) is sufficient to delimit HTTP header fields in the llhttp parser. According to RFC7230 section 3, only the CRLF sequence should delimit each header-field. This impacts all Node.js active versions: v16, v18, and, v20"
        }
      ],
      "id": "CVE-2023-30589",
      "lastModified": "2026-10-08T22:17:24.087",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-30589",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-08T21:06:26.378931Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-07-01T00:15:10.293",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Exploit",
            "Issue Tracking",
            "Third Party Advisory"
          ],
          "url": "https://hackerone.com/reports/2001873"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Mailing List"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/HMEELCREWMRT6NS7HWXLA6XFLLMO36HE/"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/IV326O2X4BE3SINX5FJHMAKVHUAA4ZYF/"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Mailing List"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/UEJWL67XR67JAGEL2ZK22NA3BRKNMZNY/"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VCVG4TQRGTK4LKAZKVEQAUEJM7DUACYE/"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Mailing List"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VEEQIN5242K5NBE2CZ4DYTNA5B4YTYE5/"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Mailing List"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VKFMKD4MJZIKFQJAAJ4VZ2FHIJ764A76/"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20230803-0009/"
        },
        {
          "source": "support@hackerone.com",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Issue Tracking",
            "Third Party Advisory"
          ],
          "url": "https://hackerone.com/reports/2001873"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.debian.org/debian-lts-announce/2024/09/msg00029.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/HMEELCREWMRT6NS7HWXLA6XFLLMO36HE/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/IV326O2X4BE3SINX5FJHMAKVHUAA4ZYF/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/UEJWL67XR67JAGEL2ZK22NA3BRKNMZNY/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VCVG4TQRGTK4LKAZKVEQAUEJM7DUACYE/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VEEQIN5242K5NBE2CZ4DYTNA5B4YTYE5/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/VKFMKD4MJZIKFQJAAJ4VZ2FHIJ764A76/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20230803-0009/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-Other"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2023-30585

    Vulnerability from fkie_nvd - Published: 2023-11-28 02:15 - Updated: 2026-10-08 22:17
    Summary
    A vulnerability has been identified in the Node.js (.msi version) installation process, specifically affecting Windows users who install Node.js using the .msi installer. This vulnerability emerges during the repair operation, where the "msiexec.exe" process, running under the NT AUTHORITY\SYSTEM context, attempts to read the %USERPROFILE% environment variable from the current user's registry. The issue arises when the path referenced by the %USERPROFILE% environment variable does not exist. In such cases, the "msiexec.exe" process attempts to create the specified path in an unsafe manner, potentially leading to the creation of arbitrary folders in arbitrary locations. The severity of this vulnerability is heightened by the fact that the %USERPROFILE% environment variable in the Windows registry can be modified by standard (or "non-privileged") users. Consequently, unprivileged actors, including malicious entities or trojans, can manipulate the environment variable key to deceive the privileged "msiexec.exe" process. This manipulation can result in the creation of folders in unintended and potentially malicious locations. It is important to note that this vulnerability is specific to Windows users who install Node.js using the .msi installer. Users who opt for other installation methods are not affected by this particular issue.
    Impacted products
    Vendor Product Version
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Node",
              "vendor": "NodeJS",
              "versions": [
                {
                  "lessThan": "4.*",
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "5.*",
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "6.*",
                  "status": "affected",
                  "version": "6.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "7.*",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.*",
                  "status": "affected",
                  "version": "8.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "9.*",
                  "status": "affected",
                  "version": "9.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "10.*",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "11.*",
                  "status": "affected",
                  "version": "11.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "12.*",
                  "status": "affected",
                  "version": "12.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "13.*",
                  "status": "affected",
                  "version": "13.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "14.*",
                  "status": "affected",
                  "version": "14.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "15.*",
                  "status": "affected",
                  "version": "15.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "16.20.1",
                  "status": "affected",
                  "version": "16.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "17.*",
                  "status": "affected",
                  "version": "17.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "18.16.1",
                  "status": "affected",
                  "version": "18.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "19.*",
                  "status": "affected",
                  "version": "19.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "20.3.1",
                  "status": "affected",
                  "version": "20.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7E7F6F9A-AF9F-453B-870D-1E8759567F29",
                  "versionEndExcluding": "16.20.1",
                  "versionStartIncluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3AA02CEF-5AC5-46F7-94DE-D9EA15678AE7",
                  "versionEndExcluding": "18.16.1",
                  "versionStartIncluding": "18.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1CAA23E6-4930-4326-9CB0-AEE5013BFD37",
                  "versionEndExcluding": "20.3.1",
                  "versionStartIncluding": "20.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in the Node.js (.msi version) installation process, specifically affecting Windows users who install Node.js using the .msi installer. This vulnerability emerges during the repair operation, where the \"msiexec.exe\" process, running under the NT AUTHORITY\\SYSTEM context, attempts to read the %USERPROFILE% environment variable from the current user\u0027s registry.\n\nThe issue arises when the path referenced by the %USERPROFILE% environment variable does not exist. In such cases, the \"msiexec.exe\" process attempts to create the specified path in an unsafe manner, potentially leading to the creation of arbitrary folders in arbitrary locations.\n\nThe severity of this vulnerability is heightened by the fact that the %USERPROFILE% environment variable in the Windows registry can be modified by standard (or \"non-privileged\") users. Consequently, unprivileged actors, including malicious entities or trojans, can manipulate the environment variable key to deceive the privileged \"msiexec.exe\" process. This manipulation can result in the creation of folders in unintended and potentially malicious locations.\n\nIt is important to note that this vulnerability is specific to Windows users who install Node.js using the .msi installer. Users who opt for other installation methods are not affected by this particular issue."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en el proceso de instalaci\u00f3n de Node.js (versi\u00f3n .msi), que afecta espec\u00edficamente a los usuarios de Windows que instalan Node.js utilizando el instalador .msi. Esta vulnerabilidad surge durante la operaci\u00f3n de reparaci\u00f3n, donde el proceso \"msiexec.exe\", que se ejecuta en el contexto NT AUTHORITY\\SYSTEM, intenta leer la variable de entorno %USERPROFILE% del registro del usuario actual. El problema surge cuando la ruta a la que hace referencia la variable de entorno %USERPROFILE% no existe. En tales casos, el proceso \"msiexec.exe\" intenta crear la ruta especificada de forma insegura, lo que podr\u00eda provocar la creaci\u00f3n de carpetas arbitrarias en ubicaciones arbitrarias. La gravedad de esta vulnerabilidad se ve aumentada por el hecho de que los usuarios est\u00e1ndar (o \"sin privilegios\") pueden modificar la variable de entorno %USERPROFILE% en el registro de Windows. En consecuencia, los actores no privilegiados, incluidas entidades maliciosas o troyanos, pueden manipular la clave de la variable de entorno para enga\u00f1ar al proceso privilegiado \"msiexec.exe\". Esta manipulaci\u00f3n puede dar como resultado la creaci\u00f3n de carpetas en ubicaciones no deseadas y potencialmente maliciosas. Es importante tener en cuenta que esta vulnerabilidad es espec\u00edfica de los usuarios de Windows que instalan Node.js utilizando el instalador .msi. Los usuarios que optan por otros m\u00e9todos de instalaci\u00f3n no se ven afectados por este problema en particular."
        }
      ],
      "id": "CVE-2023-30585",
      "lastModified": "2026-10-08T22:17:23.563",
      "metrics": {
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2023-30585",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-08T21:08:04.211982Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2023-11-28T02:15:42.077",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2023-security-releases"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/june-2023-security-releases"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20241101-0011/"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "NVD-CWE-noinfo"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-44533

    Vulnerability from fkie_nvd - Published: 2022-02-24 19:15 - Updated: 2026-10-08 22:17
    Summary
    Node.js < 12.22.9, < 14.18.3, < 16.13.2, and < 17.3.1 did not handle multi-value Relative Distinguished Names correctly. Attackers could craft certificate subjects containing a single-value Relative Distinguished Name that would be interpreted as a multi-value Relative Distinguished Name, for example, in order to inject a Common Name that would allow bypassing the certificate subject verification.Affected versions of Node.js that do not accept multi-value Relative Distinguished Names and are thus not vulnerable to such attacks themselves. However, third-party code that uses node's ambiguous presentation of certificate subjects may be vulnerable.

    {
      "affected": [
        {
          "affectedData": [
            {
              "defaultStatus": "unaffected",
              "product": "Node",
              "vendor": "NodeJS",
              "versions": [
                {
                  "lessThan": "4.*",
                  "status": "affected",
                  "version": "4.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "5.*",
                  "status": "affected",
                  "version": "5.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "6.*",
                  "status": "affected",
                  "version": "6.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "7.*",
                  "status": "affected",
                  "version": "7.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "8.*",
                  "status": "affected",
                  "version": "8.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "9.*",
                  "status": "affected",
                  "version": "9.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "10.*",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "11.*",
                  "status": "affected",
                  "version": "11.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "12.22.9",
                  "status": "affected",
                  "version": "12.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "13.*",
                  "status": "affected",
                  "version": "13.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "14.18.3",
                  "status": "affected",
                  "version": "14.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "15.*",
                  "status": "affected",
                  "version": "15.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "16.13.2",
                  "status": "affected",
                  "version": "16.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "17.3.1",
                  "status": "affected",
                  "version": "17.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "source": "support@hackerone.com"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "DAE16BC9-7B14-48DA-ADEB-D1898E0B9885",
                  "versionEndExcluding": "12.22.9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "8499B085-A803-4958-BB99-8E7FABB177BB",
                  "versionEndExcluding": "14.18.3",
                  "versionStartIncluding": "14.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "113157AB-0571-4244-A857-ADE4F4EA1F11",
                  "versionEndExcluding": "16.13.2",
                  "versionStartIncluding": "16.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "9DF5B801-BC99-4F91-B350-C14A5998532C",
                  "versionEndExcluding": "17.3.1",
                  "versionStartIncluding": "17.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:20.3.5:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "079F2588-2746-408B-9BB0-9A569289985B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:21.3.1:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "51600424-E294-41E0-9C8B-12D0C3456027",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:22.0.0.2:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "C3D12B98-032F-49A6-B237-E0CAD32D9A25",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_cluster:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2C122D22-D058-4395-8D18-A031B4157968",
                  "versionEndExcluding": "8.0.29",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_cluster:8.0.29:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3FF59ECA-F63D-4DD5-A4B4-CD31731C0CC2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_connectors:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "727AE4B8-ECED-4942-B378-AC869D39D8D0",
                  "versionEndIncluding": "8.0.28",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_enterprise_monitor:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0EBAC6D-D0CE-42A1-AEA0-2D50C8035747",
                  "versionEndIncluding": "8.0.29",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "361CAD5F-8866-44CC-A47E-C0E98A9FAABA",
                  "versionEndIncluding": "5.7.37",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3D713546-8144-491B-B3D9-FBE437E4A442",
                  "versionEndIncluding": "8.0.28",
                  "versionStartIncluding": "8.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_workbench:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7BDC629D-CC4C-4903-8A06-BF5823457996",
                  "versionEndIncluding": "8.0.28",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.58:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D9DB4A14-2EF5-4B54-95D2-75E6CF9AA0A9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.59:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C8AF00C6-B97F-414D-A8DF-057E6BFD8597",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:11.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FA6FEEC2-9F11-4643-8827-749718254FED",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "Node.js \u003c 12.22.9, \u003c 14.18.3, \u003c 16.13.2, and \u003c 17.3.1 did not handle multi-value Relative Distinguished Names correctly. Attackers could craft certificate subjects containing a single-value Relative Distinguished Name that would be interpreted as a multi-value Relative Distinguished Name, for example, in order to inject a Common Name that would allow bypassing the certificate subject verification.Affected versions of Node.js that do not accept multi-value Relative Distinguished Names and are thus not vulnerable to such attacks themselves. However, third-party code that uses node\u0027s ambiguous presentation of certificate subjects may be vulnerable."
        },
        {
          "lang": "es",
          "value": "Node.js versiones anteriores a 12.22.9, versiones anteriores a 14.18.3, versiones anteriores a 16.13.2, y versiones anteriores a 17.3.1, no manejaba correctamente los Nombres Distinguidos Relativos de varios valores. Los atacantes podr\u00edan dise\u00f1ar sujetos de certificados que contengan un Nombre Distinguido Relativo de un solo valor que ser\u00eda interpretado como un Nombre Distinguido Relativo de varios valores, por ejemplo, para inyectar un Nombre Com\u00fan que permitir\u00eda omitir la verificaci\u00f3n del sujeto del certificado. Las versiones afectadas de Node.js que no aceptan Nombres Distinguidos Relativos de varios valores y, por lo tanto, no son vulnerables a tales ataques por s\u00ed mismas. Sin embargo, el c\u00f3digo de terceros que usa la presentaci\u00f3n ambigua de sujetos de certificados de Node puede ser vulnerable"
        }
      ],
      "id": "CVE-2021-44533",
      "lastModified": "2026-10-08T22:17:13.950",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 5.0,
              "confidentialityImpact": "NONE",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.3,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 1.4,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-44533",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-08T21:15:41.447359Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2022-02-24T19:15:09.407",
      "references": [
        {
          "source": "support@hackerone.com",
          "tags": [
            "Exploit",
            "Mitigation",
            "Third Party Advisory"
          ],
          "url": "https://hackerone.com/reports/1429694"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Release Notes",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/jan-2022-security-releases/"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220325-0007/"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2022/dsa-5170"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "support@hackerone.com",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Exploit",
            "Mitigation",
            "Third Party Advisory"
          ],
          "url": "https://hackerone.com/reports/1429694"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Release Notes",
            "Vendor Advisory"
          ],
          "url": "https://nodejs.org/en/blog/vulnerability/jan-2022-security-releases/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220325-0007/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2022/dsa-5170"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        }
      ],
      "sourceIdentifier": "support@hackerone.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-295"
            }
          ],
          "source": "support@hackerone.com",
          "type": "Secondary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-295"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    FKIE_CVE-2021-3449

    Vulnerability from fkie_nvd - Published: 2021-03-25 15:15 - Updated: 2026-10-08 22:17
    Summary
    An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
    References
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/27/1Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/27/2Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/28/3Mailing List, Third Party Advisory
    openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/28/4Mailing List, Third Party Advisory
    openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfThird Party Advisory
    openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdfPatch, Third Party Advisory
    openssl-security@openssl.orghttps://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148
    openssl-security@openssl.orghttps://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845Third Party Advisory
    openssl-security@openssl.orghttps://kc.mcafee.com/corporate/index?page=content&id=SB10356Third Party Advisory
    openssl-security@openssl.orghttps://lists.debian.org/debian-lts-announce/2021/08/msg00029.htmlMailing List, Third Party Advisory
    openssl-security@openssl.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/
    openssl-security@openssl.orghttps://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013Third Party Advisory
    openssl-security@openssl.orghttps://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.ascThird Party Advisory
    openssl-security@openssl.orghttps://security.gentoo.org/glsa/202103-03Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20210326-0006/Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20210513-0002/Third Party Advisory
    openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20240621-0006/
    openssl-security@openssl.orghttps://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdThird Party Advisory
    openssl-security@openssl.orghttps://www.debian.org/security/2021/dsa-4875Third Party Advisory
    openssl-security@openssl.orghttps://www.openssl.org/news/secadv/20210325.txtVendor Advisory
    openssl-security@openssl.orghttps://www.oracle.com//security-alerts/cpujul2021.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuapr2022.htmlPatch, Third Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
    openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuoct2021.htmlThird Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-05Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-06Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-09Third Party Advisory
    openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-10Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/27/1Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/27/2Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/28/3Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/28/4Mailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdfPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148
    af854a3a-2127-422b-91ae-364da2661108https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://kc.mcafee.com/corporate/index?page=content&id=SB10356Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2021/08/msg00029.htmlMailing List, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/
    af854a3a-2127-422b-91ae-364da2661108https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.ascThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.gentoo.org/glsa/202103-03Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20210326-0006/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20210513-0002/Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20240621-0006/
    af854a3a-2127-422b-91ae-364da2661108https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.debian.org/security/2021/dsa-4875Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.openssl.org/news/secadv/20210325.txtVendor Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com//security-alerts/cpujul2021.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuapr2022.htmlPatch, Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuoct2021.htmlThird Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-05Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-06Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-09Third Party Advisory
    af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-10Third Party Advisory
    Impacted products
    Vendor Product Version
    openssl openssl *
    debian debian_linux 9.0
    debian debian_linux 10.0
    freebsd freebsd 12.2
    freebsd freebsd 12.2
    freebsd freebsd 12.2
    netapp active_iq_unified_manager -
    netapp cloud_volumes_ontap_mediator -
    netapp e-series_performance_analyzer -
    netapp oncommand_insight -
    netapp oncommand_workflow_automation -
    netapp ontap_select_deploy_administration_utility -
    netapp santricity_smi-s_provider -
    netapp snapcenter -
    netapp storagegrid -
    tenable log_correlation_engine *
    tenable nessus *
    tenable nessus_network_monitor 5.11.0
    tenable nessus_network_monitor 5.11.1
    tenable nessus_network_monitor 5.12.0
    tenable nessus_network_monitor 5.12.1
    tenable nessus_network_monitor 5.13.0
    tenable tenable.sc *
    fedoraproject fedora 34
    mcafee web_gateway 8.2.19
    mcafee web_gateway 9.2.10
    mcafee web_gateway 10.1.1
    mcafee web_gateway_cloud_service 8.2.19
    mcafee web_gateway_cloud_service 9.2.10
    mcafee web_gateway_cloud_service 10.1.1
    checkpoint quantum_security_management_firmware r80.40
    checkpoint quantum_security_management_firmware r81
    checkpoint quantum_security_management -
    checkpoint multi-domain_management_firmware r80.40
    checkpoint multi-domain_management_firmware r81
    checkpoint multi-domain_management -
    checkpoint quantum_security_gateway_firmware r80.40
    checkpoint quantum_security_gateway_firmware r81
    checkpoint quantum_security_gateway -
    oracle communications_communications_policy_management 12.6.0.0.0
    oracle enterprise_manager_for_storage_management 13.4.0.0
    oracle essbase 21.2
    oracle graalvm 19.3.5
    oracle graalvm 20.3.1.2
    oracle graalvm 21.0.0.2
    oracle jd_edwards_enterpriseone_tools *
    oracle jd_edwards_world_security a9.4
    oracle mysql_connectors *
    oracle mysql_server *
    oracle mysql_server *
    oracle mysql_workbench *
    oracle peoplesoft_enterprise_peopletools 8.57
    oracle peoplesoft_enterprise_peopletools 8.58
    oracle peoplesoft_enterprise_peopletools 8.59
    oracle primavera_unifier *
    oracle primavera_unifier 19.12
    oracle primavera_unifier 20.12
    oracle primavera_unifier 21.12
    oracle secure_backup *
    oracle secure_global_desktop 5.6
    oracle zfs_storage_appliance_kit 8.8
    sonicwall sma100_firmware *
    sonicwall sma100 -
    sonicwall capture_client 3.5
    sonicwall sonicos 7.0.1.0
    siemens ruggedcom_rcm1224_firmware *
    siemens ruggedcom_rcm1224 -
    siemens scalance_lpe9403_firmware *
    siemens scalance_lpe9403 -
    siemens scalance_m-800_firmware *
    siemens scalance_m-800 -
    siemens scalance_s602_firmware *
    siemens scalance_s602 -
    siemens scalance_s612_firmware *
    siemens scalance_s612 -
    siemens scalance_s615_firmware *
    siemens scalance_s615 -
    siemens scalance_s623_firmware *
    siemens scalance_s623 -
    siemens scalance_s627-2m_firmware *
    siemens scalance_s627-2m -
    siemens scalance_sc-600_firmware *
    siemens scalance_sc-600 -
    siemens scalance_w700_firmware *
    siemens scalance_w700 -
    siemens scalance_w1700_firmware *
    siemens scalance_w1700 -
    siemens scalance_xb-200_firmware *
    siemens scalance_xb-200 -
    siemens scalance_xc-200_firmware *
    siemens scalance_xc-200 -
    siemens scalance_xf-200ba_firmware *
    siemens scalance_xf-200ba -
    siemens scalance_xm-400_firmware *
    siemens scalance_xm-400 -
    siemens scalance_xp-200_firmware *
    siemens scalance_xp-200 -
    siemens scalance_xr-300wg_firmware *
    siemens scalance_xr-300wg -
    siemens scalance_xr524-8c_firmware *
    siemens scalance_xr524-8c -
    siemens scalance_xr526-8c_firmware *
    siemens scalance_xr526-8c -
    siemens scalance_xr528-6m_firmware *
    siemens scalance_xr528-6m -
    siemens scalance_xr552-12_firmware *
    siemens scalance_xr552-12 -
    siemens simatic_cloud_connect_7_firmware *
    siemens simatic_cloud_connect_7_firmware -
    siemens simatic_cloud_connect_7 -
    siemens simatic_cp_1242-7_gprs_v2_firmware *
    siemens simatic_cp_1242-7_gprs_v2_firmware -
    siemens simatic_cp_1242-7_gprs_v2 -
    siemens simatic_hmi_basic_panels_2nd_generation_firmware *
    siemens simatic_hmi_basic_panels_2nd_generation -
    siemens simatic_hmi_comfort_outdoor_panels_firmware *
    siemens simatic_hmi_comfort_outdoor_panels -
    siemens simatic_hmi_ktp_mobile_panels_firmware *
    siemens simatic_hmi_ktp_mobile_panels -
    siemens simatic_mv500_firmware *
    siemens simatic_mv500 -
    siemens simatic_net_cp_1243-1_firmware *
    siemens simatic_net_cp_1243-1 -
    siemens simatic_net_cp1243-7_lte_eu_firmware *
    siemens simatic_net_cp1243-7_lte_eu -
    siemens simatic_net_cp1243-7_lte_us_firmware *
    siemens simatic_net_cp1243-7_lte_us -
    siemens simatic_net_cp_1243-8_irc_firmware *
    siemens simatic_net_cp_1243-8_irc -
    siemens simatic_net_cp_1542sp-1_irc_firmware *
    siemens simatic_net_cp_1542sp-1_irc -
    siemens simatic_net_cp_1543-1_firmware *
    siemens simatic_net_cp_1543-1 -
    siemens simatic_net_cp_1543sp-1_firmware *
    siemens simatic_net_cp_1543sp-1 -
    siemens simatic_net_cp_1545-1_firmware *
    siemens simatic_net_cp_1545-1 -
    siemens simatic_pcs_7_telecontrol_firmware *
    siemens simatic_pcs_7_telecontrol -
    siemens simatic_pcs_neo_firmware *
    siemens simatic_pcs_neo -
    siemens simatic_pdm_firmware *
    siemens simatic_pdm -
    siemens simatic_process_historian_opc_ua_server_firmware *
    siemens simatic_process_historian_opc_ua_server -
    siemens simatic_rf166c_firmware *
    siemens simatic_rf166c -
    siemens simatic_rf185c_firmware *
    siemens simatic_rf185c -
    siemens simatic_rf186c_firmware *
    siemens simatic_rf186c -
    siemens simatic_rf186ci_firmware *
    siemens simatic_rf186ci -
    siemens simatic_rf188c_firmware *
    siemens simatic_rf188c -
    siemens simatic_rf188ci_firmware *
    siemens simatic_rf188ci -
    siemens simatic_rf360r_firmware *
    siemens simatic_rf360r -
    siemens simatic_s7-1200_cpu_1211c_firmware *
    siemens simatic_s7-1200_cpu_1211c -
    siemens simatic_s7-1200_cpu_1212c_firmware *
    siemens simatic_s7-1200_cpu_1212c -
    siemens simatic_s7-1200_cpu_1212fc_firmware *
    siemens simatic_s7-1200_cpu_1212fc -
    siemens simatic_s7-1200_cpu_1214_fc_firmware *
    siemens simatic_s7-1200_cpu_1214_fc -
    siemens simatic_s7-1200_cpu_1214c_firmware *
    siemens simatic_s7-1200_cpu_1214c -
    siemens simatic_s7-1200_cpu_1214_fc_firmware *
    siemens simatic_s7-1200_cpu_1214_fc -
    siemens simatic_s7-1200_cpu_1215_fc_firmware *
    siemens simatic_s7-1200_cpu_1215_fc -
    siemens simatic_s7-1200_cpu_1215c_firmware *
    siemens simatic_s7-1200_cpu_1215c -
    siemens simatic_s7-1200_cpu_1217c_firmware *
    siemens simatic_s7-1200_cpu_1217c -
    siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware *
    siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp -
    siemens sinamics_connect_300_firmware *
    siemens sinamics_connect_300 -
    siemens tim_1531_irc_firmware *
    siemens tim_1531_irc -
    siemens simatic_logon *
    siemens simatic_logon 1.5
    siemens simatic_wincc_runtime_advanced *
    siemens simatic_wincc_telecontrol -
    siemens sinec_nms 1.0
    siemens sinec_nms 1.0
    siemens sinec_pni -
    siemens sinema_server 14.0
    siemens sinema_server 14.0
    siemens sinema_server 14.0
    siemens sinema_server 14.0
    siemens sinema_server 14.0
    siemens sinumerik_opc_ua_server *
    siemens tia_administrator *
    siemens sinec_infrastructure_network_services *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *
    nodejs node.js *

    {
      "affected": [
        {
          "affectedData": [
            {
              "product": "OpenSSL",
              "vendor": "OpenSSL",
              "versions": [
                {
                  "status": "affected",
                  "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)"
                }
              ]
            }
          ],
          "source": "openssl-security@openssl.org"
        }
      ],
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B213E696-A6D9-45E7-B4E4-E4CFE54ECEB8",
                  "versionEndExcluding": "1.1.1k",
                  "versionStartIncluding": "1.1.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:-:*:*:*:*:*:*",
                  "matchCriteriaId": "73D9C08B-8F5B-40C4-A5BD-B00D2E4C012D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p1:*:*:*:*:*:*",
                  "matchCriteriaId": "62A178A3-6A52-4981-9A27-FB07AD8AF778",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p2:*:*:*:*:*:*",
                  "matchCriteriaId": "54A487B1-E5CE-4C76-87E8-518D24C5D86D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*",
                  "matchCriteriaId": "3A756737-1CC4-42C2-A4DF-E1C893B4E2D5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:e-series_performance_analyzer:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "24B8DB06-590A-4008-B0AB-FCD1401C77C6",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:oncommand_insight:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F1BE6C1F-2565-4E97-92AA-16563E5660A5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:oncommand_workflow_automation:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5735E553-9731-4AAC-BCFF-989377F817B3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7CF3019-975D-40BB-A8A4-894E62BD3797",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "361B791A-D336-4431-8F68-8135BEFFAEA2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:snapcenter:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BDFB1169-41A0-4A86-8E4F-FDA9730B1E94",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:netapp:storagegrid:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8ADFF451-740F-4DBA-BD23-3881945D3E40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:tenable:log_correlation_engine:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4ACF85D6-6B45-43DA-9C01-F0208186F014",
                  "versionEndExcluding": "6.0.9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0AC12300-9051-4C70-9941-9FE5E64B4B30",
                  "versionEndIncluding": "8.13.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "657682A0-54D5-4DC6-A98E-8BAF685926C4",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8FC5C76C-3474-4B26-8CF0-2DFAFA3D5458",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8661D361-71B5-4C41-A818-C89EC551D900",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "253603DC-2D92-442A-B3A8-A63E14D8A070",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.13.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E112CFF-31F9-4D87-9A1B-AE0FCF69615E",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:tenable:tenable.sc:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AC1721B5-9FCD-47C3-8338-E02932CF2C05",
                  "versionEndIncluding": "5.17.0",
                  "versionStartIncluding": "5.13.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A930E247-0B43-43CB-98FF-6CE7B8189835",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway:8.2.19:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DEA7F1FD-9FAB-4654-98B0-4588EEC8B69A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway:9.2.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "868B2C4B-CE6B-41DA-A373-7D4FA51EFE9F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway:10.1.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "550F47A2-3393-481E-BC40-CE606BFA8776",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:8.2.19:*:*:*:*:*:*:*",
                  "matchCriteriaId": "43392D27-6C07-41C7-A17F-10C433338CE9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:9.2.10:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8FBF6C4C-195F-49A7-861D-52677D9BE58D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:10.1.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90732D53-E802-4E1B-B6C8-B1FDCE7905A4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r80.40:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A98B128A-C58E-48EC-B691-AF73126A0822",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r81:*:*:*:*:*:*:*",
                  "matchCriteriaId": "345B990F-C1C4-440B-804E-0A2882FE7C01",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:checkpoint:quantum_security_management:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "08601413-25E2-4977-B67A-C11A9D788EA8",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r80.40:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EFC067CC-EB90-43F5-9674-089D5C611573",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r81:*:*:*:*:*:*:*",
                  "matchCriteriaId": "80B223A7-1039-445D-ABE1-5E481004D956",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:checkpoint:multi-domain_management:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1584E1B4-412C-40E2-BF07-4E464692F2AE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r80.40:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A0002A29-8B42-445D-9EC4-58BC93194241",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r81:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3B0EDB21-9305-4601-AB96-A77BD00F311D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:checkpoint:quantum_security_gateway:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9016DDF6-285C-4E64-88D0-29ECCEF048F8",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:oracle:communications_communications_policy_management:12.6.0.0.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "570DB369-A31B-4108-A7FD-09F674129603",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:enterprise_manager_for_storage_management:13.4.0.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61516569-C48F-4362-B334-8CA10EDB0EC2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:essbase:21.2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "394A16F2-CCD4-44E5-BF6B-E0C782A9FA38",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:19.3.5:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "058C7C4B-D692-49DE-924A-C2725A8162D3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:20.3.1.2:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "0F0434A5-F2A1-4973-917C-A95F2ABE97D1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:graalvm:21.0.0.2:*:*:*:enterprise:*:*:*",
                  "matchCriteriaId": "96DD93E0-274E-4C36-99F3-EEF085E57655",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:jd_edwards_enterpriseone_tools:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86305E47-33E9-411C-B932-08C395C09982",
                  "versionEndExcluding": "9.2.6.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:jd_edwards_world_security:a9.4:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0B1CAD50-749F-4ADB-A046-BF3585677A58",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_connectors:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A8782A14-89B0-45EE-A5CB-FF715F5BA379",
                  "versionEndIncluding": "8.0.23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C40ECC8-933B-47A4-8082-FCF0EF9C973E",
                  "versionEndIncluding": "5.7.33",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "32714AD7-BCD1-4624-9923-5E6D927CF3CB",
                  "versionEndIncluding": "8.0.23",
                  "versionStartIncluding": "8.0.15",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:mysql_workbench:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CB1A94E1-A6C6-488D-A74C-6C0B24637272",
                  "versionEndIncluding": "8.0.23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.57:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7E1E416B-920B-49A0-9523-382898C2979D",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.58:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D9DB4A14-2EF5-4B54-95D2-75E6CF9AA0A9",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.59:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C8AF00C6-B97F-414D-A8DF-057E6BFD8597",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:primavera_unifier:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "08FA59A8-6A62-4B33-8952-D6E658F8DAC9",
                  "versionEndIncluding": "17.12",
                  "versionStartIncluding": "17.7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:primavera_unifier:19.12:*:*:*:*:*:*:*",
                  "matchCriteriaId": "10864586-270E-4ACF-BDCC-ECFCD299305F",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:primavera_unifier:20.12:*:*:*:*:*:*:*",
                  "matchCriteriaId": "38340E3C-C452-4370-86D4-355B6B4E0A06",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:primavera_unifier:21.12:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E9C55C69-E22E-4B80-9371-5CD821D79FE2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:secure_backup:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C01E8B82-71C7-4A4A-A70A-7B147524AB4A",
                  "versionEndExcluding": "18.1.0.1.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:secure_global_desktop:5.6:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9DA11710-9EA8-49B4-8FD1-3AEE442F6ADC",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:oracle:zfs_storage_appliance_kit:8.8:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D3E503FB-6279-4D4A-91D8-E237ECF9D2B0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:sonicwall:sma100_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6E8B6D50-D482-43E9-A20D-FA77FD59AE2D",
                  "versionEndExcluding": "10.2.1.0-17sv",
                  "versionStartIncluding": "10.2.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:sonicwall:sma100:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E4A2B7B-40F5-4AE0-ACC7-E94B82435DBA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:sonicwall:capture_client:3.5:*:*:*:*:*:*:*",
                  "matchCriteriaId": "349EB4AE-65E3-42DC-8F9C-3A1A155324D7",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:sonicwall:sonicos:7.0.1.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2BD8688A-2D55-4A7E-A143-1BD0FCF957B0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:ruggedcom_rcm1224_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5081E52B-E7C0-46BD-B1D0-2C70ABCC8831",
                  "versionStartIncluding": "6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:ruggedcom_rcm1224:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3747CDD7-E833-4B68-A362-77D6A2E9D888",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_lpe9403_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "058D21EA-E94C-4DDC-AD92-967DAC934457",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_lpe9403:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "52A77C9D-E59C-4397-B834-797D7B334A6B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "424CD8EA-D8CB-40C7-8E0F-AC4B05C59C99",
                  "versionStartIncluding": "6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "858B6A84-5D0E-4E23-AE32-A45B51BAC8CF",
                  "versionStartIncluding": "4.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F4D89D82-C2CE-44DC-A05B-B956F20BF4E3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D173626B-9C50-489F-8BA4-1C45E5F96526",
                  "versionStartIncluding": "4.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CA7B48D2-0D17-420D-AAE1-35E5C0BE2924",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E967F5FC-6F3E-4982-8813-CA1DAF3BE165",
                  "versionStartIncluding": "6.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "81F315D8-0B26-4442-B330-85124017A482",
                  "versionStartIncluding": "4.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F80D9A79-7984-462B-B4B9-6A4429422038",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6F20F735-7A70-4A24-9621-786F99C8F87D",
                  "versionStartIncluding": "4.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B51B40F8-71D2-4D2D-8EC2-CE154A6D7533",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "973B8030-B630-4D67-B897-25A359A96185",
                  "versionStartIncluding": "2.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "725C671B-D7A0-48CF-8A31-5F9C4173F1DD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "86EA8E3F-81BD-47BC-9834-A9B69CA7E70C",
                  "versionStartIncluding": "6.5",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "BE116AD9-B55F-41C8-8B55-329809DB63E1",
                  "versionStartIncluding": "2.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5D9A73DD-4A21-4096-B4B6-A0A825E71006",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "144CDF5E-7E07-428B-B4DF-C94992B3A44A",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "339FFBDF-6957-481F-84CE-878B5CAAD9C8",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6FBB13D3-4E04-4D01-B880-C16C4FFA240B",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E40058B3-3726-4F6A-AB41-7679487639F2",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xm-400:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "798E900F-5EF9-4B39-B8C2-79FAE659E7F5",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1E642D10-E701-44DF-863B-D0DAA5530F50",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4A53C2B5-A3FD-44CC-A78B-D2124EF37DB4",
                  "versionEndExcluding": "4.3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "54FBE4D4-F31E-4B61-9216-44C8EC2988AB",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "20511D61-FC1D-453E-BDF6-D3FB9951192A",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "640AC619-B516-46FC-821B-09C4542A3FD6",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1FB979DB-731B-4693-A9F8-B11ED953717C",
                  "versionEndExcluding": "6.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "09743616-31C9-4E47-8A4A-B15D76204BE7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "886D2FE6-B054-4E3B-BACB-F08C0A119A80",
                  "versionStartIncluding": "1.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3B185B70-CAC9-47AC-8639-7A4707C21540",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_cloud_connect_7:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9FA78457-260C-467B-9785-04B3C8EDF3B3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ABEA3BEE-E7AF-4C9A-ADE4-CE7FC1DB7639",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "049460B8-6186-44F9-B41F-284A2EC0B3B4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "205482DA-548C-4757-91F0-1599438873BD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_basic_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "45208694-635A-42AC-B668-8B67C60568B8",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_basic_panels_2nd_generation:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7D8F8BCE-35CE-492A-8BFE-2C36EA51CE5C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B4C147D9-4649-4289-B18B-55BD6E33521A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "54EFA8B5-8DA1-4547-9E15-BDC265C56006",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DE4FA1E6-4C5A-4CDC-AD40-E384C0BCA90D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "93A5B50E-0316-4189-8F41-54732CFCF63F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D254DA1D-C53E-426B-9C69-580CC47CF0AA",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "65278BA0-3C81-4D81-9801-D7BE3A1D7680",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C06A02ED-0BA3-4A2C-AF0C-689B8AEB34B8",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_eu:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "209C7B1E-10F6-4215-AF69-CC36192E0FCE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CF8C00EE-1154-440C-A223-A2CE99CE3126",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_us:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "171A9543-E677-422F-8AEA-1BC2D0E53593",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DB201DD3-8890-453E-A11E-1E13B3DAB3F9",
                  "versionStartIncluding": "3.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-8_irc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "350FD323-C876-4C7A-A2E7-4B0660C87F6C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "61E498B1-87FF-454B-8DF0-61D0D3208491",
                  "versionStartIncluding": "2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C1EE2F10-A7A6-486F-AE5C-53AE25BAF200",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "90FB801F-11B5-438C-98A1-E928BFEA2ADB",
                  "versionEndExcluding": "3.0",
                  "versionStartIncluding": "2.2",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543-1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F56C2BDC-928E-491A-8E7C-F976B3787C7A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E4BA1E6-64F7-4B96-8302-134057DAB1BE",
                  "versionStartIncluding": "2.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543sp-1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "783B50B8-2FB7-4982-88AA-B4F2AD094796",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1545-1_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1DCA9544-DD17-4F56-B34C-91A3F37154AF",
                  "versionStartIncluding": "1.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1545-1:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1256EB4B-DD8A-4F99-AE69-F74E8F789C63",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_pcs_7_telecontrol_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5C25165E-EDE9-42F1-A3B9-0E47630D49CC",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_pcs_7_telecontrol:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5BF281FB-26E0-43E4-A2B6-4015661368AC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_pcs_neo_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6EEACFC9-41B7-4EE0-9427-692363880326",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_pcs_neo:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EF3CA343-CA2A-4593-930C-158612CE7A55",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_pdm_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7E9AE23E-7DAE-4191-BA4E-A7CD655C4BC8",
                  "versionStartIncluding": "9.1.0.7",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_pdm:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E092B735-42D5-48D5-947B-288C0FA2E180",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D874D636-392A-4750-B976-F411DBCEBA8D",
                  "versionStartIncluding": "2019",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "14EC9343-7778-40B0-A74D-5C156FF2A229",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "968FBB4E-5B0B-43D4-B3AD-418028093990",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "391AD485-A49D-43D0-AAE5-1F58B38D4E22",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "5212F097-B65A-4D73-BB6F-49687F8AD980",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D806113B-57EB-4AA0-9D5E-12E30337A93B",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "53FA50A7-2DF6-454E-8A8E-838C392AB417",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1EAEB335-BD22-4CEF-A3EA-9D98A09FEBF0",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7F3D41E9-58B3-4251-8710-A8C4A24ABBD3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FC628CB7-0816-4267-9C5D-954BD0233D2E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0927991-E820-4FC3-9EFE-96E4C9BFCCCD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "88E64167-16AA-48D7-BCDC-B15D37FA666D",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "63F05227-208B-42C8-8D56-A5D106CAD32F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "47F1294A-1C26-4D43-9C53-D833F2510536",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4AF60081-D534-44F5-972F-23257F16F372",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AEF1726E-B56F-4D39-AFF4-E79A3CA00DE6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4948734A-0AAD-4D28-B7FF-FFBBB9AA39C6",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6EE37798-B068-40E5-BC03-1D8D303E5926",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8E0C491C-5C4A-4F1C-ABD4-9502A54AAA78",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "E7657063-1296-4734-B108-A2FF7A01B07F",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8C477CCD-06C7-4907-8B0C-4FCE7F6DADAD",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:sinamics_connect_300_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3360ACCE-E735-4E34-B278-0D4460E74CBF",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:sinamics_connect_300:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7B854F5B-78C7-41FE-9364-5E71B36342A3",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D2B20D95-C4B3-4D13-A3D8-F22AC42DC059",
                  "versionEndExcluding": "2.2",
                  "versionStartIncluding": "2.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_logon:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D6F24E40-F3F0-48F3-B3DC-5F98B0564F7A",
                  "versionStartIncluding": "1.6.0.2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_logon:1.5:sp3_update_1:*:*:*:*:*:*",
                  "matchCriteriaId": "423359E5-9C36-4C6B-AB24-B030E6C61D53",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:simatic_wincc_telecontrol:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F3169FD3-CBA2-417C-95EF-4F8AE9FAB5AD",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*",
                  "matchCriteriaId": "4ED13FC8-63C0-42C6-A51C-C480C45327C2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "E68FE047-8F53-46B8-82D4-9342B1C8CA55",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinec_pni:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "1353DC31-FB12-427A-B1B2-9164A4BEE14B",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:-:*:*:*:*:*:*",
                  "matchCriteriaId": "B0A5CC25-A323-4D49-8989-5A417D12D646",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp1:*:*:*:*:*:*",
                  "matchCriteriaId": "A690BCD3-6497-43F7-8A51-E033B9121DC8",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2:*:*:*:*:*:*",
                  "matchCriteriaId": "AA375D44-ECC5-4BD3-A3D5-6D2AA68782D5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update1:*:*:*:*:*:*",
                  "matchCriteriaId": "6CD26C73-B61F-424B-91C2-352E2CAE6666",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update2:*:*:*:*:*:*",
                  "matchCriteriaId": "DB4EA15F-ECA4-477F-948F-490FC90BC66A",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ABA14E65-214C-431D-A49A-D8FC142D4541",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "915B09CB-CA0A-445B-89D3-16AE9B08858E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B0F46497-4AB0-49A7-9453-CC26837BF253",
                  "versionEndExcluding": "1.0.1.1",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "25A3180B-21AF-4010-9DAB-41ADFD2D8031",
                  "versionEndIncluding": "10.12.0",
                  "versionStartIncluding": "10.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "43B199B4-D89C-483D-ACAE-6CB2A59EE67C",
                  "versionEndIncluding": "10.24.0",
                  "versionStartIncluding": "10.13.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "564ED5C8-50D7-413A-B88E-E62B6C07336A",
                  "versionEndIncluding": "12.12.0",
                  "versionStartIncluding": "12.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "3DEBF7C8-B000-47B9-B597-DC440F2603B3",
                  "versionEndExcluding": "12.22.1",
                  "versionStartIncluding": "12.13.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "428DCD7B-6F66-4F18-B780-5BD80143D482",
                  "versionEndIncluding": "14.14.0",
                  "versionStartIncluding": "14.0.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
                  "matchCriteriaId": "380D03F3-6A7E-43A2-B002-FB2521FD3C58",
                  "versionEndExcluding": "14.16.1",
                  "versionStartIncluding": "14.15.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
                  "matchCriteriaId": "3ED4D313-F372-4CC1-BE11-6BBA2F0E90E3",
                  "versionEndExcluding": "15.14.0",
                  "versionStartIncluding": "15.0.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "cveTags": [],
      "descriptions": [
        {
          "lang": "en",
          "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
        },
        {
          "lang": "es",
          "value": "Un servidor OpenSSL TLS puede cometer un fallo si un cliente env\u00eda un mensaje ClientHello de renegociaci\u00f3n dise\u00f1ado maliciosamente.\u0026#xa0;Si una renegociaci\u00f3n de TLSv1.2 ClientHello omite la extensi\u00f3n signature_algorithms (donde estaba presente en el ClientHello inicial), pero incluye una extensi\u00f3n signature_algorithms_cert, se producir\u00e1 una desreferencia del puntero NULL, lo que conllevar\u00e1 un bloqueo y un ataque de denegaci\u00f3n de servicio.\u0026#xa0;Un servidor solo es vulnerable si tiene TLSv1.2 y la renegociaci\u00f3n habilitada (que es la configuraci\u00f3n predeterminada).\u0026#xa0;Los clientes de OpenSSL TLS no est\u00e1n afectados por este problema.\u0026#xa0;Todas las versiones de OpenSSL versi\u00f3n 1.1.1 est\u00e1n afectadas por este problema.\u0026#xa0;Los usuarios de estas versiones deben actualizar a OpenSSL versi\u00f3n 1.1.1k.\u0026#xa0;OpenSSL versi\u00f3n 1.0.2 no est\u00e1 afectado por este problema.\u0026#xa0;Corregido en OpenSSL versi\u00f3n 1.1.1k (Afectadas versiones 1.1.1-1.1.1j)"
        }
      ],
      "id": "CVE-2021-3449",
      "lastModified": "2026-10-08T22:17:11.243",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "MEDIUM",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 4.3,
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 8.6,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "HIGH",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 5.9,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.2,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ],
        "ssvcV203": [
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "ssvcData": {
              "id": "CVE-2021-3449",
              "options": [
                {
                  "exploitation": "none"
                },
                {
                  "automatable": "yes"
                },
                {
                  "technicalImpact": "partial"
                }
              ],
              "role": "CISA Coordinator",
              "timestamp": "2026-10-08T21:05:43.522199Z",
              "version": "2.0.3"
            }
          }
        ]
      },
      "published": "2021-03-25T15:15:13.450",
      "references": [
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202103-03"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
        },
        {
          "source": "openssl-security@openssl.org",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2021/dsa-4875"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.openssl.org/news/secadv/20210325.txt"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-05"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-06"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-09"
        },
        {
          "source": "openssl-security@openssl.org",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-10"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Third Party Advisory"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202103-03"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.debian.org/security/2021/dsa-4875"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://www.openssl.org/news/secadv/20210325.txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Patch",
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-05"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-06"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-09"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Third Party Advisory"
          ],
          "url": "https://www.tenable.com/security/tns-2021-10"
        }
      ],
      "sourceIdentifier": "openssl-security@openssl.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-476"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    }

    CVE-2026-111497 (GCVE-0-2026-111497)

    Vulnerability from nvd – Published: 2026-10-22 13:35 – Updated: 2026-11-18 18:32
    VLAI CISA Previdian
    Title
    Out-of-Bounds Write in Google Brotli Decoder
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-23 00:00 UTC
    CWE
    Assigner
    Google CNA under the Google root
    CNA scorecard B 78/100 over 38 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Google Brotli Affected: 1.0.3 , < 1.0.10 (semver)
    Affected: 1.1.0 , < 1.1.1 (semver)
    Affected: 1.2.0 , < 1.2.1 (semver)
    Create a notification for this product.
    Siemens blueplanet 100 NX3 M8 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 125 NX3 M10 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 87.0 TL3 – 165 TL3 (GEN1 / GEN2) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet gridsave 100 – 165 TL3 (HV) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet gridsave 92 – 137 TL3 (GEN1 / GEN2) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Gridscale X DSA Affected: V5.3 , < V5.4 (custom)
    Create a notification for this product.
    Siemens Gridscale X PSS®E Affected: 0 , < V36.8.0 (custom)
    Create a notification for this product.
    Siemens Heliox Dual Port 60kW Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Integrated PA Suite Tester Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SENTRON Powermanager V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SENTRON Powermanager V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICAM PAS CC Affected: V6.02 , < * (custom)
    Create a notification for this product.
    Siemens SICAM SCC Affected: V7.01 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE FLEX Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE UC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Go Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Setup Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCharge AC Series Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCloud Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Cloud Connector Configurator Affected: 0 , < V1.24.3 (custom)
    Create a notification for this product.
    Siemens Common Configurator (CC on IEM) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Common Configurator on Device (CC on Edge) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Data Flow Monitoring Affected: 0 , < V3.0.18 (custom)
    Create a notification for this product.
    Siemens Databus Configurator Affected: 0 , < V4.0.1 (custom)
    Create a notification for this product.
    Siemens DataXess Configurator Affected: 0 , < V1.5.7 (custom)
    Create a notification for this product.
    Siemens Edge OPC UA Server Configurator Affected: 0 , < V2.3.10 (custom)
    Create a notification for this product.
    Siemens Flow Creator Configurator Affected: 0 , < V1.15.1 (custom)
    Create a notification for this product.
    Siemens Industrial Edge Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Industrial Edge Management Cloud Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Innexis Architecture Native Acceleration 2026 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Process Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Intelligence Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Intra Plant Logistics Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Quality Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter RDnL Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter X Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Pro Essentials Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Pro Student Edition Affected: 0 , < * (custom)
    Create a notification for this product.

    50 of 76 products shown. All of them on the page of CVE-2026-111497.

    Date Public
    2026-02-27 07:50
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-111497",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-23T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:48.896Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-11-03T21:05:46.791Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
              },
              {
                "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
              },
              {
                "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
              },
              {
                "url": "https://broccoli2shell.com"
              },
              {
                "url": "https://github.com/dotnet/announcements/issues/494"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
              },
              {
                "url": "https://patchtheplanet.org/brotli"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 100 NX3 M8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 100 NX3 M8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 125 NX3 M10",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet gridsave 100 \u2013 165 TL3 (HV)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X DSA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.4",
                    "status": "affected",
                    "version": "V5.3",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X PSS\u00aeE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V36.8.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Integrated PA Suite Tester",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICAM PAS CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V6.02",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICAM SCC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V7.01",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCharge AC Series",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Cloud Connector Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.24.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator\u00a0(CC on IEM)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator on Device\u00a0(CC on Edge)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Data Flow Monitoring",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.18",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Databus Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DataXess Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.5.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Edge OPC UA Server Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Flow Creator Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Management Cloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Innexis Architecture Native Acceleration 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PAVE360 Automotive 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Process Preparation X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Executable Digital Twin",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Studio",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2412",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2506",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2512",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2606",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "COMOS Walkinside",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Project Server Web Administration Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC BRAUMAT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Profiling Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC SISTAR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Companion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.20",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.20.17.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.21",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.21.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Runtime Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified for Industrial Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified PC Runtime",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified SIQENCE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7/V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Administrator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "User Management Component (UMC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.4.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-18T18:32:29.836Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI Codex Security - Khai Tran and Sylvie Mayer"
            }
          ],
          "datePublic": "2026-02-27T07:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA buffer overflow vulnerability in the Brotli decoder (\u003ccode\u003ec/dec/decode.c\u003c/code\u003e) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\u003cspan\u003e\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-252",
                  "description": "CWE-252 Unchecked Return Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-27T14:58:42.704Z",
            "orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
            "shortName": "Google"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
            },
            {
              "tags": [
                "release-notes",
                "third-party-advisory"
              ],
              "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
                }
              ],
              "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Out-of-Bounds Write in Google Brotli Decoder",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
        "assignerShortName": "Google",
        "cveId": "CVE-2026-111497",
        "datePublished": "2026-10-22T13:35:41.975Z",
        "dateReserved": "2026-10-16T09:58:17.790Z",
        "dateUpdated": "2026-11-18T18:32:29.836Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-111497 (GCVE-0-2026-111497)

    Vulnerability from cvelistv5 – Published: 2026-10-22 13:35 – Updated: 2026-11-18 18:32
    VLAI CISA Previdian
    Title
    Out-of-Bounds Write in Google Brotli Decoder
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-23 00:00 UTC
    CWE
    Assigner
    Google CNA under the Google root
    CNA scorecard B 78/100 over 38 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Google Brotli Affected: 1.0.3 , < 1.0.10 (semver)
    Affected: 1.1.0 , < 1.1.1 (semver)
    Affected: 1.2.0 , < 1.2.1 (semver)
    Create a notification for this product.
    Siemens blueplanet 100 NX3 M8 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 125 NX3 M10 Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet 87.0 TL3 – 165 TL3 (GEN1 / GEN2) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet gridsave 100 – 165 TL3 (HV) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens blueplanet gridsave 92 – 137 TL3 (GEN1 / GEN2) Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Desigo CC family V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Gridscale X DSA Affected: V5.3 , < V5.4 (custom)
    Create a notification for this product.
    Siemens Gridscale X PSS®E Affected: 0 , < V36.8.0 (custom)
    Create a notification for this product.
    Siemens Heliox Dual Port 60kW Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Integrated PA Suite Tester Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SENTRON Powermanager V8 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SENTRON Powermanager V9 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICAM PAS CC Affected: V6.02 , < * (custom)
    Create a notification for this product.
    Siemens SICAM SCC Affected: V7.01 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE FLEX Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE UC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Go Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Setup Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCharge AC Series Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCloud Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Cloud Connector Configurator Affected: 0 , < V1.24.3 (custom)
    Create a notification for this product.
    Siemens Common Configurator (CC on IEM) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Common Configurator on Device (CC on Edge) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Data Flow Monitoring Affected: 0 , < V3.0.18 (custom)
    Create a notification for this product.
    Siemens Databus Configurator Affected: 0 , < V4.0.1 (custom)
    Create a notification for this product.
    Siemens DataXess Configurator Affected: 0 , < V1.5.7 (custom)
    Create a notification for this product.
    Siemens Edge OPC UA Server Configurator Affected: 0 , < V2.3.10 (custom)
    Create a notification for this product.
    Siemens Flow Creator Configurator Affected: 0 , < V1.15.1 (custom)
    Create a notification for this product.
    Siemens Industrial Edge Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Industrial Edge Management Cloud Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens HyperLynx Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Innexis Architecture Native Acceleration 2026 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Insights Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect Electronics Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Connect MOM Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Core Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Discrete Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Foundation Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Pharma Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Execution Process Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Intelligence Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Intra Plant Logistics Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter Quality Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter RDnL Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Opcenter X Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Pro Essentials Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens PADS Pro Student Edition Affected: 0 , < * (custom)
    Create a notification for this product.

    50 of 76 products shown. All of them on the page of CVE-2026-111497.

    Date Public
    2026-02-27 07:50
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-111497",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-23T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:48.896Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-11-03T21:05:46.791Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
              },
              {
                "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
              },
              {
                "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
              },
              {
                "url": "https://broccoli2shell.com"
              },
              {
                "url": "https://github.com/dotnet/announcements/issues/494"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
              },
              {
                "url": "https://patchtheplanet.org/brotli"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/11/03/2"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 100 NX3 M8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 100 NX3 M8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 125 NX3 M10",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet gridsave 100 \u2013 165 TL3 (HV)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Desigo CC family V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X DSA",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V5.4",
                    "status": "affected",
                    "version": "V5.3",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Gridscale X PSS\u00aeE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V36.8.0",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Integrated PA Suite Tester",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SENTRON Powermanager V9",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICAM PAS CC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V6.02",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICAM SCC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "V7.01",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCharge AC Series",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Cloud Connector Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.24.3",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator\u00a0(CC on IEM)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator on Device\u00a0(CC on Edge)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Data Flow Monitoring",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.0.18",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Databus Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V4.0.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "DataXess Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.5.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Edge OPC UA Server Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.3.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Flow Creator Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.15.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Management Cloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "HyperLynx",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Innexis Architecture Native Acceleration 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Insights Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect Electronics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Connect MOM",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Core",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Discrete",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Foundation",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Pharma",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Execution Process",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intelligence",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Intra Plant Logistics",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter Quality",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter RDnL",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Opcenter X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Essentials",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Pro Student Edition",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PADS Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "PAVE360 Automotive 2026",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Process Preparation X",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Executable Digital Twin",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Simcenter Studio",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2412",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2506",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2512",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Teamcenter V2606",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Designer",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Xpedition Enterprise",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "COMOS Walkinside",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Project Server Web Administration Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC BRAUMAT",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Profiling Tool",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC SISTAR",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V8.2 Update 5",
                    "status": "affected",
                    "version": "V8.2 Update 1",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Companion",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.20",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.20.17.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC OA V3.21",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V3.21.7",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Runtime Professional",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified for Industrial Edge",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified PC Runtime",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC Unified SIQENCE",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC WinCC V7/V8",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "TIA Administrator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "User Management Component (UMC)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V2.15.4.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-11-18T18:32:29.836Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-678870.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-242944.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI Codex Security - Khai Tran and Sylvie Mayer"
            }
          ],
          "datePublic": "2026-02-27T07:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA buffer overflow vulnerability in the Brotli decoder (\u003ccode\u003ec/dec/decode.c\u003c/code\u003e) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\u003cspan\u003e\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-252",
                  "description": "CWE-252 Unchecked Return Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-27T14:58:42.704Z",
            "orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
            "shortName": "Google"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
            },
            {
              "tags": [
                "release-notes",
                "third-party-advisory"
              ],
              "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
                }
              ],
              "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Out-of-Bounds Write in Google Brotli Decoder",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
        "assignerShortName": "Google",
        "cveId": "CVE-2026-111497",
        "datePublished": "2026-10-22T13:35:41.975Z",
        "dateReserved": "2026-10-16T09:58:17.790Z",
        "dateUpdated": "2026-11-18T18:32:29.836Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }