Search
Find a vulnerability
Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
65 vulnerabilities by Contec
FKIE_CVE-2023-29154
Vulnerability from fkie_nvd - Published: 2023-06-01 02:15 - Updated: 2026-10-28 19:10
Severity
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/
Summary
SQL injection vulnerability exists in the CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "versions prior to 3.5.3"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E75EB317-708F-4E02-B521-C788934DFB97",
"versionEndExcluding": "3.5.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "SQL injection vulnerability exists in the CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page."
},
{
"lang": "es",
"value": "Una vulnerabilidad de inyecci\u00f3n SQL existe en las versiones del Sistema HMI CONPROSYS (CHS) anteriores a la 3.5.3. Un usuario que puede acceder al producto afectado con un privilegio administrativo puede ejecutar un comando SQL arbitrario a trav\u00e9s de una entrada especialmente dise\u00f1ada en la p\u00e1gina de configuraci\u00f3n de consultas."
}
],
"id": "CVE-2023-29154",
"lastModified": "2026-10-28T19:10:00.193",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-29154",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T19:24:32.817341Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-06-01T02:15:09.760",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-34081
Vulnerability from fkie_nvd - Published: 2025-07-01 18:15 - Updated: 2026-06-17 09:13
Severity
Summary
The Contec Co.,Ltd. CONPROSYS HMI System (CHS) exposes a PHP phpinfo() debug page to unauthenticated users that may contain sensitive data useful for an attacker.This issue affects CONPROSYS HMI System (CHS): before 3.7.7.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "affected",
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co.,Ltd.",
"versions": [
{
"lessThan": "3.7.7",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "disclosure@vulncheck.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3E21391F-752A-4465-8965-8FE6ADF04C08",
"versionEndExcluding": "3.7.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Contec Co.,Ltd. CONPROSYS HMI System (CHS) exposes a PHP phpinfo() debug page to unauthenticated users that may contain sensitive data useful for an attacker.This issue affects CONPROSYS HMI System (CHS): before 3.7.7."
},
{
"lang": "es",
"value": "Contec Co.,Ltd. CONPROSYS HMI System (CHS) expone una p\u00e1gina de depuraci\u00f3n PHP phpinfo() a usuarios no autenticados que puede contener datos confidenciales \u00fatiles para un atacante. Este problema afecta al sistema HMI CONPROSYS (CHS): antes de la versi\u00f3n 3.7.7."
}
],
"id": "CVE-2025-34081",
"lastModified": "2026-06-17T09:13:26.390",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-34081",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-01T18:48:45.941957Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-07-01T18:15:24.627",
"references": [
{
"source": "disclosure@vulncheck.com",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU92266386/"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.vulncheck.com/advisories/conprosys-hmi-system-exposed-php-debug-info"
}
],
"sourceIdentifier": "disclosure@vulncheck.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-215"
}
],
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2025-34080
Vulnerability from fkie_nvd - Published: 2025-07-01 18:15 - Updated: 2026-06-17 09:13
Severity
Summary
The Contec Co.,Ltd. CONPROSYS HMI System (CHS) is vulnerable to Cross-Site Scripting (XSS) in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.This issue affects CONPROSYS HMI System (CHS): before 3.7.7.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "affected",
"modules": [
"getqsetting.php"
],
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co.,Ltd.",
"versions": [
{
"lessThan": "3.7.7",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"source": "disclosure@vulncheck.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3E21391F-752A-4465-8965-8FE6ADF04C08",
"versionEndExcluding": "3.7.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Contec Co.,Ltd. CONPROSYS HMI System (CHS) is vulnerable to Cross-Site Scripting (XSS) in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.This issue affects CONPROSYS HMI System (CHS): before 3.7.7."
},
{
"lang": "es",
"value": "Contec Co.,Ltd. CONPROSYS HMI System (CHS) es vulnerable a Cross-Site Scripting (XSS) en la funcionalidad getqsetting.php que podr\u00eda permitir la ejecuci\u00f3n reflejada de secuencias de comandos en el navegador durante la interacci\u00f3n. Este problema afecta al sistema HMI CONPROSYS (CHS): anterior a la versi\u00f3n 3.7.7."
}
],
"id": "CVE-2025-34080",
"lastModified": "2026-06-17T09:13:26.273",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2025-34080",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-01T18:47:11.611812Z",
"version": "2.0.3"
}
}
]
},
"published": "2025-07-01T18:15:24.487",
"references": [
{
"source": "disclosure@vulncheck.com",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU92266386/"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.vulncheck.com/advisories/conprosys-hmi-system-reflected-xss"
}
],
"sourceIdentifier": "disclosure@vulncheck.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-2758
Vulnerability from fkie_nvd - Published: 2023-05-31 15:15 - Updated: 2026-06-17 05:53
Severity
3.7 (Low) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
5.3 (Medium) - CVSS:3.1/
Summary
A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://jvn.jp/en/vu/JVNVU93372935/index.html | Third Party Advisory | |
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2023-21 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/en/vu/JVNVU93372935/index.html | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2023-21 | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "CONPROSYS HMI System",
"vendor": "Contec",
"versions": [
{
"lessThanOrEqual": "3.5.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "vulnreport@tenable.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E75EB317-708F-4E02-B521-C788934DFB97",
"versionEndExcluding": "3.5.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A denial of service vulnerability exists in Contec CONPROSYS HMI System versions 3.5.2 and prior. When there is a time-zone mismatch in certain configuration files, a remote, unauthenticated attacker may deny logins for an extended period of time."
}
],
"id": "CVE-2023-2758",
"lastModified": "2026-06-17T05:53:22.033",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 1.4,
"source": "vulnreport@tenable.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-2758",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T20:25:29.496343Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-05-31T15:15:09.473",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/index.html"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2023-21"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/index.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2023-21"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-799"
}
],
"source": "vulnreport@tenable.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-28824
Vulnerability from fkie_nvd - Published: 2023-06-01 02:15 - Updated: 2026-06-17 05:48
Severity
4.9 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
4.9 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
4.9 (Medium) - CVSS:3.1/
Summary
Server-side request forgery vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may bypass the database restriction set on the query setting page, and connect to a user unintended database.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "versions prior to 3.5.3"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E75EB317-708F-4E02-B521-C788934DFB97",
"versionEndExcluding": "3.5.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Server-side request forgery vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may bypass the database restriction set on the query setting page, and connect to a user unintended database."
}
],
"id": "CVE-2023-28824",
"lastModified": "2026-06-17T05:48:50.840",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-28824",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T19:29:12.150296Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-06-01T02:15:09.673",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-918"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-918"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-28713
Vulnerability from fkie_nvd - Published: 2023-06-01 02:15 - Updated: 2026-06-17 05:48
Severity
8.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
8.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
8.1 (High) - CVSS:3.1/
Summary
Plaintext storage of a password exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. Because account information of the database is saved in a local file in plaintext, a user who can access the PC where the affected product is installed can obtain the information. As a result, information in the database may be obtained and/or altered by the user.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "versions prior to 3.5.3"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E75EB317-708F-4E02-B521-C788934DFB97",
"versionEndExcluding": "3.5.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Plaintext storage of a password exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. Because account information of the database is saved in a local file in plaintext, a user who can access the PC where the affected product is installed can obtain the information. As a result, information in the database may be obtained and/or altered by the user."
}
],
"id": "CVE-2023-28713",
"lastModified": "2026-06-17T05:48:37.087",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.2,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-28713",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T19:30:21.235750Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-06-01T02:15:09.637",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-312"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-312"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-28657
Vulnerability from fkie_nvd - Published: 2023-06-01 02:15 - Updated: 2026-06-17 05:48
Severity
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/
Summary
Improper access control vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "versions prior to 3.5.3"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E75EB317-708F-4E02-B521-C788934DFB97",
"versionEndExcluding": "3.5.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper access control vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user of the PC where the affected product is installed may gain an administrative privilege. As a result, information regarding the product may be obtained and/or altered by the user."
}
],
"id": "CVE-2023-28657",
"lastModified": "2026-06-17T05:48:29.233",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-28657",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T19:32:06.363729Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-06-01T02:15:09.597",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-862"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-28651
Vulnerability from fkie_nvd - Published: 2023-06-01 02:15 - Updated: 2026-06-17 05:48
Severity
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/
Summary
Cross-site scripting vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is accessing the affected product with an administrative privilege.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "versions prior to 3.5.3"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E75EB317-708F-4E02-B521-C788934DFB97",
"versionEndExcluding": "3.5.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting vulnerability exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. If a user who can access the affected product with an administrative privilege configures specially crafted settings, an arbitrary script may be executed on the web browser of the other user who is accessing the affected product with an administrative privilege."
}
],
"id": "CVE-2023-28651",
"lastModified": "2026-06-17T05:48:28.367",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-28651",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T20:52:23.669263Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-06-01T02:15:09.550",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-28399
Vulnerability from fkie_nvd - Published: 2023-06-01 02:15 - Updated: 2026-06-17 05:47
Severity
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/
Summary
Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "versions prior to 3.5.3"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E75EB317-708F-4E02-B521-C788934DFB97",
"versionEndExcluding": "3.5.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Incorrect permission assignment for critical resource exists in CONPROSYS HMI System (CHS) versions prior to 3.5.3. ACL (Access Control List) is not appropriately set to the local folder where the affected product is installed, therefore a wide range of privileges is permitted to a user of the PC where the affected product is installed. As a result, the user may be able to destroy the system and/or execute a malicious program."
}
],
"id": "CVE-2023-28399",
"lastModified": "2026-06-17T05:47:38.093",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-28399",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T20:53:17.563643Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-06-01T02:15:09.497",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-22373
Vulnerability from fkie_nvd - Published: 2023-01-20 03:15 - Updated: 2026-06-17 05:35
Severity
5.4 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
5.4 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
5.4 (Medium) - CVSS:3.1/
Summary
Cross-site scripting vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated attacker to inject an arbitrary script and obtain the sensitive information.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "Ver.3.4.5 and earlier"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "925AAC92-DED4-41ED-A11E-91AAB582A8AE",
"versionEndIncluding": "3.4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated attacker to inject an arbitrary script and obtain the sensitive information."
},
{
"lang": "es",
"value": "Vulnerabilidad de cross-site scripting en CONPROSYS HMI System (CHS) Ver.3.4.5 y anteriores permite a un atacante remoto autenticado inyectar un script arbitrario y obtener informaci\u00f3n confidencial."
}
],
"id": "CVE-2023-22373",
"lastModified": "2026-06-17T05:35:15.320",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-22373",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-02T15:29:32.131634Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-01-20T03:15:10.937",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU96873821"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-347-03"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230110_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU96873821"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-347-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230110_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-22339
Vulnerability from fkie_nvd - Published: 2023-01-20 03:15 - Updated: 2026-06-17 05:35
Severity
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
7.5 (High) - CVSS:3.1/
Summary
Improper access control vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticated attacker to bypass access restriction and obtain the server certificate including the private key of the product.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "Ver.3.4.5 and earlier"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "925AAC92-DED4-41ED-A11E-91AAB582A8AE",
"versionEndIncluding": "3.4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper access control vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticated attacker to bypass access restriction and obtain the server certificate including the private key of the product."
},
{
"lang": "es",
"value": "Una vulnerabilidad de control de acceso inadecuado en CONPROSYS HMI System (CHS) Ver.3.4.5 y anteriores permite que un atacante remoto no autenticado evite la restricci\u00f3n de acceso y obtenga el certificado del servidor, incluida la clave privada del producto."
}
],
"id": "CVE-2023-22339",
"lastModified": "2026-06-17T05:35:06.573",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-22339",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-03T20:03:37.484856Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-01-20T03:15:10.770",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU96873821"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-347-03"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230110_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU96873821"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-347-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230110_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-284"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-22334
Vulnerability from fkie_nvd - Published: 2023-01-20 03:15 - Updated: 2026-06-17 05:35
Severity
5.3 (Medium) - CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N
5.3 (Medium) - CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N
5.3 (Medium) - CVSS:3.1/
Summary
Use of password hash instead of password for authentication vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated attacker to obtain user credentials information via a man-in-the-middle attack.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "Ver.3.4.5 and earlier"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "925AAC92-DED4-41ED-A11E-91AAB582A8AE",
"versionEndIncluding": "3.4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Use of password hash instead of password for authentication vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated attacker to obtain user credentials information via a man-in-the-middle attack."
},
{
"lang": "es",
"value": "El uso de hash de contrase\u00f1a en lugar de contrase\u00f1a para la vulnerabilidad de autenticaci\u00f3n en CONPROSYS HMI System (CHS) Ver.3.4.5 y anteriores permite a un atacante autenticado remoto obtener informaci\u00f3n de credenciales de usuario a trav\u00e9s de un ataque de intermediario."
}
],
"id": "CVE-2023-22334",
"lastModified": "2026-06-17T05:35:05.860",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.6,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.6,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-22334",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-03T15:18:39.362291Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-01-20T03:15:10.613",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU96873821"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-347-03"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230110_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU96873821"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-347-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230110_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-22331
Vulnerability from fkie_nvd - Published: 2023-01-20 03:15 - Updated: 2026-06-17 05:35
Severity
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
7.5 (High) - CVSS:3.1/
Summary
Use of default credentials vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticated attacker to alter user credentials information.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "Ver.3.4.5 and earlier"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "925AAC92-DED4-41ED-A11E-91AAB582A8AE",
"versionEndIncluding": "3.4.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Use of default credentials vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticated attacker to alter user credentials information."
},
{
"lang": "es",
"value": "El uso de la vulnerabilidad de credenciales predeterminadas en CONPROSYS HMI System (CHS) Ver.3.4.5 y versiones anteriores permite que un atacante remoto no autenticado altere la informaci\u00f3n de las credenciales del usuario."
}
],
"id": "CVE-2023-22331",
"lastModified": "2026-06-17T05:35:05.340",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-22331",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-03T17:57:41.016834Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-01-20T03:15:09.813",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU96873821"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-347-03"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230110_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU96873821"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-347-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230110_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-269"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-22324
Vulnerability from fkie_nvd - Published: 2023-01-30 07:15 - Updated: 2026-06-17 05:35
Severity
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/
Summary
SQL injection vulnerability in the CONPROSYS HMI System (CHS) Ver.3.5.0 and earlier allows a remote authenticated attacker to execute an arbitrary SQL command. As a result, information stored in the database may be obtained.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "Ver.3.5.0 and earlier"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5CD57955-96C3-4807-8BA1-0DAC528D345C",
"versionEndExcluding": "3.5.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "SQL injection vulnerability in the CONPROSYS HMI System (CHS) Ver.3.5.0 and earlier allows a remote authenticated attacker to execute an arbitrary SQL command. As a result, information stored in the database may be obtained."
},
{
"lang": "es",
"value": "Vulnerabilidad de inyecci\u00f3n SQL en CONPROSYS HMI System (CHS) Ver.3.5.0 y anteriores permite que un atacante remoto autenticado ejecute un comando SQL arbitrario. Como resultado, se puede obtener informaci\u00f3n almacenada en la base de datos."
}
],
"id": "CVE-2023-22324",
"lastModified": "2026-06-17T05:35:02.967",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-22324",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-28T14:07:42.736462Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-01-30T07:15:09.767",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU97195023/"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230124_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU97195023/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230124_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-44456
Vulnerability from fkie_nvd - Published: 2022-12-19 03:15 - Updated: 2026-06-17 05:08
Severity
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/
Summary
CONPROSYS HMI System (CHS) Ver.3.4.4?and earlier allows a remote unauthenticated attacker to execute an arbitrary OS command on the server where the product is running by sending a specially crafted request.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| contec | conprosys_hmi_system | * |
{
"affected": [
{
"affectedData": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "Ver.3.4.4?and earlier"
}
]
}
],
"source": "vultures@jpcert.or.jp"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93E9C119-AA5E-49A3-B2AB-5098984FA24C",
"versionEndIncluding": "3.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "CONPROSYS HMI System (CHS) Ver.3.4.4?and earlier allows a remote unauthenticated attacker to execute an arbitrary OS command on the server where the product is running by sending a specially crafted request."
},
{
"lang": "es",
"value": "CONPROSYS HMI System (CHS) Ver.3.4.4 y versiones anteriores permiten que un atacante remoto no autenticado ejecute un comando arbitrario del sistema operativo en el servidor donde se ejecuta el producto mediante el env\u00edo de una solicitud especialmente manipulada."
}
],
"id": "CVE-2022-44456",
"lastModified": "2026-06-17T05:08:23.827",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-44456",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-17T14:41:38.031393Z",
"version": "2.0.3"
}
}
]
},
"published": "2022-12-19T03:15:10.690",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://jvn.jp/en/vu/JVNVU96873821/index.html"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_221014_en.pdf"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://jvn.jp/en/vu/JVNVU96873821/index.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_221014_en.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.contec.com/download/contract/contract4/?itemid=ea8039aa-3434-4999-9ab6-897aa690210c\u0026downloaditemid=866d7d3c-aae9-438d-87f3-17aa040df90b"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
JVNDB-2026-033235
Vulnerability from jvndb - Published: 2026-09-14 07:32 - Updated:2026-09-29 03:18
Severity
Summary
Multiple vulnerabilities in Contec CONPROSYS series
Details
CONPROSYS series provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.
- Cross-site scripting (CWE-79) - CVE-2026-82773, CVE-2026-82776, CVE-2026-82788
- OS command injection (CWE-78) - CVE-2026-82774, CVE-2026-82777, CVE-2026-82779
- Exposure of information through directory listing (CWE-548) - CVE-2026-82775, CVE-2026-82778
- Dependency on vulnerable third-party component (CWE-1395)
- This issue is caused by a vulnerability in chart.js (CVE-2020-7746).
- Unrestricted upload of file with dangerous type (CWE-434) - CVE-2026-82780
- Cross-site scripting (CWE-79) - CVE-2026-82781
- Out-of-bounds write (CWE-787) - CVE-2026-82782
- Cross-site request forgery (CWE-352) - CVE-2026-82764
- Plaintext storage of a password (CWE-256) - CVE-2026-82783
- Missing authentication for critical function (CWE-306) - CVE-2026-82784
- Stack-based buffer overflow (CWE-121) - CVE-2026-82785
- Insufficiently protected credentials (CWE-522) - CVE-2026-82786
- Missing authentication for critical function (CWE-306) - CVE-2026-82787
- Eval injection (CWE-95) - CVE-2026-82789
References
Impacted products
| Vendor | Product | |||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-033235.html",
"dc:date": "2026-09-29T12:18+09:00",
"dcterms:issued": "2026-09-14T16:32+09:00",
"dcterms:modified": "2026-09-29T12:18+09:00",
"description": "CONPROSYS series provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.\u003ca href=\u0027https://cwe.mitre.org/data/definitions/79.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/78.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/548.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/1395.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://www.cve.org/CVERecord?id=CVE-2020-7746\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/434.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/79.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/787.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/352.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/256.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/306.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/121.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/522.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/306.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/95.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003cul\u003e\u003cli\u003eCross-site scripting (CWE-79) - CVE-2026-82773, CVE-2026-82776, CVE-2026-82788\u003c/li\u003e\u003cli\u003eOS command injection (CWE-78) - CVE-2026-82774, CVE-2026-82777, CVE-2026-82779\u003c/li\u003e\u003cli\u003eExposure of information through directory listing (CWE-548) - CVE-2026-82775, CVE-2026-82778\u003c/li\u003e\u003cli\u003eDependency on vulnerable third-party component (CWE-1395)\u003c/li\u003e\u003cul\u003e\u003cli\u003eThis issue is caused by a vulnerability in chart.js (CVE-2020-7746).\u003c/li\u003e\u003c/ul\u003e\u003cli\u003eUnrestricted upload of file with dangerous type (CWE-434) - CVE-2026-82780\u003c/li\u003e\u003cli\u003eCross-site scripting (CWE-79) - CVE-2026-82781\u003c/li\u003e\u003cli\u003eOut-of-bounds write (CWE-787) - CVE-2026-82782\u003c/li\u003e\u003cli\u003eCross-site request forgery (CWE-352) - CVE-2026-82764\u003c/li\u003e\u003cli\u003ePlaintext storage of a password (CWE-256) - CVE-2026-82783\u003c/li\u003e\u003cli\u003eMissing authentication for critical function (CWE-306) - CVE-2026-82784\u003c/li\u003e\u003cli\u003eStack-based buffer overflow (CWE-121) - CVE-2026-82785\u003c/li\u003e\u003cli\u003eInsufficiently protected credentials (CWE-522) - CVE-2026-82786\u003c/li\u003e\u003cli\u003eMissing authentication for critical function (CWE-306) - CVE-2026-82787\u003c/li\u003e\u003cli\u003eEval injection (CWE-95) - CVE-2026-82789\u003c/li\u003e\u003c/ul\u003eContec Co., Ltd. reported these vulnerabilities to JPCERT/CC to notify users of the solutions through JVN.",
"link": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-033235.html",
"sec:cpe": [
{
"#text": "cpe:/a:contec:conprosys_hmi_system",
"@product": "CONPROSYS HMI System (CHS)",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:configurable_type_cps-pcs341_-ds1-120",
"@product": "Configurable type CPS-PCS341[][]-DS1-1201",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:cps-tm341g5mb-adsc1-931",
"@product": "CPS-TM341G5MB-ADSC1-931",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:cps-tm341gmb-adsc1-931",
"@product": "CPS-TM341GMB-ADSC1-931",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:cps-tm341mb-adsc1-931",
"@product": "CPS-TM341MB-ADSC1-931",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:cpsl-08p1en",
"@product": "CPSL-08P1EN",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:cpsn-eob471ei-",
"@product": "Remote I/O Coupler Unit (EtherNet/IP Adapter) CPSN-EOB471EI-[]1",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:cpsn-mcb271-",
"@product": "Remote I/O Coupler Unit (Server Type) CPSN-MCB271-*",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:cpsn-pcb271-s1-041",
"@product": "Programmable Remote I/O Coupler Unit (Software PLC Type) CPSN-PCB271-S1-041",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:integrated_type_cps-pc341_-9201",
"@product": "Integrated Type CPS-PC341[][]-*-9201",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:m2m_controller_configurable_type_cps-mcs341",
"@product": "M2M Controller Configurable type CPS-MCS341*",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:m2m_controller_integrated_type_cps-mc341",
"@product": "M2M Controller Integrated Type CPS-MC341",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:m2m_gateway_configurable_type_cps-mgs341",
"@product": "M2M Gateway Configurable type CPS-MGS341*",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:m2m_gateway_integrated_type_cps-mg341",
"@product": "M2M Gateway Integrated Type CPS-MG341*",
"@vendor": "Contec",
"@version": "2.2"
}
],
"sec:cvss": {
"@score": "6.1",
"@severity": "Medium",
"@type": "Base",
"@vector": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"@version": "3.0"
},
"sec:identifier": "JVNDB-2026-033235",
"sec:references": [
{
"#text": "https://jvn.jp/en/vu/JVNVU96551518/index.html",
"@id": "JVNVU#96551518",
"@source": "JVN"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2020-7746",
"@id": "CVE-2020-7746",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82764",
"@id": "CVE-2026-82764",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82773",
"@id": "CVE-2026-82773",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82774",
"@id": "CVE-2026-82774",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82775",
"@id": "CVE-2026-82775",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82776",
"@id": "CVE-2026-82776",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82777",
"@id": "CVE-2026-82777",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82778",
"@id": "CVE-2026-82778",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82779",
"@id": "CVE-2026-82779",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82780",
"@id": "CVE-2026-82780",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82781",
"@id": "CVE-2026-82781",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82782",
"@id": "CVE-2026-82782",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82783",
"@id": "CVE-2026-82783",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82784",
"@id": "CVE-2026-82784",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82785",
"@id": "CVE-2026-82785",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82786",
"@id": "CVE-2026-82786",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82787",
"@id": "CVE-2026-82787",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82788",
"@id": "CVE-2026-82788",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82789",
"@id": "CVE-2026-82789",
"@source": "CVE"
},
{
"#text": "https://cwe.mitre.org/data/definitions/121.html",
"@id": "CWE-121",
"@title": "Stack-based Buffer Overflow(CWE-121)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/1395.html",
"@id": "CWE-1395",
"@title": "Dependency on Vulnerable Third-Party Component(CWE-1395)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/256.html",
"@id": "CWE-256",
"@title": "Unprotected Storage of Credentials(CWE-256)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/306.html",
"@id": "CWE-306",
"@title": "Missing Authentication for Critical Function(CWE-306)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-352",
"@title": "Cross-Site Request Forgery(CWE-352)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/434.html",
"@id": "CWE-434",
"@title": "Unrestricted Upload of File with Dangerous Type(CWE-434)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/522.html",
"@id": "CWE-522",
"@title": "Insufficiently Protected Credentials(CWE-522)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/548.html",
"@id": "CWE-548",
"@title": "Exposure of Information Through Directory Listing(CWE-548)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-78",
"@title": "OS Command Injection(CWE-78)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/787.html",
"@id": "CWE-787",
"@title": "Out-of-bounds Write(CWE-787)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-79",
"@title": "Cross-site Scripting(CWE-79)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/95.html",
"@id": "CWE-95",
"@title": "Improper Neutralization of Directives in Dynamically Evaluated Code (\u0027Eval Injection\u0027)(CWE-95)"
}
],
"title": "Multiple vulnerabilities in Contec CONPROSYS series"
}
JVNDB-2026-033234
Vulnerability from jvndb - Published: 2026-09-14 07:32 - Updated:2026-09-15 03:40
Severity
Summary
Multiple vulnerabilities in Contec FLEXLAN series
Details
FLEXLAN series provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.
- OS command injection (CWE-78) - CVE-2026-82762, CVE-2026-82766
- Cross-site scripting (CWE-79) - CVE-2026-82763, CVE-2026-82769, CVE-2026-82771
- Cross-site request forgery (CWE-352) - CVE-2026-82764
- Path traversal (CWE-23) - CVE-2026-82765, CVE-2026-82768
- Cross-site scripting (CWE-79) - CVE-2026-82767
- Buffer overflow (CWE-120) - CVE-2026-82770, CVE-2026-82772
References
| Type | URL | ||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
Impacted products
| Vendor | Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-033234.html",
"dc:date": "2026-09-15T12:40+09:00",
"dcterms:issued": "2026-09-14T16:32+09:00",
"dcterms:modified": "2026-09-15T12:40+09:00",
"description": "FLEXLAN series provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.\u003ca href=\u0027https://cwe.mitre.org/data/definitions/78.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/79.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/352.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/23.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/79.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/120.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003cul\u003e\u003cli\u003eOS command injection (CWE-78) - CVE-2026-82762, CVE-2026-82766\u003c/li\u003e\u003cli\u003eCross-site scripting (CWE-79) - CVE-2026-82763, CVE-2026-82769, CVE-2026-82771\u003c/li\u003e\u003cli\u003eCross-site request forgery (CWE-352) - CVE-2026-82764\u003c/li\u003e\u003cli\u003ePath traversal (CWE-23) - CVE-2026-82765, CVE-2026-82768\u003c/li\u003e\u003cli\u003eCross-site scripting (CWE-79) - CVE-2026-82767\u003c/li\u003e\u003cli\u003eBuffer overflow (CWE-120) - CVE-2026-82770, CVE-2026-82772\u003c/li\u003e\u003c/ul\u003eContec Co., Ltd. reported these vulnerabilities to JPCERT/CC to notify users of the solutions through JVN.",
"link": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-033234.html",
"sec:cpe": [
{
"#text": "cpe:/h:contec:ece1000",
"@product": "ECE1000",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:ece1020",
"@product": "ECE1020",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:ecs1020",
"@product": "ECS1020",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxa3000",
"@product": "FXA3000",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxa3000-",
"@product": "FXA3000-[][]",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxa3020",
"@product": "FXA3020",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxa3020-",
"@product": "FXA3020-[][]",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxa3200",
"@product": "FXA3200",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxa5000",
"@product": "FXA5000",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxa5020",
"@product": "FXA5020",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxa5020-",
"@product": "FXA5020-[][]",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxe3000",
"@product": "FXE3000",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxe3000-",
"@product": "FXE3000-[][]",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxe3000-wp",
"@product": "FXE3000-WP",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxe4000",
"@product": "FXE4000",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxe4000-wp",
"@product": "FXE4000-WP",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxe5000",
"@product": "FXE5000",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxe5000-",
"@product": "FXE5000-[][]",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxs300_-cn",
"@product": "FXS300[]-CN",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxs4000",
"@product": "FXS4000",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxs4020",
"@product": "FXS4020",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxs5000-",
"@product": "FXS5000-[][]",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:fxs5021",
"@product": "FXS5021",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:rp-wah-sr1",
"@product": "RP-WAH-SR1",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:rp-wah-sr12",
"@product": "RP-WAH-SR12",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:rp-wah-sr2",
"@product": "RP-WAH-SR2",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:rp-wah-sr22",
"@product": "RP-WAH-SR22",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:sga1000",
"@product": "SGA1000",
"@vendor": "Contec",
"@version": "2.2"
}
],
"sec:cvss": {
"@score": "8.8",
"@severity": "High",
"@type": "Base",
"@vector": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"@version": "3.0"
},
"sec:identifier": "JVNDB-2026-033234",
"sec:references": [
{
"#text": "https://jvn.jp/en/vu/JVNVU99009004/index.html",
"@id": "JVNVU#99009004",
"@source": "JVN"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82762",
"@id": "CVE-2026-82762",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82763",
"@id": "CVE-2026-82763",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82764",
"@id": "CVE-2026-82764",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82765",
"@id": "CVE-2026-82765",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82766",
"@id": "CVE-2026-82766",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82767",
"@id": "CVE-2026-82767",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82768",
"@id": "CVE-2026-82768",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82769",
"@id": "CVE-2026-82769",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82770",
"@id": "CVE-2026-82770",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82771",
"@id": "CVE-2026-82771",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82772",
"@id": "CVE-2026-82772",
"@source": "CVE"
},
{
"#text": "https://cwe.mitre.org/data/definitions/120.html",
"@id": "CWE-120",
"@title": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)(CWE-120)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/23.html",
"@id": "CWE-23",
"@title": "Relative Path Traversal(CWE-23)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-352",
"@title": "Cross-Site Request Forgery(CWE-352)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-78",
"@title": "OS Command Injection(CWE-78)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-79",
"@title": "Cross-site Scripting(CWE-79)"
}
],
"title": "Multiple vulnerabilities in Contec FLEXLAN series"
}
JVNDB-2026-032931
Vulnerability from jvndb - Published: 2026-09-14 07:32 - Updated:2026-09-14 07:32
Severity
Summary
Multiple vulnerabilities in Contec PC-HELPER series
Details
PC-HELPER series provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.
- Cross-site scripting (CWE-79) - CVE-2026-82790
- Cross-site request forgery (CWE-352) - CVE-2026-82764
- OS command injection (CWE-78) - CVE-2026-82791
- Cross-site scripting (CWE-79) - CVE-2026-82792
- Unrestricted upload of file with dangerous type (CWE-434) - CVE-2026-82793
References
| Type | URL | |||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||
Impacted products
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-032931.html",
"dc:date": "2026-09-14T16:32+09:00",
"dcterms:issued": "2026-09-14T16:32+09:00",
"dcterms:modified": "2026-09-14T16:32+09:00",
"description": "PC-HELPER series provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.\u003ca href=\u0027https://cwe.mitre.org/data/definitions/79.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/352.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/78.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/79.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/434.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003cul\u003e\u003cli\u003eCross-site scripting (CWE-79) - CVE-2026-82790\u003c/li\u003e\u003cli\u003eCross-site request forgery (CWE-352) - CVE-2026-82764\u003c/li\u003e\u003cli\u003eOS command injection (CWE-78) - CVE-2026-82791\u003c/li\u003e\u003cli\u003eCross-site scripting (CWE-79) - CVE-2026-82792\u003c/li\u003e\u003cli\u003eUnrestricted upload of file with dangerous type (CWE-434) - CVE-2026-82793\u003c/li\u003e\u003c/ul\u003eContec Co., Ltd. reported these vulnerabilities to JPCERT/CC to notify users of the solutions through JVN.",
"link": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-032931.html",
"sec:cpe": [
{
"#text": "cpe:/h:contec:can-2-usb",
"@product": "CAN 2.0B Communication Wireless LAN / USB Converter Unit CAN-2-USB",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:can-2-wf",
"@product": "CAN 2.0B Communication Wireless LAN / USB Converter Unit CAN-2-WF",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:dio-0404ry-lwf",
"@product": "PC-HELPER Wireless I/O DIO-0404RY-LWF",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/h:contec:dio-0404ry-lwf-us",
"@product": "PC-HELPER Wireless I/O DIO-0404RY-LWF-US",
"@vendor": "Contec",
"@version": "2.2"
}
],
"sec:cvss": {
"@score": "5.4",
"@severity": "Medium",
"@type": "Base",
"@vector": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"@version": "3.0"
},
"sec:identifier": "JVNDB-2026-032931",
"sec:references": [
{
"#text": "https://jvn.jp/en/vu/JVNVU90314828/index.html",
"@id": "JVNVU#90314828",
"@source": "JVN"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82764",
"@id": "CVE-2026-82764",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82790",
"@id": "CVE-2026-82790",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82791",
"@id": "CVE-2026-82791",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82792",
"@id": "CVE-2026-82792",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82793",
"@id": "CVE-2026-82793",
"@source": "CVE"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-352",
"@title": "Cross-Site Request Forgery(CWE-352)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/434.html",
"@id": "CWE-434",
"@title": "Unrestricted Upload of File with Dangerous Type(CWE-434)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-78",
"@title": "OS Command Injection(CWE-78)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-79",
"@title": "Cross-site Scripting(CWE-79)"
}
],
"title": "Multiple vulnerabilities in Contec PC-HELPER series"
}
JVNDB-2026-032930
Vulnerability from jvndb - Published: 2026-09-14 07:32 - Updated:2026-09-14 07:32
Severity
Summary
Multiple vulnerabilities in SolarView Compact
Details
SolarView Compact provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.
- OS command injection in Schedule Settings (CWE-78) - CVE-2026-82794
- Cross-site scripting in Schedule Settings and Mail Send Setting (CWE-79) - CVE-2026-82795
- Cross-site scripting in Image Management (CWE-79) - CVE-2026-82796
References
| Type | URL | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-032930.html",
"dc:date": "2026-09-14T16:32+09:00",
"dcterms:issued": "2026-09-14T16:32+09:00",
"dcterms:modified": "2026-09-14T16:32+09:00",
"description": "SolarView Compact provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.\u003ca href=\u0027https://cwe.mitre.org/data/definitions/78.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/79.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003ca href=\u0027https://cwe.mitre.org/data/definitions/79.html\u0027 target=\u0027_blank\u0027\u003e\u003c/a\u003e\u003cul\u003e\u003cli\u003eOS command injection in Schedule Settings (CWE-78) - CVE-2026-82794\u003c/li\u003e\u003cli\u003eCross-site scripting in Schedule Settings and Mail Send Setting (CWE-79) - CVE-2026-82795\u003c/li\u003e\u003cli\u003eCross-site scripting in Image Management (CWE-79) - CVE-2026-82796\u003c/li\u003e\u003c/ul\u003eContec Co., Ltd. reported these vulnerabilities to JPCERT/CC to notify users of the solutions through JVN.",
"link": "https://jvndb.jvn.jp/en/contents/2026/JVNDB-2026-032930.html",
"sec:cpe": [
{
"#text": "cpe:/o:contec:sv-cpt-mc310f_firmware",
"@product": "SolarView Compact SV-CPT-MC310F",
"@vendor": "Contec",
"@version": "2.2"
},
{
"#text": "cpe:/o:contec:sv-cpt-mc310_firmware",
"@product": "SolarView Compact SV-CPT-MC310",
"@vendor": "Contec",
"@version": "2.2"
}
],
"sec:cvss": {
"@score": "8.8",
"@severity": "High",
"@type": "Base",
"@vector": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"@version": "3.0"
},
"sec:identifier": "JVNDB-2026-032930",
"sec:references": [
{
"#text": "https://jvn.jp/en/vu/JVNVU97753461/index.html",
"@id": "JVNVU#97753461",
"@source": "JVN"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82794",
"@id": "CVE-2026-82794",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82795",
"@id": "CVE-2026-82795",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2026-82796",
"@id": "CVE-2026-82796",
"@source": "CVE"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-78",
"@title": "OS Command Injection(CWE-78)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-79",
"@title": "Cross-site Scripting(CWE-79)"
}
],
"title": "Multiple vulnerabilities in SolarView Compact"
}
JVNDB-2025-007754
Vulnerability from jvndb - Published: 2025-07-02 02:31 - Updated:2025-07-02 02:31
Severity
Summary
Multiple vulnerabilities in Contec CONPROSYS HMI System (CHS)
Details
CONPROSYS HMI System (CHS) provided by Contec Co.,Ltd. contains multiple vulnerabilities listed below.
* Reflected cross-site scripting (CWE-79) - CVE-2025-34080
* Insertion of sensitive information into debugging code (CWE-215) - CVE-2025-34081
Alex Williams of Converge Technology Solutions reported these vulnerabilities to Vulncheck Inc., and
Vulncheck Inc. reported these vulnerabilities to the developer.
Based on the coordination request made by the developer, JPCERT/CC coordinated with Vulncheck Inc. and the developer.
References
| Type | URL | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | |
|---|---|---|
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2025/JVNDB-2025-007754.html",
"dc:date": "2025-07-02T11:31+09:00",
"dcterms:issued": "2025-07-02T11:31+09:00",
"dcterms:modified": "2025-07-02T11:31+09:00",
"description": "CONPROSYS HMI System (CHS) provided by Contec Co.,Ltd. contains multiple vulnerabilities listed below.\r\n\r\n * Reflected cross-site scripting (CWE-79) - CVE-2025-34080\r\n * Insertion of sensitive information into debugging code (CWE-215) - CVE-2025-34081\r\n\r\nAlex Williams of Converge Technology Solutions reported these vulnerabilities to Vulncheck Inc., and\r\nVulncheck Inc. reported these vulnerabilities to the developer.\r\nBased on the coordination request made by the developer, JPCERT/CC coordinated with Vulncheck Inc. and the developer.",
"link": "https://jvndb.jvn.jp/en/contents/2025/JVNDB-2025-007754.html",
"sec:cpe": {
"#text": "cpe:/a:contec:conprosys_hmi_system",
"@product": "CONPROSYS HMI System (CHS)",
"@vendor": "Contec",
"@version": "2.2"
},
"sec:cvss": {
"@score": "6.1",
"@severity": "Medium",
"@type": "Base",
"@vector": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"@version": "3.0"
},
"sec:identifier": "JVNDB-2025-007754",
"sec:references": [
{
"#text": "https://jvn.jp/en/vu/JVNVU92266386/index.html",
"@id": "JVNVU#92266386",
"@source": "JVN"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2025-34080",
"@id": "CVE-2025-34080",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2025-34081",
"@id": "CVE-2025-34081",
"@source": "CVE"
},
{
"#text": "https://cwe.mitre.org/data/definitions/215.html",
"@id": "CWE-215",
"@title": "Insertion of Sensitive Information Into Debugging Code(CWE-215)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-79",
"@title": "Cross-site Scripting(CWE-79)"
}
],
"title": "Multiple vulnerabilities in Contec CONPROSYS HMI System (CHS)"
}
JVNDB-2023-002002
Vulnerability from jvndb - Published: 2023-06-01 04:48 - Updated:2024-03-19 09:13
Severity
Summary
Multiple vulnerabilities in Contec CONPROSYS HMI System (CHS)
Details
CONPROSYS HMI System (CHS) provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.
* Plaintext storage of a password (CWE-256) - CVE-2023-28713
* Incorrect permission assignment for critical resource (CWE-732) - CVE-2023-28399
* Improper access control (CWE-284) - CVE-2023-28657
* Cross-site scripting (CWE-79) - CVE-2023-28651
* Server-side request forgery (CWE-918)- CVE-2023-28824
* SQL injection (CWE-89) - CVE-2023-29154
* Improper control of interaction frequency (CWE-799) - CVE-2023-2758
Michael Heinzl reported the vulnerabilities listed below to JPCERT/CC, and JPCERT/CC coordinated with the developer.
CVE-2023-28713, CVE-2023-28399, CVE-2023-28657, CVE-2023-28651, CVE-2023-28824, CVE-2023-29154
Tenable, Inc. reported CVE-2023-2758 vulnerability to the developer, and based on the coordination request made by the developer, JPCERT/CC coordinated with Tenable, Inc. and the developer.
References
| Type | URL | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Impacted products
| Vendor | Product | |
|---|---|---|
{
"@rdf:about": "https://jvndb.jvn.jp/en/contents/2023/JVNDB-2023-002002.html",
"dc:date": "2024-03-19T18:13+09:00",
"dcterms:issued": "2023-06-01T13:48+09:00",
"dcterms:modified": "2024-03-19T18:13+09:00",
"description": "CONPROSYS HMI System (CHS) provided by Contec Co., Ltd. contains multiple vulnerabilities listed below.\r\n\r\n* Plaintext storage of a password (CWE-256) - CVE-2023-28713\r\n* Incorrect permission assignment for critical resource (CWE-732) - CVE-2023-28399\r\n* Improper access control (CWE-284) - CVE-2023-28657\r\n* Cross-site scripting (CWE-79) - CVE-2023-28651\r\n* Server-side request forgery (CWE-918)- CVE-2023-28824\r\n* SQL injection (CWE-89) - CVE-2023-29154\r\n* Improper control of interaction frequency (CWE-799) - CVE-2023-2758\r\n\r\nMichael Heinzl reported the vulnerabilities listed below to JPCERT/CC, and JPCERT/CC coordinated with the developer.\r\nCVE-2023-28713, CVE-2023-28399, CVE-2023-28657, CVE-2023-28651, CVE-2023-28824, CVE-2023-29154\r\n\r\nTenable, Inc. reported CVE-2023-2758 vulnerability to the developer, and based on the coordination request made by the developer, JPCERT/CC coordinated with Tenable, Inc. and the developer.",
"link": "https://jvndb.jvn.jp/en/contents/2023/JVNDB-2023-002002.html",
"sec:cpe": {
"#text": "cpe:/a:contec:conprosys_hmi_system",
"@product": "CONPROSYS HMI System (CHS)",
"@vendor": "Contec",
"@version": "2.2"
},
"sec:cvss": {
"@score": "8.8",
"@severity": "High",
"@type": "Base",
"@vector": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"@version": "3.0"
},
"sec:identifier": "JVNDB-2023-002002",
"sec:references": [
{
"#text": "https://jvn.jp/en/vu/JVNVU93372935/index.html",
"@id": "JVNVU#93372935",
"@source": "JVN"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-28713",
"@id": "CVE-2023-28713",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-28399",
"@id": "CVE-2023-28399",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-28657",
"@id": "CVE-2023-28657",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-28651",
"@id": "CVE-2023-28651",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-28824",
"@id": "CVE-2023-28824",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-29154",
"@id": "CVE-2023-29154",
"@source": "CVE"
},
{
"#text": "https://www.cve.org/CVERecord?id=CVE-2023-2758",
"@id": "CVE-2023-2758",
"@source": "CVE"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-2758",
"@id": "CVE-2023-2758",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-28399",
"@id": "CVE-2023-28399",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-28651",
"@id": "CVE-2023-28651",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-28657",
"@id": "CVE-2023-28657",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-28713",
"@id": "CVE-2023-28713",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-28824",
"@id": "CVE-2023-28824",
"@source": "NVD"
},
{
"#text": "https://nvd.nist.gov/vuln/detail/CVE-2023-29154",
"@id": "CVE-2023-29154",
"@source": "NVD"
},
{
"#text": "https://cwe.mitre.org/data/definitions/256.html",
"@id": "CWE-256",
"@title": "Unprotected Storage of Credentials(CWE-256)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/284.html",
"@id": "CWE-284",
"@title": "Improper Access Control(CWE-284)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/732.html",
"@id": "CWE-732",
"@title": "Incorrect Permission Assignment for Critical Resource(CWE-732)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-79",
"@title": "Cross-site Scripting(CWE-79)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/799.html",
"@id": "CWE-799",
"@title": "Improper Control of Interaction Frequency(CWE-799)"
},
{
"#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
"@id": "CWE-89",
"@title": "SQL Injection(CWE-89)"
},
{
"#text": "https://cwe.mitre.org/data/definitions/918.html",
"@id": "CWE-918",
"@title": "Server-Side Request Forgery (SSRF)(CWE-918)"
}
],
"title": "Multiple vulnerabilities in Contec CONPROSYS HMI System (CHS)"
}
CVE-2026-82789 (GCVE-0-2026-82789)
Vulnerability from nvd – Published: 2026-09-14 06:44 – Updated: 2026-09-14 15:45
VLAI
EPSS
VEX
Summary
An improper neutralization of directives in dynamically evaluated code ('Eval Injection') issue exists in CONPROSYS HMI System(CHS). If exploited, arbitrary code may be executed by an attacker who can log in to the product.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 15:38 UTC
CWE
- CWE-95 - Improper neutralization of directives in dynamically evaluated code ('Eval Injection')
Assigner
References
2 references
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Contec | CONPROSYS HMI System(CHS) |
Affected:
0 , < 3.8.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82789",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T15:38:44.904489Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T15:45:31.910Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CONPROSYS HMI System(CHS)",
"vendor": "Contec",
"versions": [
{
"lessThan": "3.8.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper neutralization of directives in dynamically evaluated code (\u0027Eval Injection\u0027) issue exists in CONPROSYS HMI System(CHS). If exploited, arbitrary code may be executed by an attacker who can log in to the product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-95",
"description": "Improper neutralization of directives in dynamically evaluated code (\u0027Eval Injection\u0027)",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T06:44:56.367Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_cps_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU96551518/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82789",
"datePublished": "2026-09-14T06:44:56.367Z",
"dateReserved": "2026-08-31T02:30:58.279Z",
"dateUpdated": "2026-09-14T15:45:31.910Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-34081 (GCVE-0-2025-34081)
Vulnerability from nvd – Published: 2025-07-01 17:56 – Updated: 2025-11-21 19:24
VLAI
EPSS
VEX
Title
CONPROSYS HMI System (CHS) < 3.7.7 Exposed PHP Debug Info
Summary
The Contec Co.,Ltd. CONPROSYS HMI System (CHS) exposes a PHP phpinfo() debug page to unauthenticated users that may contain sensitive data useful for an attacker.This issue affects CONPROSYS HMI System (CHS): before 3.7.7.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-01 18:48 UTC
CWE
- CWE-215 - Insertion of Sensitive Information Into Debugging Code
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://jvn.jp/en/vu/JVNVU92266386/ | third-party-advisory |
| https://www.vulncheck.com/advisories/conprosys-hm… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co.,Ltd. | CONPROSYS HMI System (CHS) |
Affected:
0 , < 3.7.7
(semver)
cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-34081",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-01T18:48:45.941957Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-01T18:48:56.610Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co.,Ltd.",
"versions": [
{
"lessThan": "3.7.7",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.7.7",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Alex Williams of Converge Technology Solutions"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Contec Co.,Ltd. CONPROSYS HMI System (CHS) exposes a PHP phpinfo() debug page to unauthenticated users that may contain sensitive data useful for an attacker.\u003cp\u003eThis issue affects CONPROSYS HMI System (CHS): before 3.7.7.\u003c/p\u003e"
}
],
"value": "The Contec Co.,Ltd. CONPROSYS HMI System (CHS) exposes a PHP phpinfo() debug page to unauthenticated users that may contain sensitive data useful for an attacker.This issue affects CONPROSYS HMI System (CHS): before 3.7.7."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37 Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-215",
"description": "CWE-215 Insertion of Sensitive Information Into Debugging Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-21T19:24:57.237Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU92266386/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/conprosys-hmi-system-exposed-php-debug-info"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "CONPROSYS HMI System (CHS) \u003c 3.7.7 Exposed PHP Debug Info",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-34081",
"datePublished": "2025-07-01T17:56:56.073Z",
"dateReserved": "2025-04-15T19:15:22.551Z",
"dateUpdated": "2025-11-21T19:24:57.237Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-34080 (GCVE-0-2025-34080)
Vulnerability from nvd – Published: 2025-07-01 17:51 – Updated: 2025-11-21 19:25
VLAI
EPSS
VEX
Title
CONPROSYS HMI System (CHS) < 3.7.7 Reflected Cross-Site Scripting
Summary
The Contec Co.,Ltd. CONPROSYS HMI System (CHS) is vulnerable to Cross-Site Scripting (XSS) in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.This issue affects CONPROSYS HMI System (CHS): before 3.7.7.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-01 18:47 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://jvn.jp/en/vu/JVNVU92266386/ | third-party-advisory |
| https://www.vulncheck.com/advisories/conprosys-hm… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co.,Ltd. | CONPROSYS HMI System (CHS) |
Affected:
0 , < 3.7.7
(semver)
cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-34080",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-01T18:47:11.611812Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-01T18:47:23.334Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"modules": [
"getqsetting.php"
],
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co.,Ltd.",
"versions": [
{
"lessThan": "3.7.7",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.7.7",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Alex Williams of Converge Technology Solutions"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Contec Co.,Ltd. CONPROSYS HMI System (CHS) is vulnerable to Cross-Site Scripting (XSS) in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.\u003cp\u003eThis issue affects CONPROSYS HMI System (CHS): before 3.7.7.\u003c/p\u003e"
}
],
"value": "The Contec Co.,Ltd. CONPROSYS HMI System (CHS) is vulnerable to Cross-Site Scripting (XSS) in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.This issue affects CONPROSYS HMI System (CHS): before 3.7.7."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-21T19:25:27.043Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU92266386/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/conprosys-hmi-system-reflected-xss"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "CONPROSYS HMI System (CHS) \u003c 3.7.7 Reflected Cross-Site Scripting",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-34080",
"datePublished": "2025-07-01T17:51:53.979Z",
"dateReserved": "2025-04-15T19:15:22.550Z",
"dateUpdated": "2025-11-21T19:25:27.043Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-46509 (GCVE-0-2023-46509)
Vulnerability from nvd – Published: 2023-10-27 00:00 – Updated: 2024-09-12 14:13
VLAI
EPSS
VEX
Summary
An issue in Contec SolarView Compact v.6.0 and before allows an attacker to execute arbitrary code via the texteditor.php component.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-10 14:15 UTC
CWE
- n/a
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| contec | solarview_compact |
Affected:
0 , ≤ 6.0
(custom)
cpe:2.3:h:contec:solarview_compact:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:45:42.270Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://gist.github.com/ATonysan/d6f72e9eb90407d64bed4566aa80afb1#file-cve-2023-46509"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:contec:solarview_compact:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "solarview_compact",
"vendor": "contec",
"versions": [
{
"lessThanOrEqual": "6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-46509",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T14:15:34.861950Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-12T14:13:31.239Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in Contec SolarView Compact v.6.0 and before allows an attacker to execute arbitrary code via the texteditor.php component."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-27T20:40:22.919Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://gist.github.com/ATonysan/d6f72e9eb90407d64bed4566aa80afb1#file-cve-2023-46509"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-46509",
"datePublished": "2023-10-27T00:00:00.000Z",
"dateReserved": "2023-10-23T00:00:00.000Z",
"dateUpdated": "2024-09-12T14:13:31.239Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29154 (GCVE-0-2023-29154)
Vulnerability from nvd – Published: 2023-06-01 00:00 – Updated: 2025-01-09 19:24
VLAI
EPSS
VEX
Summary
SQL injection vulnerability exists in the CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-09 19:24 UTC
CWE
- SQL Injection
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co., Ltd. | CONPROSYS HMI System (CHS) |
Affected:
versions prior to 3.5.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:00:15.588Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-29154",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-09T19:24:32.817341Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-09T19:24:43.251Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "versions prior to 3.5.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SQL injection vulnerability exists in the CONPROSYS HMI System (CHS) versions prior to 3.5.3. A user who can access the affected product with an administrative privilege may execute an arbitrary SQL command via specially crafted input to the query setting page."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "SQL Injection",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-01T00:00:00.000Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_en.pdf"
},
{
"url": "https://www.contec.com/jp/api/downloadlogger?download=/-/media/Contec/jp/support/security-info/contec_security_chs_230531_jp.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU93372935/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2023-29154",
"datePublished": "2023-06-01T00:00:00.000Z",
"dateReserved": "2023-05-11T00:00:00.000Z",
"dateUpdated": "2025-01-09T19:24:43.251Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-82789 (GCVE-0-2026-82789)
Vulnerability from cvelistv5 – Published: 2026-09-14 06:44 – Updated: 2026-09-14 15:45
VLAI
EPSS
VEX
Summary
An improper neutralization of directives in dynamically evaluated code ('Eval Injection') issue exists in CONPROSYS HMI System(CHS). If exploited, arbitrary code may be executed by an attacker who can log in to the product.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 15:38 UTC
CWE
- CWE-95 - Improper neutralization of directives in dynamically evaluated code ('Eval Injection')
Assigner
References
2 references
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Contec | CONPROSYS HMI System(CHS) |
Affected:
0 , < 3.8.0
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82789",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T15:38:44.904489Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T15:45:31.910Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CONPROSYS HMI System(CHS)",
"vendor": "Contec",
"versions": [
{
"lessThan": "3.8.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper neutralization of directives in dynamically evaluated code (\u0027Eval Injection\u0027) issue exists in CONPROSYS HMI System(CHS). If exploited, arbitrary code may be executed by an attacker who can log in to the product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-95",
"description": "Improper neutralization of directives in dynamically evaluated code (\u0027Eval Injection\u0027)",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T06:44:56.367Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_cps_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU96551518/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82789",
"datePublished": "2026-09-14T06:44:56.367Z",
"dateReserved": "2026-08-31T02:30:58.279Z",
"dateUpdated": "2026-09-14T15:45:31.910Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-34081 (GCVE-0-2025-34081)
Vulnerability from cvelistv5 – Published: 2025-07-01 17:56 – Updated: 2025-11-21 19:24
VLAI
EPSS
VEX
Title
CONPROSYS HMI System (CHS) < 3.7.7 Exposed PHP Debug Info
Summary
The Contec Co.,Ltd. CONPROSYS HMI System (CHS) exposes a PHP phpinfo() debug page to unauthenticated users that may contain sensitive data useful for an attacker.This issue affects CONPROSYS HMI System (CHS): before 3.7.7.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-01 18:48 UTC
CWE
- CWE-215 - Insertion of Sensitive Information Into Debugging Code
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://jvn.jp/en/vu/JVNVU92266386/ | third-party-advisory |
| https://www.vulncheck.com/advisories/conprosys-hm… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co.,Ltd. | CONPROSYS HMI System (CHS) |
Affected:
0 , < 3.7.7
(semver)
cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-34081",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-01T18:48:45.941957Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-01T18:48:56.610Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co.,Ltd.",
"versions": [
{
"lessThan": "3.7.7",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.7.7",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Alex Williams of Converge Technology Solutions"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Contec Co.,Ltd. CONPROSYS HMI System (CHS) exposes a PHP phpinfo() debug page to unauthenticated users that may contain sensitive data useful for an attacker.\u003cp\u003eThis issue affects CONPROSYS HMI System (CHS): before 3.7.7.\u003c/p\u003e"
}
],
"value": "The Contec Co.,Ltd. CONPROSYS HMI System (CHS) exposes a PHP phpinfo() debug page to unauthenticated users that may contain sensitive data useful for an attacker.This issue affects CONPROSYS HMI System (CHS): before 3.7.7."
}
],
"impacts": [
{
"capecId": "CAPEC-37",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-37 Retrieve Embedded Sensitive Data"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-215",
"description": "CWE-215 Insertion of Sensitive Information Into Debugging Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-21T19:24:57.237Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU92266386/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/conprosys-hmi-system-exposed-php-debug-info"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "CONPROSYS HMI System (CHS) \u003c 3.7.7 Exposed PHP Debug Info",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-34081",
"datePublished": "2025-07-01T17:56:56.073Z",
"dateReserved": "2025-04-15T19:15:22.551Z",
"dateUpdated": "2025-11-21T19:24:57.237Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-34080 (GCVE-0-2025-34080)
Vulnerability from cvelistv5 – Published: 2025-07-01 17:51 – Updated: 2025-11-21 19:25
VLAI
EPSS
VEX
Title
CONPROSYS HMI System (CHS) < 3.7.7 Reflected Cross-Site Scripting
Summary
The Contec Co.,Ltd. CONPROSYS HMI System (CHS) is vulnerable to Cross-Site Scripting (XSS) in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.This issue affects CONPROSYS HMI System (CHS): before 3.7.7.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-01 18:47 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://jvn.jp/en/vu/JVNVU92266386/ | third-party-advisory |
| https://www.vulncheck.com/advisories/conprosys-hm… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co.,Ltd. | CONPROSYS HMI System (CHS) |
Affected:
0 , < 3.7.7
(semver)
cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-34080",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-01T18:47:11.611812Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-01T18:47:23.334Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"modules": [
"getqsetting.php"
],
"product": "CONPROSYS HMI System (CHS)",
"vendor": "Contec Co.,Ltd.",
"versions": [
{
"lessThan": "3.7.7",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:contec:conprosys_hmi_system:*:*:*:*:*:*:*:*",
"versionEndExcluding": "3.7.7",
"versionStartIncluding": "0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Alex Williams of Converge Technology Solutions"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The Contec Co.,Ltd. CONPROSYS HMI System (CHS) is vulnerable to Cross-Site Scripting (XSS) in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.\u003cp\u003eThis issue affects CONPROSYS HMI System (CHS): before 3.7.7.\u003c/p\u003e"
}
],
"value": "The Contec Co.,Ltd. CONPROSYS HMI System (CHS) is vulnerable to Cross-Site Scripting (XSS) in the getqsetting.php functionality that could allow reflected execution of scripts in the browser on interaction.This issue affects CONPROSYS HMI System (CHS): before 3.7.7."
}
],
"impacts": [
{
"capecId": "CAPEC-63",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-63 Cross-Site Scripting (XSS)"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-21T19:25:27.043Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU92266386/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/conprosys-hmi-system-reflected-xss"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "CONPROSYS HMI System (CHS) \u003c 3.7.7 Reflected Cross-Site Scripting",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-34080",
"datePublished": "2025-07-01T17:51:53.979Z",
"dateReserved": "2025-04-15T19:15:22.550Z",
"dateUpdated": "2025-11-21T19:25:27.043Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-46509 (GCVE-0-2023-46509)
Vulnerability from cvelistv5 – Published: 2023-10-27 00:00 – Updated: 2024-09-12 14:13
VLAI
EPSS
VEX
Summary
An issue in Contec SolarView Compact v.6.0 and before allows an attacker to execute arbitrary code via the texteditor.php component.
Severity
No CVSS data available.
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-10 14:15 UTC
CWE
- n/a
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| contec | solarview_compact |
Affected:
0 , ≤ 6.0
(custom)
cpe:2.3:h:contec:solarview_compact:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T20:45:42.270Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://gist.github.com/ATonysan/d6f72e9eb90407d64bed4566aa80afb1#file-cve-2023-46509"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:contec:solarview_compact:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "solarview_compact",
"vendor": "contec",
"versions": [
{
"lessThanOrEqual": "6.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-46509",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-10T14:15:34.861950Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-12T14:13:31.239Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue in Contec SolarView Compact v.6.0 and before allows an attacker to execute arbitrary code via the texteditor.php component."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-10-27T20:40:22.919Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://gist.github.com/ATonysan/d6f72e9eb90407d64bed4566aa80afb1#file-cve-2023-46509"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-46509",
"datePublished": "2023-10-27T00:00:00.000Z",
"dateReserved": "2023-10-23T00:00:00.000Z",
"dateUpdated": "2024-09-12T14:13:31.239Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}