FKIE_CVE-2023-2186
Vulnerability from fkie_nvd - Published: 2023-06-07 07:15 - Updated: 2026-10-23 23:10
Severity
8.2 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/
Summary
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.01.03"
}
]
}
],
"source": "trellixpsirt@trellix.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A763593D-AA02-4DF7-9D24-A88EB254594D",
"versionEndIncluding": "5.01.03",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On Triangle MicroWorks\u0027 SCADA Data Gateway version \u003c= v5.01.03, an unauthenticated attacker can send a specially crafted broadcast message including format string characters to the SCADA Data Gateway to perform unrestricted memory reads.An unauthenticated user can use this format string vulnerability to repeatedly crash the GTWWebMonitor.exe process to DoS the Web Monitor. Furthermore, an authenticated user can leverage this vulnerability to leak memory from the GTWWebMonitor.exe process. This could be leveraged in an exploit chain to gain code execution."
},
{
"lang": "es",
"value": "En la versi\u00f3n menor o igual a v5.01.03 de SCADA Data Gateway de Triangle MicroWorks, un atacante no autenticado puede enviar un mensaje de difusi\u00f3n especialmente dise\u00f1ado que incluye caracteres de cadena de formato al SCADA Data Gateway para realizar lecturas de memoria sin restricciones. Un usuario no autenticado puede usar esta vulnerabilidad de cadena de formato para bloquear repetidamente el proceso GTWWebMonitor.exe para realizar un DoS al Web Monitor. Adem\u00e1s, un usuario autenticado puede aprovechar esta vulnerabilidad para filtrar memoria del proceso GTWWebMonitor.exe. Esto podr\u00eda ser aprovechado en una cadena de exploits para obtener ejecuci\u00f3n de c\u00f3digo."
}
],
"id": "CVE-2023-2186",
"lastModified": "2026-10-23T23:10:00.157",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 4.2,
"source": "trellixpsirt@trellix.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-2186",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T20:10:12.309182Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-06-07T07:15:08.490",
"references": [
{
"source": "trellixpsirt@trellix.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.trellix.com/en-us/about/newsroom/stories/research/industrial-and-manufacturing-cves.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.trellix.com/en-us/about/newsroom/stories/research/industrial-and-manufacturing-cves.html"
}
],
"sourceIdentifier": "trellixpsirt@trellix.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-134"
}
],
"source": "trellixpsirt@trellix.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-134"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-2187
Vulnerability from fkie_nvd - Published: 2023-06-07 07:15 - Updated: 2026-10-23 23:10
Severity
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
5.3 (Medium) - CVSS:3.1/
Summary
On Triangle MicroWorks' SCADA Data Gateway version <= v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a "password change event". Furthermore, an attacker could use this vulnerability to spam the logged-in user with false events.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | * |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.01.03"
}
]
}
],
"source": "trellixpsirt@trellix.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A763593D-AA02-4DF7-9D24-A88EB254594D",
"versionEndIncluding": "5.01.03",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "On Triangle MicroWorks\u0027 SCADA Data Gateway version \u003c= v5.01.03, an unauthenticated attacker can send broadcast events to any user via the WebMonitor.An unauthenticated user can use this vulnerability to forcefully log out of any currently logged-in user by sending a \"password change event\". Furthermore, an attacker could use this vulnerability to spam the logged-in user with false events."
},
{
"lang": "es",
"value": "En la versi\u00f3n menor o igual a v5.01.03 de SCADA Data Gateway de Triangle MicroWorks, un atacante no autenticado puede enviar eventos de difusi\u00f3n a cualquier usuario a trav\u00e9s del WebMonitor. Un usuario no autenticado puede usar esta vulnerabilidad para cerrar la sesi\u00f3n forzosamente de cualquier usuario actualmente conectado enviando un \u0027evento de cambio de contrase\u00f1a\u0027. Adem\u00e1s, un atacante podr\u00eda usar esta vulnerabilidad para enviar correo no deseado al usuario conectado con eventos falsos."
}
],
"id": "CVE-2023-2187",
"lastModified": "2026-10-23T23:10:00.157",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "trellixpsirt@trellix.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-2187",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-06T21:08:33.609789Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-06-07T07:15:08.740",
"references": [
{
"source": "trellixpsirt@trellix.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.trellix.com/en-us/about/newsroom/stories/research/industrial-and-manufacturing-cves.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.trellix.com/en-us/about/newsroom/stories/research/industrial-and-manufacturing-cves.html"
}
],
"sourceIdentifier": "trellixpsirt@trellix.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "trellixpsirt@trellix.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2024-34057
Vulnerability from fkie_nvd - Published: 2024-09-18 19:15 - Updated: 2026-06-17 07:32
Severity
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
8.2 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H
8.2 (High) - CVSS:3.1/
Summary
Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://trianglemicroworks.com/products/source-code-libraries/iec-61850-scl-pages/what%27s-new | Release Notes | |
| cve@mitre.org | https://www.cisa.gov/news-events/ics-advisories/icsa-24-256-16 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | iec_61850_source_code_library | * | |
| siemens | sicam_a8000_firmware | * | |
| siemens | sicam_a8000 | - | |
| siemens | sicam_scc_firmware | * | |
| siemens | sicam_scc | - | |
| siemens | sicam_egs_firmware | * | |
| siemens | sicam_egs | - | |
| siemens | sicam_s8000 | * | |
| siemens | sitipe_at | * |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "cve@mitre.org"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:iec_61850_client_source_code_library:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "iec_61850_client_source_code_library",
"vendor": "trianglemicroworks",
"versions": [
{
"lessThan": "12.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:iec_61850_source_code_library:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C3253ACC-02E5-4AFD-AAA0-2F47E5AD3D26",
"versionEndExcluding": "12.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sicam_a8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6EA612FA-5E60-4278-A7A3-9C28E5857AD8",
"versionEndExcluding": "05.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sicam_a8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5BF612C4-56F9-4946-86E5-6D7C309E195F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sicam_scc_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1760C8BA-E26C-48BD-8733-801C5245B1D0",
"versionEndExcluding": "10.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sicam_scc:-:*:*:*:*:*:*:*",
"matchCriteriaId": "26100EEE-4859-41BD-83A8-F2D57FC3F5C1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sicam_egs_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7D8AAD69-99AA-48C7-AD40-431FC65085AC",
"versionEndExcluding": "05.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sicam_egs:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B926004A-C343-4C15-9AF4-32C1B4EEEEB2",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sicam_s8000:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48484B01-98F1-41CB-876D-5DE76E65E7B2",
"versionEndExcluding": "05.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sitipe_at:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5A83D1DC-FCF0-4E05-BF26-CFDFAC4A2513",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service."
},
{
"lang": "es",
"value": "Las librer\u00edas de c\u00f3digo fuente de Triangle Microworks TMW IEC 61850 Client anteriores a la versi\u00f3n 12.2.0 carecen de una comprobaci\u00f3n del tama\u00f1o del b\u00fafer al procesar los mensajes recibidos. El desbordamiento del b\u00fafer resultante puede provocar un bloqueo, lo que da como resultado una denegaci\u00f3n de servicio."
}
],
"id": "CVE-2024-34057",
"lastModified": "2026-06-17T07:32:49.443",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 4.2,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-34057",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-19T14:17:19.898121Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-09-18T19:15:40.777",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Release Notes"
],
"url": "https://trianglemicroworks.com/products/source-code-libraries/iec-61850-scl-pages/what%27s-new"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-256-16"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39468
Vulnerability from fkie_nvd - Published: 2024-05-03 03:15 - Updated: 2026-06-17 06:12
Severity
Summary
Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.
The specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3.20324 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
"matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo de funci\u00f3n peligrosa expuesta. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. La falla espec\u00edfica existe en el manejo del par\u00e1metro DbasSectorFileToExecuteOnReset. El problema se debe a una funci\u00f3n peligrosa expuesta. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto de SYSTEM. Era ZDI-CAN-20799."
}
],
"id": "CVE-2023-39468",
"lastModified": "2026-06-17T06:12:23.807",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39468",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T17:19:46.064913Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-03T03:15:12.563",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1036/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1036/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-749"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39467
Vulnerability from fkie_nvd - Published: 2024-05-03 03:15 - Updated: 2026-06-17 06:12
Severity
Summary
Triangle MicroWorks SCADA Data Gateway certificate Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the configuration of certificate web directory. The issue results from the exposure of sensitive information in the application webroot. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20798.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3.20324 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
"matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway certificate Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of certificate web directory. The issue results from the exposure of sensitive information in the application webroot. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20798."
},
{
"lang": "es",
"value": "Vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n del certificado SCADA Data Gateway de Triangle MicroWorks. Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial sobre las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. No se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. La falla espec\u00edfica existe en la configuraci\u00f3n del directorio web del certificado. El problema se debe a la exposici\u00f3n de informaci\u00f3n confidencial en la ra\u00edz web de la aplicaci\u00f3n. Un atacante puede aprovechar esta vulnerabilidad para revelar informaci\u00f3n confidencial. Era ZDI-CAN-20798."
}
],
"id": "CVE-2023-39467",
"lastModified": "2026-06-17T06:12:23.677",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39467",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-07T19:22:23.242020Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-03T03:15:12.360",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1035/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1035/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-219"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39466
Vulnerability from fkie_nvd - Published: 2024-05-03 03:15 - Updated: 2026-06-17 06:12
Severity
Summary
Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3.20324 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
"matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway get_config Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the get_config endpoint. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20797."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway get_config Vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n de autenticaci\u00f3n faltante. Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial sobre las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. No se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. La falla espec\u00edfica existe dentro del endpoint get_config. El problema se debe a la falta de autenticaci\u00f3n antes de permitir el acceso a la funcionalidad. Un atacante puede aprovechar esta vulnerabilidad para revelar informaci\u00f3n confidencial. Era ZDI-CAN-20797."
}
],
"id": "CVE-2023-39466",
"lastModified": "2026-06-17T06:12:23.553",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39466",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T17:12:42.172392Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-03T03:15:12.193",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1034/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1034/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39465
Vulnerability from fkie_nvd - Published: 2024-05-03 03:15 - Updated: 2026-06-17 06:12
Severity
Summary
Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the TmwCrypto class. The issue results from the usage of a hard-coded cryptograhic key and the usage of a hard-coded certificate. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20615.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3.20324 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
"matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the TmwCrypto class. The issue results from the usage of a hard-coded cryptograhic key and the usage of a hard-coded certificate. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20615."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway Uso de vulnerabilidad de divulgaci\u00f3n de informaci\u00f3n clave criptogr\u00e1fica codificada. Esta vulnerabilidad permite a atacantes remotos revelar informaci\u00f3n confidencial sobre las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. No se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. La falla espec\u00edfica existe dentro de la clase TmwCrypto. El problema se debe al uso de una clave criptogr\u00e1fica codificada y el uso de un certificado codificado. Un atacante puede aprovechar esta vulnerabilidad para revelar informaci\u00f3n confidencial. Era ZDI-CAN-20615."
}
],
"id": "CVE-2023-39465",
"lastModified": "2026-06-17T06:12:23.427",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39465",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-06T15:37:18.521094Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-03T03:15:12.030",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1033/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1033/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-321"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39464
Vulnerability from fkie_nvd - Published: 2024-05-03 03:15 - Updated: 2026-06-17 06:12
Severity
Summary
Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3.20324 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
"matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Unquoted Search Path Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the configuration of the GTWWebMonitorService service. The path to the service executable contains spaces not surrounded by quotations. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20538."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway GTWWebMonitorService Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo en ruta de b\u00fasqueda sin comillas. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Aunque se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad, se puede omitir el mecanismo de autenticaci\u00f3n existente. La falla espec\u00edfica existe en la configuraci\u00f3n del servicio GTWWebMonitorService. La ruta al ejecutable del servicio contiene espacios que no est\u00e1n entre comillas. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo arbitrario en el contexto de la ra\u00edz. Era ZDI-CAN-20538."
}
],
"id": "CVE-2023-39464",
"lastModified": "2026-06-17T06:12:23.300",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39464",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T17:13:49.483707Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-03T03:15:11.870",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1032/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1032/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-428"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39463
Vulnerability from fkie_nvd - Published: 2024-05-03 03:15 - Updated: 2026-06-17 06:12
Severity
Summary
Triangle MicroWorks SCADA Data Gateway Trusted Certification Unrestricted Upload of File Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the trusted certification feature. The issue lies in the handling of the OpcUaSecurityCertificateAuthorityTrustDir variable, which allows an arbitrary file write with attacker-controlled data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20537.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3.20324 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
"matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway Trusted Certification Unrestricted Upload of File Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the trusted certification feature. The issue lies in the handling of the OpcUaSecurityCertificateAuthorityTrustDir variable, which allows an arbitrary file write with attacker-controlled data. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20537."
},
{
"lang": "es",
"value": "Certificaci\u00f3n confiable de Triangle MicroWorks SCADA Data Gateway Carga sin restricciones de archivos Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Aunque se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad, se puede omitir el mecanismo de autenticaci\u00f3n existente. La falla espec\u00edfica existe dentro de la funci\u00f3n de certificaci\u00f3n confiable. El problema radica en el manejo de la variable OpcUaSecurityCertificateAuthorityTrustDir, que permite la escritura arbitraria de archivos con datos controlados por el atacante. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto de SYSTEM. Era ZDI-CAN-20537."
}
],
"id": "CVE-2023-39463",
"lastModified": "2026-06-17T06:12:23.177",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39463",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T17:16:15.340389Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-03T03:15:11.703",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1031/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1031/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-434"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39462
Vulnerability from fkie_nvd - Published: 2024-05-03 03:15 - Updated: 2026-06-17 06:12
Severity
Summary
Triangle MicroWorks SCADA Data Gateway Workspace Unrestricted Upload Vulnerability. This vulnerability allows remote attackers to upload arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this in conjunction with other vulnerabilitites to execute arbitrary code in the context of root. Was ZDI-CAN-20536.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3.20324 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
"matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway Workspace Unrestricted Upload Vulnerability. This vulnerability allows remote attackers to upload arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of user-supplied data, which can allow the upload of arbitrary files. An attacker can leverage this in conjunction with other vulnerabilitites to execute arbitrary code in the context of root. Was ZDI-CAN-20536."
},
{
"lang": "es",
"value": "Vulnerabilidad de carga sin restricciones del espacio de trabajo de puerta de enlace de datos SCADA de Triangle MicroWorks. Esta vulnerabilidad permite a atacantes remotos cargar archivos arbitrarios en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Aunque se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad, se puede omitir el mecanismo de autenticaci\u00f3n existente. La falla espec\u00edfica existe en el procesamiento de archivos del espacio de trabajo. El problema se debe a la falta de una validaci\u00f3n adecuada de los datos proporcionados por el usuario, lo que puede permitir la carga de archivos arbitrarios. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo arbitrario en el contexto de la ra\u00edz. Era ZDI-CAN-20536."
}
],
"id": "CVE-2023-39462",
"lastModified": "2026-06-17T06:12:23.043",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39462",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T17:16:53.971929Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-03T03:15:11.533",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1030/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1030/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-434"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39461
Vulnerability from fkie_nvd - Published: 2024-05-03 03:15 - Updated: 2026-06-17 06:12
Severity
Summary
Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability. This vulnerability allows remote attackers to write arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the handling of event logs. The issue results from improper sanitization of log output. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20535.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3.20324 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
"matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway Event Log Improper Output Neutralization For Logs Arbitrary File Write Vulnerability. This vulnerability allows remote attackers to write arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the handling of event logs. The issue results from improper sanitization of log output. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20535."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway Registro de eventos Neutralizaci\u00f3n de salida inadecuada para registros Vulnerabilidad de escritura de archivos arbitrarios. Esta vulnerabilidad permite a atacantes remotos escribir archivos arbitrarios en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Aunque se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad, se puede omitir el mecanismo de autenticaci\u00f3n existente. La falla espec\u00edfica existe en el manejo de registros de eventos. El problema se debe a una sanitizaci\u00f3n inadecuada de la salida de registros. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo en el contexto ra\u00edz. Era ZDI-CAN-20535."
}
],
"id": "CVE-2023-39461",
"lastModified": "2026-06-17T06:12:22.917",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:N",
"version": "3.0"
},
"exploitabilityScore": 0.7,
"impactScore": 3.6,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39461",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-03T19:12:41.966123Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-03T03:15:11.363",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1029/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1029/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-117"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39460
Vulnerability from fkie_nvd - Published: 2024-05-03 03:15 - Updated: 2026-06-17 06:12
Severity
Summary
Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the creation of event logs. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20534.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3.20324 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
"matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway Event Log Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the creation of event logs. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-20534."
},
{
"lang": "es",
"value": "Vulnerabilidad de creaci\u00f3n de archivos arbitrarios de recorrido de directorio de registro de eventos de puerta de enlace de datos SCADA de Triangle MicroWorks. Esta vulnerabilidad permite a atacantes remotos crear archivos arbitrarios en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Aunque se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad, se puede omitir el mecanismo de autenticaci\u00f3n existente. La falla espec\u00edfica existe en la creaci\u00f3n de registros de eventos. El problema se debe a la falta de validaci\u00f3n adecuada de una ruta proporcionada por el usuario antes de usarla en operaciones de archivos. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo en el contexto ra\u00edz. Era ZDI-CAN-20534."
}
],
"id": "CVE-2023-39460",
"lastModified": "2026-06-17T06:12:22.760",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39460",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T17:18:57.800496Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-03T03:15:11.157",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1028/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1028/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39459
Vulnerability from fkie_nvd - Published: 2024-05-03 03:15 - Updated: 2026-06-17 06:12
Severity
Summary
Triangle MicroWorks SCADA Data Gateway Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.
The specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to create files in the context of Administrator. Was ZDI-CAN-20531.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3:*:*:*:*:*:*:*",
"matchCriteriaId": "E52553E2-31EB-48D8-AB17-167CE092FB8C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to create files in the context of Administrator. Was ZDI-CAN-20531."
},
{
"lang": "es",
"value": "Vulnerabilidad de creaci\u00f3n de archivos arbitrarios Directory Traversal de puerta de enlace de datos SCADA de Triangle MicroWorks. Esta vulnerabilidad permite a atacantes remotos crear archivos arbitrarios en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Se requiere la interacci\u00f3n del usuario para aprovechar esta vulnerabilidad, ya que el objetivo debe visitar una p\u00e1gina maliciosa o abrir un archivo malicioso. La falla espec\u00edfica existe en el procesamiento de archivos del espacio de trabajo. El problema se debe a la falta de validaci\u00f3n adecuada de una ruta proporcionada por el usuario antes de usarla en operaciones de archivos. Un atacante puede aprovechar esta vulnerabilidad para crear archivos en el contexto del Administrador. Era ZDI-CAN-20531."
}
],
"id": "CVE-2023-39459",
"lastModified": "2026-06-17T06:12:22.630",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39459",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-07T19:23:56.632854Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-03T03:15:10.987",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1027/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1027/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39458
Vulnerability from fkie_nvd - Published: 2024-05-03 03:15 - Updated: 2026-06-17 06:12
Severity
Summary
Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the handling of certificates. The service uses a hard-coded default SSL certificate. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20509.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3.20324 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
"matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of certificates. The service uses a hard-coded default SSL certificate. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20509."
},
{
"lang": "es",
"value": "Vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n de credenciales codificadas mediante el uso de la puerta de enlace de datos SCADA de Triangle MicroWorks. Esta vulnerabilidad permite a atacantes adyacentes a la red eludir la autenticaci\u00f3n en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. No se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. La falla espec\u00edfica existe en el manejo de certificados. El servicio utiliza un certificado SSL predeterminado codificado. Un atacante puede aprovechar esta vulnerabilidad para eludir la autenticaci\u00f3n en el sistema. Era ZDI-CAN-20509."
}
],
"id": "CVE-2023-39458",
"lastModified": "2026-06-17T06:12:22.480",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 1.6,
"impactScore": 3.6,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39458",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T17:17:39.486576Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-03T03:15:10.823",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1026/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1026/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39457
Vulnerability from fkie_nvd - Published: 2024-05-03 03:15 - Updated: 2026-06-17 06:12
Severity
Summary
Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.
The specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.1.3.20324 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*",
"matchCriteriaId": "B3AC0B76-A64D-4650-AFF9-4B9AE5A8C4C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists due to the lack of user authentication. The issue results from missing authentication in the default system configuration. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-20501."
},
{
"lang": "es",
"value": "Vulnerabilidad de autenticaci\u00f3n faltante en la puerta de enlace de datos SCADA de Triangle MicroWorks. Esta vulnerabilidad permite a atacantes remotos evitar la autenticaci\u00f3n en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. No se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad. La falla espec\u00edfica existe debido a la falta de autenticaci\u00f3n del usuario. El problema se debe a la falta de autenticaci\u00f3n en la configuraci\u00f3n predeterminada del sistema. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo arbitrario en el contexto de la ra\u00edz. Era ZDI-CAN-20501."
}
],
"id": "CVE-2023-39457",
"lastModified": "2026-06-17T06:12:22.250",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2023-39457",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T17:18:26.342775Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-03T03:15:10.647",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1025/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1025/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-306"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-38138
Vulnerability from fkie_nvd - Published: 2022-10-11 21:15 - Updated: 2026-06-17 04:56
Severity
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/
Summary
The Triangle Microworks IEC 61850 Library (Any client or server using the C language library with a version number of 11.2.0 or earlier and any client or server using the C++, C#, or Java language library with a version number of 5.0.1 or earlier) and 60870-6 (ICCP/TASE.2) Library (Any client or server using a C++ language library with a version number of 4.4.3 or earlier) are vulnerable to access given to a small number of uninitialized pointers within their code. This could allow an attacker to target any client or server using the affected libraries to cause a denial-of-service condition.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-01 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-01 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | iec_60870-6_software_library | - | |
| trianglemicroworks | iec_61850_software_library | - |
{
"affected": [
{
"affectedData": [
{
"product": "Library: IEC 61850",
"vendor": "Triangle Microworks",
"versions": [
{
"status": "affected",
"version": "Any client or server using the C language library with a version number of 11.2.0 or earlier"
},
{
"status": "affected",
"version": "Any client or server using the C++, C#, or Java language library with a version number of 5.0.1 or earlier"
}
]
},
{
"product": "Library: IEC 60870-6 (ICCP/Tase.2)",
"vendor": "Triangle Microworks",
"versions": [
{
"status": "affected",
"version": "Any client or server using a C++ language library with a version number of 4.4.3 or earlier"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:iec_60870-6_software_library:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E96977A1-8B2A-4B3D-9E71-29B98D45C982",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:iec_61850_software_library:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EF0D9113-EBE1-47C8-9C5E-96D3A527ADA2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Triangle Microworks IEC 61850 Library (Any client or server using the C language library with a version number of 11.2.0 or earlier and any client or server using the C++, C#, or Java language library with a version number of 5.0.1 or earlier) and 60870-6 (ICCP/TASE.2) Library (Any client or server using a C++ language library with a version number of 4.4.3 or earlier) are vulnerable to access given to a small number of uninitialized pointers within their code. This could allow an attacker to target any client or server using the affected libraries to cause a denial-of-service condition."
},
{
"lang": "es",
"value": "La biblioteca IEC 61850 de Triangle Microworks (cualquier cliente o servidor que usando la biblioteca de lenguaje C con un n\u00famero de versi\u00f3n de 11.2.0 o anterior y cualquier cliente o servidor usando la biblioteca de lenguaje C++, C# o Java con un n\u00famero de versi\u00f3n de 5.0.1 o anterior) y la biblioteca 60870-6 (ICCP/TASE.2) (cualquier cliente o servidor que utilice una biblioteca de lenguaje C++ con un n\u00famero de versi\u00f3n de 4.4.3 o anterior) son vulnerables al acceso dado a un peque\u00f1o n\u00famero de punteros no inicializados dentro de su c\u00f3digo. Esto podr\u00eda permitir a un atacante dirigirse a cualquier cliente o servidor que utilice las bibliotecas afectadas para causar una condici\u00f3n de denegaci\u00f3n de servicio"
}
],
"id": "CVE-2022-38138",
"lastModified": "2026-06-17T04:56:10.410",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-38138",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:54:06.629943Z",
"version": "2.0.3"
}
}
]
},
"published": "2022-10-11T21:15:13.710",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-249-01"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-824"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-824"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-0369
Vulnerability from fkie_nvd - Published: 2024-05-07 23:15 - Updated: 2026-06-17 04:20
Severity
Summary
Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the Restore Workspace feature. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17227.
References
| URL | Tags | ||
|---|---|---|---|
| zdi-disclosures@trendmicro.com | https://www.zerodayinitiative.com/advisories/ZDI-23-450/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-23-450/ | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | 5.01.01 |
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.01.01"
}
]
}
],
"source": "zdi-disclosures@trendmicro.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.01.01:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.01.01"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.01.01:*:*:*:*:*:*:*",
"matchCriteriaId": "AF3E967D-A1E2-455A-8E64-3E797D31E964",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the Restore Workspace feature. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17227."
},
{
"lang": "es",
"value": "Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo Directory Traversal de espacio de trabajo de restauraci\u00f3n de puerta de enlace de datos SCADA de Triangle MicroWorks. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Aunque se requiere autenticaci\u00f3n para aprovechar esta vulnerabilidad, se puede omitir el mecanismo de autenticaci\u00f3n existente. La falla espec\u00edfica existe dentro de la funci\u00f3n Restaurar espacio de trabajo. El problema se debe a la falta de validaci\u00f3n adecuada de una ruta proporcionada por el usuario antes de usarla en operaciones de archivos. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto de SYSTEM. Era ZDI-CAN-17227."
}
],
"id": "CVE-2022-0369",
"lastModified": "2026-06-17T04:20:28.537",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-0369",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T17:07:32.283678Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-05-07T23:15:14.490",
"references": [
{
"source": "zdi-disclosures@trendmicro.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-450/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-450/"
}
],
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "zdi-disclosures@trendmicro.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2020-6996
Vulnerability from fkie_nvd - Published: 2020-04-15 19:15 - Updated: 2026-06-17 03:24
Severity
Summary
Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.us-cert.gov/ics/advisories/icsa-20-105-02 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-20-105-02 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | dnp3_source_code_library | * |
{
"affected": [
{
"affectedData": [
{
"product": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:dnp3_source_code_library:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6F97C26A-1C2B-4616-9DB1-109946BB64FF",
"versionEndIncluding": "3.25.01",
"versionStartIncluding": "3.16.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks DNP3 Outstation LibrariesDNP3 Outstation .NET Protocol components and DNP3 Outstation ANSI C source code libraries are affected:3.16.00 through 3.25.01. A specially crafted message may cause a stack-based buffer overflow. Authentication is not required to exploit this vulnerability."
},
{
"lang": "es",
"value": "Librer\u00edas de Triangle MicroWorks DNP3 Outstation Los componentes del Protocolo .NET Outstation DNP3 y las bibliotecas de c\u00f3digo fuente ANSI C de DNP3 Outstation se ven afectadas: 3.16.00 a 3.25.01. Un mensaje especialmente dise\u00f1ado puede causar un desbordamiento del b\u00fafer basado en la pila. No se requiere autenticaci\u00f3n para explotar esta vulnerabilidad."
}
],
"id": "CVE-2020-6996",
"lastModified": "2026-06-17T03:24:05.537",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-15T19:15:13.927",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-02"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-10615
Vulnerability from fkie_nvd - Published: 2020-04-15 19:15 - Updated: 2026-06-17 02:48
Severity
Summary
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.us-cert.gov/ics/advisories/icsa-20-105-03 | Third Party Advisory, US Government Resource | |
| ics-cert@hq.dhs.gov | https://www.zerodayinitiative.com/advisories/ZDI-20-547/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-20-105-03 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-20-547/ | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | * |
{
"affected": [
{
"affectedData": [
{
"product": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3F22582F-32D4-4E3A-AF76-CDB180CC0D03",
"versionEndIncluding": "4.0.122",
"versionStartIncluding": "2.41.0213",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway versiones 3.02.0697 hasta 4.0.122, versiones 2.41.0213 hasta 4.0.122, permite a atacantes remotos causar una condici\u00f3n de denegaci\u00f3n de servicio debido a la falta de una comprobaci\u00f3n apropiada de la longitud de datos suministrados por el usuario, antes de copiar en un b\u00fafer en la regi\u00f3n stack de la memoria de longitud fija. No es requerida una autenticaci\u00f3n para explotar esta vulnerabilidad."
}
],
"id": "CVE-2020-10615",
"lastModified": "2026-06-17T02:48:06.250",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-15T19:15:13.753",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-03"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-20-547/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-20-547/"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-10613
Vulnerability from fkie_nvd - Published: 2020-04-15 19:15 - Updated: 2026-06-17 02:48
Severity
Summary
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.us-cert.gov/ics/advisories/icsa-20-105-03 | Third Party Advisory, US Government Resource | |
| ics-cert@hq.dhs.gov | https://www.zerodayinitiative.com/advisories/ZDI-20-548/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-20-105-03 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-20-548/ | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | * |
{
"affected": [
{
"affectedData": [
{
"product": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3F22582F-32D4-4E3A-AF76-CDB180CC0D03",
"versionEndIncluding": "4.0.122",
"versionStartIncluding": "2.41.0213",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway versiones 3.02.0697 hasta 4.0.122, versiones 2.41.0213 hasta 4.0.122, permite a atacantes remotos divulgar informaci\u00f3n confidencial debido a la falta de comprobaci\u00f3n apropiada de los datos suministrados por el usuario, lo que puede resultar en una lectura m\u00e1s all\u00e1 del final de una estructura asignada. No es requerida una autenticaci\u00f3n para explotar esta vulnerabilidad. Solo aplicable a instalaciones que utilizan DNP3 Data Sets."
}
],
"id": "CVE-2020-10613",
"lastModified": "2026-06-17T02:48:06.033",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-15T19:15:13.690",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-03"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-20-548/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-20-548/"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-10611
Vulnerability from fkie_nvd - Published: 2020-04-15 19:15 - Updated: 2026-06-17 02:48
Severity
Summary
Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.
References
| URL | Tags | ||
|---|---|---|---|
| ics-cert@hq.dhs.gov | https://www.us-cert.gov/ics/advisories/icsa-20-105-03 | Third Party Advisory, US Government Resource | |
| ics-cert@hq.dhs.gov | https://www.zerodayinitiative.com/advisories/ZDI-20-549/ | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-20-105-03 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.zerodayinitiative.com/advisories/ZDI-20-549/ | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | scada_data_gateway | * |
{
"affected": [
{
"affectedData": [
{
"product": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3F22582F-32D4-4E3A-AF76-CDB180CC0D03",
"versionEndIncluding": "4.0.122",
"versionStartIncluding": "2.41.0213",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway versiones 3.02.0697 hasta 4.0.122, versiones 2.41.0213 hasta 4.0.122, permite a atacantes remotos ejecutar c\u00f3digo arbitrario debido a la falta de comprobaci\u00f3n apropiada de los datos suministrados por el usuario, lo que puede causar una condici\u00f3n de confusi\u00f3n de tipos. No es requerida una autenticaci\u00f3n para explotar esta vulnerabilidad. Solo aplicable a instalaciones que utilizan DNP3 Data Sets."
}
],
"id": "CVE-2020-10611",
"lastModified": "2026-06-17T02:48:05.810",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-15T19:15:13.613",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-03"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-20-549/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-20-549/"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-843"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-843"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2014-2343
Vulnerability from fkie_nvd - Published: 2014-05-30 23:55 - Updated: 2026-06-17 00:06
Severity
Summary
Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows physically proximate attackers to cause a denial of service (excessive data processing) via a crafted DNP request over a serial line.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"lessThan": "v3.00.0635",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A505671F-8C57-47A2-89D4-DC6186F5D7DA",
"versionEndIncluding": "3.00.0633",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50:*:*:*:*:*:*:*",
"matchCriteriaId": "D2626C47-B68A-4A21-B5A2-9D64A28A7120",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50.0309:*:*:*:*:*:*:*",
"matchCriteriaId": "69D2B52D-B324-4115-A3BB-51E3BF97758B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.51:*:*:*:*:*:*:*",
"matchCriteriaId": "9406C4EC-5758-458D-8354-6736CA78A660",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.53:*:*:*:*:*:*:*",
"matchCriteriaId": "EB915370-216E-40DC-AEF5-634230394E00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0515:*:*:*:*:*:*:*",
"matchCriteriaId": "22E5498C-D5F0-43F7-A536-AB65B4DEB49F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0516:*:*:*:*:*:*:*",
"matchCriteriaId": "2099DFC5-F241-4C47-9A17-FE40101A4570",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0517:*:*:*:*:*:*:*",
"matchCriteriaId": "F1E898A9-7F0E-453C-8509-75E7E1290382",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0518:*:*:*:*:*:*:*",
"matchCriteriaId": "E513983A-C6A2-4E07-874B-880F7A013D53",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0528:*:*:*:*:*:*:*",
"matchCriteriaId": "D6861F70-5798-4B41-BE94-BECCF16752BB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0529:*:*:*:*:*:*:*",
"matchCriteriaId": "1B5722CA-130A-46B3-9A30-9661069890AF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0536:*:*:*:*:*:*:*",
"matchCriteriaId": "F5E625A4-30E4-4D5B-81B2-B0B0569948DB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0540:*:*:*:*:*:*:*",
"matchCriteriaId": "5A6D03B5-2E8C-49E9-8A18-F367F72A4D50",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0544:*:*:*:*:*:*:*",
"matchCriteriaId": "AF59F8E0-C4BA-4658-9B91-BACD59B9C482",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0545:*:*:*:*:*:*:*",
"matchCriteriaId": "BD36BB8A-C840-494B-835C-98EB0075CA62",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0552:*:*:*:*:*:*:*",
"matchCriteriaId": "8FDB5301-887B-4950-A918-113B75D2BDE5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0553:*:*:*:*:*:*:*",
"matchCriteriaId": "76BF9332-5F3E-4230-A742-2019B2DCEB22",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0558:*:*:*:*:*:*:*",
"matchCriteriaId": "1610F5AE-3BB1-4BDB-8C88-A2B83DBE39C1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0561:*:*:*:*:*:*:*",
"matchCriteriaId": "1E2A4B7A-D8DA-4A1E-8506-A2D377E7568D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0562:*:*:*:*:*:*:*",
"matchCriteriaId": "90EA0A71-B4C7-4F54-A439-4B0FA9637410",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0564:*:*:*:*:*:*:*",
"matchCriteriaId": "71B02213-096E-4CA2-8528-64E83EA06D27",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0565:*:*:*:*:*:*:*",
"matchCriteriaId": "8EA1B917-A27E-4043-BD74-534B13916F3B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0566:*:*:*:*:*:*:*",
"matchCriteriaId": "378C61EE-9420-42D3-9DA2-71F2D459ACE9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0567:*:*:*:*:*:*:*",
"matchCriteriaId": "CA21BE3B-6C2E-4479-A9A0-E3966741B832",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0569:*:*:*:*:*:*:*",
"matchCriteriaId": "49C97936-8AF3-41D8-8D6B-F6C9C5F4B002",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0570:*:*:*:*:*:*:*",
"matchCriteriaId": "D3175298-E0A4-4571-BDCC-FDA81675BC67",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0571:*:*:*:*:*:*:*",
"matchCriteriaId": "18BF8DF0-93D1-4ACA-BA78-B6DE0080AD52",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0572:*:*:*:*:*:*:*",
"matchCriteriaId": "E1D5F9B2-38C5-45AC-9A33-80E61BAF0E17",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0573:*:*:*:*:*:*:*",
"matchCriteriaId": "00666362-AD62-4942-96E8-C08BF087E34F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0574:*:*:*:*:*:*:*",
"matchCriteriaId": "5BC82C89-7D15-452D-8610-23F3952487E9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0575:*:*:*:*:*:*:*",
"matchCriteriaId": "3D15DD91-4F01-4B95-8F9A-C4848800BDBB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0576:*:*:*:*:*:*:*",
"matchCriteriaId": "9DF57506-CC34-473C-8165-CB26194E80BB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0577:*:*:*:*:*:*:*",
"matchCriteriaId": "CC480C77-1950-4C3A-B77E-D2C2AC59FE20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0578:*:*:*:*:*:*:*",
"matchCriteriaId": "2044B8C6-D0C6-4A1E-9798-19912FFAE097",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0579:*:*:*:*:*:*:*",
"matchCriteriaId": "40D4B1C5-CE06-4082-9534-513BB99D7D7B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0580:*:*:*:*:*:*:*",
"matchCriteriaId": "15E62697-E6BD-4796-9470-F6E125CD3F4C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0581:*:*:*:*:*:*:*",
"matchCriteriaId": "299D658E-143A-4556-A6FF-37EDA07828CF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0582:*:*:*:*:*:*:*",
"matchCriteriaId": "7619010A-954E-4F5D-8DDB-0ED652E2A306",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0583:*:*:*:*:*:*:*",
"matchCriteriaId": "C042A0EB-AB96-4FD2-A19E-4E9101C2C63C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0584:*:*:*:*:*:*:*",
"matchCriteriaId": "B8B7B997-4D7F-4A34-822A-3AF52A4FA715",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0586:*:*:*:*:*:*:*",
"matchCriteriaId": "3E073D1B-4FBF-4DE2-AA5A-1EE8774D20FD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0587:*:*:*:*:*:*:*",
"matchCriteriaId": "2285B98B-3E80-4C5B-9D7D-DA7C250FBAD0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0588:*:*:*:*:*:*:*",
"matchCriteriaId": "0EC58901-067E-485B-9723-9F344F306C39",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0589:*:*:*:*:*:*:*",
"matchCriteriaId": "E4583789-CC14-48BB-83B5-AF1B6896B10B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0590:*:*:*:*:*:*:*",
"matchCriteriaId": "7CEC3409-0CED-41A8-8718-B0EFCA85DA49",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0591:*:*:*:*:*:*:*",
"matchCriteriaId": "B4AEB67C-7DAF-44D2-BB32-FD9E86D8EA0A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0592:*:*:*:*:*:*:*",
"matchCriteriaId": "383DA8F4-1DDD-43A9-8A53-721F5F449CA2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0594:*:*:*:*:*:*:*",
"matchCriteriaId": "1AD95D30-4502-44EB-9C0C-D9A45CD24E5C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0595:*:*:*:*:*:*:*",
"matchCriteriaId": "B9F60297-9FA4-47F6-98AF-B9662568D76F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0596:*:*:*:*:*:*:*",
"matchCriteriaId": "4E593FD2-7158-40D0-9F44-01C06BF96F06",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0597:*:*:*:*:*:*:*",
"matchCriteriaId": "0D8A435F-8C6D-4584-8DB9-4A0C515F6D3B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0598:*:*:*:*:*:*:*",
"matchCriteriaId": "5F210B77-F989-4931-AFBF-CEC2A175FC27",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0599:*:*:*:*:*:*:*",
"matchCriteriaId": "36BBE6AE-BEE1-441B-A5A4-30BD7FCFBF3B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00:*:*:*:*:*:*:*",
"matchCriteriaId": "F74C4546-500F-405C-B585-6F6C07065808",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0612:*:*:*:*:*:*:*",
"matchCriteriaId": "948521F4-CA30-4269-8A98-96F9AD004150",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0615:*:*:*:*:*:*:*",
"matchCriteriaId": "9D9853CB-38CC-419D-A9F8-EDDA2F6CE4F8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0616:*:*:*:*:*:*:*",
"matchCriteriaId": "7C679459-44C7-454C-9894-87ABE1F710F2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0630:*:*:*:*:*:*:*",
"matchCriteriaId": "CD169173-9189-42BE-A741-955889E44FC9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows physically proximate attackers to cause a denial of service (excessive data processing) via a crafted DNP request over a serial line."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway anterior a 3.00.0635 permite a atacantes f\u00edsicamente pr\u00f3ximos causar una denegaci\u00f3n de servicio (procesamiento de datos excesivo) a trav\u00e9s de una solicitud DNP manipulada sobre una l\u00ednea de serie."
}
],
"id": "CVE-2014-2343",
"lastModified": "2026-06-17T00:06:26.867",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "HIGH",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 1.2,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:H/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 1.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"userInteractionRequired": false
},
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 2.1,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2014-05-30T23:55:02.783",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"url": "http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-149-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"US Government Resource"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2014-2342
Vulnerability from fkie_nvd - Published: 2014-05-30 23:55 - Updated: 2026-06-17 00:06
Severity
Summary
Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service (excessive data processing) via a crafted DNP3 packet.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"lessThan": "v3.00.0635",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A505671F-8C57-47A2-89D4-DC6186F5D7DA",
"versionEndIncluding": "3.00.0633",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50:*:*:*:*:*:*:*",
"matchCriteriaId": "D2626C47-B68A-4A21-B5A2-9D64A28A7120",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50.0309:*:*:*:*:*:*:*",
"matchCriteriaId": "69D2B52D-B324-4115-A3BB-51E3BF97758B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.51:*:*:*:*:*:*:*",
"matchCriteriaId": "9406C4EC-5758-458D-8354-6736CA78A660",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.53:*:*:*:*:*:*:*",
"matchCriteriaId": "EB915370-216E-40DC-AEF5-634230394E00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0515:*:*:*:*:*:*:*",
"matchCriteriaId": "22E5498C-D5F0-43F7-A536-AB65B4DEB49F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0516:*:*:*:*:*:*:*",
"matchCriteriaId": "2099DFC5-F241-4C47-9A17-FE40101A4570",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0517:*:*:*:*:*:*:*",
"matchCriteriaId": "F1E898A9-7F0E-453C-8509-75E7E1290382",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0518:*:*:*:*:*:*:*",
"matchCriteriaId": "E513983A-C6A2-4E07-874B-880F7A013D53",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0528:*:*:*:*:*:*:*",
"matchCriteriaId": "D6861F70-5798-4B41-BE94-BECCF16752BB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0529:*:*:*:*:*:*:*",
"matchCriteriaId": "1B5722CA-130A-46B3-9A30-9661069890AF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0536:*:*:*:*:*:*:*",
"matchCriteriaId": "F5E625A4-30E4-4D5B-81B2-B0B0569948DB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0540:*:*:*:*:*:*:*",
"matchCriteriaId": "5A6D03B5-2E8C-49E9-8A18-F367F72A4D50",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0544:*:*:*:*:*:*:*",
"matchCriteriaId": "AF59F8E0-C4BA-4658-9B91-BACD59B9C482",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0545:*:*:*:*:*:*:*",
"matchCriteriaId": "BD36BB8A-C840-494B-835C-98EB0075CA62",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0552:*:*:*:*:*:*:*",
"matchCriteriaId": "8FDB5301-887B-4950-A918-113B75D2BDE5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0553:*:*:*:*:*:*:*",
"matchCriteriaId": "76BF9332-5F3E-4230-A742-2019B2DCEB22",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0558:*:*:*:*:*:*:*",
"matchCriteriaId": "1610F5AE-3BB1-4BDB-8C88-A2B83DBE39C1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0561:*:*:*:*:*:*:*",
"matchCriteriaId": "1E2A4B7A-D8DA-4A1E-8506-A2D377E7568D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0562:*:*:*:*:*:*:*",
"matchCriteriaId": "90EA0A71-B4C7-4F54-A439-4B0FA9637410",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0564:*:*:*:*:*:*:*",
"matchCriteriaId": "71B02213-096E-4CA2-8528-64E83EA06D27",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0565:*:*:*:*:*:*:*",
"matchCriteriaId": "8EA1B917-A27E-4043-BD74-534B13916F3B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0566:*:*:*:*:*:*:*",
"matchCriteriaId": "378C61EE-9420-42D3-9DA2-71F2D459ACE9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0567:*:*:*:*:*:*:*",
"matchCriteriaId": "CA21BE3B-6C2E-4479-A9A0-E3966741B832",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0569:*:*:*:*:*:*:*",
"matchCriteriaId": "49C97936-8AF3-41D8-8D6B-F6C9C5F4B002",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0570:*:*:*:*:*:*:*",
"matchCriteriaId": "D3175298-E0A4-4571-BDCC-FDA81675BC67",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0571:*:*:*:*:*:*:*",
"matchCriteriaId": "18BF8DF0-93D1-4ACA-BA78-B6DE0080AD52",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0572:*:*:*:*:*:*:*",
"matchCriteriaId": "E1D5F9B2-38C5-45AC-9A33-80E61BAF0E17",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0573:*:*:*:*:*:*:*",
"matchCriteriaId": "00666362-AD62-4942-96E8-C08BF087E34F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0574:*:*:*:*:*:*:*",
"matchCriteriaId": "5BC82C89-7D15-452D-8610-23F3952487E9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0575:*:*:*:*:*:*:*",
"matchCriteriaId": "3D15DD91-4F01-4B95-8F9A-C4848800BDBB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0576:*:*:*:*:*:*:*",
"matchCriteriaId": "9DF57506-CC34-473C-8165-CB26194E80BB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0577:*:*:*:*:*:*:*",
"matchCriteriaId": "CC480C77-1950-4C3A-B77E-D2C2AC59FE20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0578:*:*:*:*:*:*:*",
"matchCriteriaId": "2044B8C6-D0C6-4A1E-9798-19912FFAE097",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0579:*:*:*:*:*:*:*",
"matchCriteriaId": "40D4B1C5-CE06-4082-9534-513BB99D7D7B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0580:*:*:*:*:*:*:*",
"matchCriteriaId": "15E62697-E6BD-4796-9470-F6E125CD3F4C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0581:*:*:*:*:*:*:*",
"matchCriteriaId": "299D658E-143A-4556-A6FF-37EDA07828CF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0582:*:*:*:*:*:*:*",
"matchCriteriaId": "7619010A-954E-4F5D-8DDB-0ED652E2A306",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0583:*:*:*:*:*:*:*",
"matchCriteriaId": "C042A0EB-AB96-4FD2-A19E-4E9101C2C63C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0584:*:*:*:*:*:*:*",
"matchCriteriaId": "B8B7B997-4D7F-4A34-822A-3AF52A4FA715",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0586:*:*:*:*:*:*:*",
"matchCriteriaId": "3E073D1B-4FBF-4DE2-AA5A-1EE8774D20FD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0587:*:*:*:*:*:*:*",
"matchCriteriaId": "2285B98B-3E80-4C5B-9D7D-DA7C250FBAD0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0588:*:*:*:*:*:*:*",
"matchCriteriaId": "0EC58901-067E-485B-9723-9F344F306C39",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0589:*:*:*:*:*:*:*",
"matchCriteriaId": "E4583789-CC14-48BB-83B5-AF1B6896B10B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0590:*:*:*:*:*:*:*",
"matchCriteriaId": "7CEC3409-0CED-41A8-8718-B0EFCA85DA49",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0591:*:*:*:*:*:*:*",
"matchCriteriaId": "B4AEB67C-7DAF-44D2-BB32-FD9E86D8EA0A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0592:*:*:*:*:*:*:*",
"matchCriteriaId": "383DA8F4-1DDD-43A9-8A53-721F5F449CA2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0594:*:*:*:*:*:*:*",
"matchCriteriaId": "1AD95D30-4502-44EB-9C0C-D9A45CD24E5C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0595:*:*:*:*:*:*:*",
"matchCriteriaId": "B9F60297-9FA4-47F6-98AF-B9662568D76F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0596:*:*:*:*:*:*:*",
"matchCriteriaId": "4E593FD2-7158-40D0-9F44-01C06BF96F06",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0597:*:*:*:*:*:*:*",
"matchCriteriaId": "0D8A435F-8C6D-4584-8DB9-4A0C515F6D3B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0598:*:*:*:*:*:*:*",
"matchCriteriaId": "5F210B77-F989-4931-AFBF-CEC2A175FC27",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0599:*:*:*:*:*:*:*",
"matchCriteriaId": "36BBE6AE-BEE1-441B-A5A4-30BD7FCFBF3B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00:*:*:*:*:*:*:*",
"matchCriteriaId": "F74C4546-500F-405C-B585-6F6C07065808",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0612:*:*:*:*:*:*:*",
"matchCriteriaId": "948521F4-CA30-4269-8A98-96F9AD004150",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0615:*:*:*:*:*:*:*",
"matchCriteriaId": "9D9853CB-38CC-419D-A9F8-EDDA2F6CE4F8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0616:*:*:*:*:*:*:*",
"matchCriteriaId": "7C679459-44C7-454C-9894-87ABE1F710F2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0630:*:*:*:*:*:*:*",
"matchCriteriaId": "CD169173-9189-42BE-A741-955889E44FC9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway before 3.00.0635 allows remote attackers to cause a denial of service (excessive data processing) via a crafted DNP3 packet."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway anterior a 3.00.0635 permite a atacantes remotos causar una denegaci\u00f3n de servicio (procesamiento de datos excesivo) a trav\u00e9s de una paquete DNP3 manipulado."
}
],
"id": "CVE-2014-2342",
"lastModified": "2026-06-17T00:06:26.737",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary",
"userInteractionRequired": false
},
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2014-05-30T23:55:02.707",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"url": "http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-149-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"US Government Resource"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-149-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.trianglemicroworks.com/products/scada-data-gateway/what%27s-new"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2013-2794
Vulnerability from fkie_nvd - Published: 2013-09-09 11:39 - Updated: 2026-06-16 23:53
Severity
Summary
Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line.
References
Impacted products
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:ansi_c_source_code_libraries:3.06.0000:*:*:*:*:*:*:*",
"matchCriteriaId": "7DECC05A-BB49-47AD-841A-0D16582C3BD0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:ansi_c_source_code_libraries:3.07.0000:*:*:*:*:*:*:*",
"matchCriteriaId": "7CA92BB5-FEAC-4270-8FC4-65476D8258DF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:ansi_c_source_code_libraries:3.08.0000:*:*:*:*:*:*:*",
"matchCriteriaId": "BB3A505C-89E2-4F5A-AC61-E036ABFC3322",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:ansi_c_source_code_libraries:3.09.0000:*:*:*:*:*:*:*",
"matchCriteriaId": "228B39FA-7B51-4AEE-986A-BD0AA3BA2FA6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:ansi_c_source_code_libraries:3.10.0000:*:*:*:*:*:*:*",
"matchCriteriaId": "EA47CA21-A500-4B38-B103-58E224A39734",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:ansi_c_source_code_libraries:3.11.0000:*:*:*:*:*:*:*",
"matchCriteriaId": "C10643AE-4541-41DB-8ECF-D4CFD482628B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:ansi_c_source_code_libraries:3.12.0000:*:*:*:*:*:*:*",
"matchCriteriaId": "9A0824BE-769F-439F-A8DC-97F6EBCB81E1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:ansi_c_source_code_libraries:3.13.0000:*:*:*:*:*:*:*",
"matchCriteriaId": "93B33FC8-D566-4BC8-97E2-3584BA9AC987",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:ansi_c_source_code_libraries:3.14.0000:*:*:*:*:*:*:*",
"matchCriteriaId": "DFFE40C1-8E33-4295-A0E0-2FA1F5BAF9C6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:ansi_c_source_code_libraries:3.15.0000:*:*:*:*:*:*:*",
"matchCriteriaId": "AEB98E06-B56D-4168-A94C-8D7FCBA58FEF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:.net_communication_protocol_components:3.06.0.171:*:*:*:*:*:*:*",
"matchCriteriaId": "FFDA2B53-1513-4DDF-B325-025FEFA5E16B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:.net_communication_protocol_components:3.07.00:*:*:*:*:*:*:*",
"matchCriteriaId": "12E48EA6-095F-49E5-B65E-A780C25C8FCE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:.net_communication_protocol_components:3.08.00:*:*:*:*:*:*:*",
"matchCriteriaId": "7D7B6492-A0B9-4D68-B39C-D4246A190638",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:.net_communication_protocol_components:3.09.00:*:*:*:*:*:*:*",
"matchCriteriaId": "E240AFBC-0AF6-4406-B726-2DD7B1CE10AC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:.net_communication_protocol_components:3.10.00:*:*:*:*:*:*:*",
"matchCriteriaId": "13026105-3803-44D8-A224-4BA454917231",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:.net_communication_protocol_components:3.11.00:*:*:*:*:*:*:*",
"matchCriteriaId": "6DB5DBE4-796A-4D17-8805-7DB725CCFB4D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:.net_communication_protocol_components:3.14.00:*:*:*:*:*:*:*",
"matchCriteriaId": "F1F5CDC3-ECE6-486D-AFB1-C570825202DB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:.net_communication_protocol_components:3.15.00:*:*:*:*:*:*:*",
"matchCriteriaId": "FDF26C3C-1E7B-4243-A5FF-CD80CCCA2FCC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:.net_communication_protocol_components:3.15.0.369:*:*:*:*:*:*:*",
"matchCriteriaId": "045F45E6-DB41-4D65-968B-CD04596004D0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50:*:*:*:*:*:*:*",
"matchCriteriaId": "D2626C47-B68A-4A21-B5A2-9D64A28A7120",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50.0309:*:*:*:*:*:*:*",
"matchCriteriaId": "69D2B52D-B324-4115-A3BB-51E3BF97758B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.51:*:*:*:*:*:*:*",
"matchCriteriaId": "9406C4EC-5758-458D-8354-6736CA78A660",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.53:*:*:*:*:*:*:*",
"matchCriteriaId": "EB915370-216E-40DC-AEF5-634230394E00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0515:*:*:*:*:*:*:*",
"matchCriteriaId": "22E5498C-D5F0-43F7-A536-AB65B4DEB49F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0516:*:*:*:*:*:*:*",
"matchCriteriaId": "2099DFC5-F241-4C47-9A17-FE40101A4570",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0517:*:*:*:*:*:*:*",
"matchCriteriaId": "F1E898A9-7F0E-453C-8509-75E7E1290382",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0518:*:*:*:*:*:*:*",
"matchCriteriaId": "E513983A-C6A2-4E07-874B-880F7A013D53",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0528:*:*:*:*:*:*:*",
"matchCriteriaId": "D6861F70-5798-4B41-BE94-BECCF16752BB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0529:*:*:*:*:*:*:*",
"matchCriteriaId": "1B5722CA-130A-46B3-9A30-9661069890AF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0536:*:*:*:*:*:*:*",
"matchCriteriaId": "F5E625A4-30E4-4D5B-81B2-B0B0569948DB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0540:*:*:*:*:*:*:*",
"matchCriteriaId": "5A6D03B5-2E8C-49E9-8A18-F367F72A4D50",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0544:*:*:*:*:*:*:*",
"matchCriteriaId": "AF59F8E0-C4BA-4658-9B91-BACD59B9C482",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0545:*:*:*:*:*:*:*",
"matchCriteriaId": "BD36BB8A-C840-494B-835C-98EB0075CA62",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0552:*:*:*:*:*:*:*",
"matchCriteriaId": "8FDB5301-887B-4950-A918-113B75D2BDE5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0553:*:*:*:*:*:*:*",
"matchCriteriaId": "76BF9332-5F3E-4230-A742-2019B2DCEB22",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0558:*:*:*:*:*:*:*",
"matchCriteriaId": "1610F5AE-3BB1-4BDB-8C88-A2B83DBE39C1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0561:*:*:*:*:*:*:*",
"matchCriteriaId": "1E2A4B7A-D8DA-4A1E-8506-A2D377E7568D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0562:*:*:*:*:*:*:*",
"matchCriteriaId": "90EA0A71-B4C7-4F54-A439-4B0FA9637410",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0564:*:*:*:*:*:*:*",
"matchCriteriaId": "71B02213-096E-4CA2-8528-64E83EA06D27",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0565:*:*:*:*:*:*:*",
"matchCriteriaId": "8EA1B917-A27E-4043-BD74-534B13916F3B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0566:*:*:*:*:*:*:*",
"matchCriteriaId": "378C61EE-9420-42D3-9DA2-71F2D459ACE9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0567:*:*:*:*:*:*:*",
"matchCriteriaId": "CA21BE3B-6C2E-4479-A9A0-E3966741B832",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0569:*:*:*:*:*:*:*",
"matchCriteriaId": "49C97936-8AF3-41D8-8D6B-F6C9C5F4B002",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0570:*:*:*:*:*:*:*",
"matchCriteriaId": "D3175298-E0A4-4571-BDCC-FDA81675BC67",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0571:*:*:*:*:*:*:*",
"matchCriteriaId": "18BF8DF0-93D1-4ACA-BA78-B6DE0080AD52",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0572:*:*:*:*:*:*:*",
"matchCriteriaId": "E1D5F9B2-38C5-45AC-9A33-80E61BAF0E17",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0573:*:*:*:*:*:*:*",
"matchCriteriaId": "00666362-AD62-4942-96E8-C08BF087E34F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0574:*:*:*:*:*:*:*",
"matchCriteriaId": "5BC82C89-7D15-452D-8610-23F3952487E9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0575:*:*:*:*:*:*:*",
"matchCriteriaId": "3D15DD91-4F01-4B95-8F9A-C4848800BDBB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0576:*:*:*:*:*:*:*",
"matchCriteriaId": "9DF57506-CC34-473C-8165-CB26194E80BB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0577:*:*:*:*:*:*:*",
"matchCriteriaId": "CC480C77-1950-4C3A-B77E-D2C2AC59FE20",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0578:*:*:*:*:*:*:*",
"matchCriteriaId": "2044B8C6-D0C6-4A1E-9798-19912FFAE097",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0579:*:*:*:*:*:*:*",
"matchCriteriaId": "40D4B1C5-CE06-4082-9534-513BB99D7D7B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0580:*:*:*:*:*:*:*",
"matchCriteriaId": "15E62697-E6BD-4796-9470-F6E125CD3F4C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0581:*:*:*:*:*:*:*",
"matchCriteriaId": "299D658E-143A-4556-A6FF-37EDA07828CF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0582:*:*:*:*:*:*:*",
"matchCriteriaId": "7619010A-954E-4F5D-8DDB-0ED652E2A306",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0583:*:*:*:*:*:*:*",
"matchCriteriaId": "C042A0EB-AB96-4FD2-A19E-4E9101C2C63C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0584:*:*:*:*:*:*:*",
"matchCriteriaId": "B8B7B997-4D7F-4A34-822A-3AF52A4FA715",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0586:*:*:*:*:*:*:*",
"matchCriteriaId": "3E073D1B-4FBF-4DE2-AA5A-1EE8774D20FD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0587:*:*:*:*:*:*:*",
"matchCriteriaId": "2285B98B-3E80-4C5B-9D7D-DA7C250FBAD0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0588:*:*:*:*:*:*:*",
"matchCriteriaId": "0EC58901-067E-485B-9723-9F344F306C39",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0589:*:*:*:*:*:*:*",
"matchCriteriaId": "E4583789-CC14-48BB-83B5-AF1B6896B10B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0590:*:*:*:*:*:*:*",
"matchCriteriaId": "7CEC3409-0CED-41A8-8718-B0EFCA85DA49",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0591:*:*:*:*:*:*:*",
"matchCriteriaId": "B4AEB67C-7DAF-44D2-BB32-FD9E86D8EA0A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0592:*:*:*:*:*:*:*",
"matchCriteriaId": "383DA8F4-1DDD-43A9-8A53-721F5F449CA2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0594:*:*:*:*:*:*:*",
"matchCriteriaId": "1AD95D30-4502-44EB-9C0C-D9A45CD24E5C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0595:*:*:*:*:*:*:*",
"matchCriteriaId": "B9F60297-9FA4-47F6-98AF-B9662568D76F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0596:*:*:*:*:*:*:*",
"matchCriteriaId": "4E593FD2-7158-40D0-9F44-01C06BF96F06",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0597:*:*:*:*:*:*:*",
"matchCriteriaId": "0D8A435F-8C6D-4584-8DB9-4A0C515F6D3B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0598:*:*:*:*:*:*:*",
"matchCriteriaId": "5F210B77-F989-4931-AFBF-CEC2A175FC27",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.54.0599:*:*:*:*:*:*:*",
"matchCriteriaId": "36BBE6AE-BEE1-441B-A5A4-30BD7FCFBF3B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00:*:*:*:*:*:*:*",
"matchCriteriaId": "F74C4546-500F-405C-B585-6F6C07065808",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0616:*:*:*:*:*:*:*",
"matchCriteriaId": "7C679459-44C7-454C-9894-87ABE1F710F2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway 2.50.0309 hasta 3.00.0616, Componentes de protocolo DNP3 .NET 3.06.0.171 hasta 3.15.0.369, y librer\u00edas C DNP3 3.06.0000 hasta 3.15.0000 permiten a un atacante con acceso f\u00edsico causar una denegaci\u00f3n de servicio (bucle infinito) a trav\u00e9s de una entrada manipulada a trav\u00e9s de puerto serie."
}
],
"id": "CVE-2013-2794",
"lastModified": "2026-06-16T23:53:58.817",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 4.9,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2013-09-09T11:39:08.443",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"US Government Resource"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-240-01"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "http://www.trianglemicroworks.com/documents/mdnp_scl_whats_new.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"US Government Resource"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-240-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.trianglemicroworks.com/documents/mdnp_scl_whats_new.pdf"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2013-2793
Vulnerability from fkie_nvd - Published: 2013-09-09 11:39 - Updated: 2026-06-16 23:53
Severity
Summary
Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | .net_communication_protocol_components | 3.06.0.171 | |
| trianglemicroworks | .net_communication_protocol_components | 3.15.0.369 | |
| trianglemicroworks | ansi_c_source_code_libraries | 3.06.0000 | |
| trianglemicroworks | ansi_c_source_code_libraries | 3.15.0000 | |
| trianglemicroworks | scada_data_gateway | 2.50 | |
| trianglemicroworks | scada_data_gateway | 2.50.0309 | |
| trianglemicroworks | scada_data_gateway | 3.00.0616 |
{
"affected": [
{
"affectedData": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"source": "ics-cert@hq.dhs.gov"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:trianglemicroworks:.net_communication_protocol_components:3.06.0.171:*:*:*:*:*:*:*",
"matchCriteriaId": "FFDA2B53-1513-4DDF-B325-025FEFA5E16B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:.net_communication_protocol_components:3.15.0.369:*:*:*:*:*:*:*",
"matchCriteriaId": "045F45E6-DB41-4D65-968B-CD04596004D0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:ansi_c_source_code_libraries:3.06.0000:*:*:*:*:*:*:*",
"matchCriteriaId": "7DECC05A-BB49-47AD-841A-0D16582C3BD0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:ansi_c_source_code_libraries:3.15.0000:*:*:*:*:*:*:*",
"matchCriteriaId": "AEB98E06-B56D-4168-A94C-8D7FCBA58FEF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50:*:*:*:*:*:*:*",
"matchCriteriaId": "D2626C47-B68A-4A21-B5A2-9D64A28A7120",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:2.50.0309:*:*:*:*:*:*:*",
"matchCriteriaId": "69D2B52D-B324-4115-A3BB-51E3BF97758B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:trianglemicroworks:scada_data_gateway:3.00.0616:*:*:*:*:*:*:*",
"matchCriteriaId": "7C679459-44C7-454C-9894-87ABE1F710F2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet."
},
{
"lang": "es",
"value": "Triangle MicroWorks SCADA Data Gateway 2.50.0309 hasta 3.00.0616 , Componentes de Protocolo DNP3 .NET 3.06.0.171 hasta 3.15.0.369 y Librer\u00edas C DNP3 3.06.0000 hasta 3.15.0000 permiten a un atacante remoto causar una denegaci\u00f3n de servicio (bucle infinito) a trav\u00e9s de un paquete TCP DNP3 manipulado."
}
],
"id": "CVE-2013-2793",
"lastModified": "2026-06-16T23:53:58.720",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2013-09-09T11:39:08.427",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"US Government Resource"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-240-01"
},
{
"source": "ics-cert@hq.dhs.gov",
"url": "http://www.trianglemicroworks.com/documents/mdnp_scl_whats_new.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"US Government Resource"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-240-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.trianglemicroworks.com/documents/mdnp_scl_whats_new.pdf"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2024-34057 (GCVE-0-2024-34057)
Vulnerability from nvd – Published: 2024-09-18 00:00 – Updated: 2024-09-19 14:21
VLAI
EPSS
VEX
Summary
Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service.
Severity
8.2 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-19 14:17 UTC
CWE
- n/a
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | iec_61850_client_source_code_library |
Affected:
0 , < 12.2.0
(custom)
cpe:2.3:a:trianglemicroworks:iec_61850_client_source_code_library:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:iec_61850_client_source_code_library:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "iec_61850_client_source_code_library",
"vendor": "trianglemicroworks",
"versions": [
{
"lessThan": "12.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-34057",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-19T14:17:19.898121Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-19T14:21:28.567Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-18T18:54:44.376Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://trianglemicroworks.com/products/source-code-libraries/iec-61850-scl-pages/what%27s-new"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-256-16"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-34057",
"datePublished": "2024-09-18T00:00:00.000Z",
"dateReserved": "2024-04-30T00:00:00.000Z",
"dateUpdated": "2024-09-19T14:21:28.567Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-0369 (GCVE-0-2022-0369)
Vulnerability from nvd – Published: 2024-05-07 22:54 – Updated: 2024-08-02 23:25
VLAI
EPSS
VEX
Title
Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability
Summary
Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the Restore Workspace feature. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17227.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-08 17:07 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Triangle MicroWorks | SCADA Data Gateway |
Affected:
5.01.01
|
|
| trianglemicroworks | scada_data_gateway |
Affected:
5.01.01
cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.01.01:*:*:*:*:*:*:* |
Date Public
2023-04-14 19:00
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.01.01:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.01.01"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-0369",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T17:07:32.283678Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-23T17:09:35.862Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T23:25:40.264Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-450",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-450/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.01.01"
}
]
}
],
"dateAssigned": "2022-01-25T22:23:37.257Z",
"datePublic": "2023-04-14T19:00:47.542Z",
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the Restore Workspace feature. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17227."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T22:54:55.247Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-450",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-450/"
}
],
"source": {
"lang": "en",
"value": "Steven Seeley (mr_me) and Chris Anastasio (muffin) of Incite Team"
},
"title": "Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2022-0369",
"datePublished": "2024-05-07T22:54:55.247Z",
"dateReserved": "2022-01-25T22:22:48.663Z",
"dateUpdated": "2024-08-02T23:25:40.264Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39468 (GCVE-0-2023-39468)
Vulnerability from nvd – Published: 2024-05-03 01:59 – Updated: 2024-08-02 18:10
VLAI
EPSS
VEX
Title
Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability
Summary
Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.
The specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-08 17:19 UTC
CWE
- CWE-749 - Exposed Dangerous Method or Function
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| https://www.trianglemicroworks.com/products/scada… | vendor-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Triangle MicroWorks | SCADA Data Gateway |
Affected:
5.1.3.20324
|
|
| trianglemicroworks | scada_data_gateway |
Affected:
5.1.3.20324
cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:* |
Date Public
2023-08-04 18:44
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3.20324:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39468",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T17:19:46.064913Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:27:09.598Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:10:20.697Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-1036",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1036/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.1.3.20324"
}
]
}
],
"dateAssigned": "2023-08-02T21:44:31.433Z",
"datePublic": "2023-08-04T18:44:48.544Z",
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is required to exploit this vulnerability.\n\nThe specific flaw exists within the handling of DbasSectorFileToExecuteOnReset parameter. The issue results from an exposed dangerous function. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-20799."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-749",
"description": "CWE-749: Exposed Dangerous Method or Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-03T01:59:30.325Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-1036",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1036/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://www.trianglemicroworks.com/products/scada-data-gateway/what\u0027s-new"
}
],
"source": {
"lang": "en",
"value": "Uri Katz of Claroty Team82"
},
"title": "Triangle MicroWorks SCADA Data Gateway DbasSectorFileToExecuteOnReset Exposed Dangerous Function Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2023-39468",
"datePublished": "2024-05-03T01:59:30.325Z",
"dateReserved": "2023-08-02T21:37:23.123Z",
"dateUpdated": "2024-08-02T18:10:20.697Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-34057 (GCVE-0-2024-34057)
Vulnerability from cvelistv5 – Published: 2024-09-18 00:00 – Updated: 2024-09-19 14:21
VLAI
EPSS
VEX
Summary
Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service.
Severity
8.2 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-09-19 14:17 UTC
CWE
- n/a
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| trianglemicroworks | iec_61850_client_source_code_library |
Affected:
0 , < 12.2.0
(custom)
cpe:2.3:a:trianglemicroworks:iec_61850_client_source_code_library:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:iec_61850_client_source_code_library:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "iec_61850_client_source_code_library",
"vendor": "trianglemicroworks",
"versions": [
{
"lessThan": "12.2.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-34057",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-19T14:17:19.898121Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-19T14:21:28.567Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Triangle Microworks TMW IEC 61850 Client source code libraries before 12.2.0 lack a buffer size check when processing received messages. The resulting buffer overflow can cause a crash, resulting in a denial of service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-18T18:54:44.376Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://trianglemicroworks.com/products/source-code-libraries/iec-61850-scl-pages/what%27s-new"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-256-16"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-34057",
"datePublished": "2024-09-18T00:00:00.000Z",
"dateReserved": "2024-04-30T00:00:00.000Z",
"dateUpdated": "2024-09-19T14:21:28.567Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-0369 (GCVE-0-2022-0369)
Vulnerability from cvelistv5 – Published: 2024-05-07 22:54 – Updated: 2024-08-02 23:25
VLAI
EPSS
VEX
Title
Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability
Summary
Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.
The specific flaw exists within the Restore Workspace feature. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17227.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-05-08 17:07 UTC
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Triangle MicroWorks | SCADA Data Gateway |
Affected:
5.01.01
|
|
| trianglemicroworks | scada_data_gateway |
Affected:
5.01.01
cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.01.01:*:*:*:*:*:*:* |
Date Public
2023-04-14 19:00
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.01.01:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "scada_data_gateway",
"vendor": "trianglemicroworks",
"versions": [
{
"status": "affected",
"version": "5.01.01"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-0369",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-08T17:07:32.283678Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-23T17:09:35.862Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T23:25:40.264Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-23-450",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-450/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SCADA Data Gateway",
"vendor": "Triangle MicroWorks",
"versions": [
{
"status": "affected",
"version": "5.01.01"
}
]
}
],
"dateAssigned": "2022-01-25T22:23:37.257Z",
"datePublic": "2023-04-14T19:00:47.542Z",
"descriptions": [
{
"lang": "en",
"value": "Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Triangle MicroWorks SCADA Data Gateway. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the Restore Workspace feature. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of SYSTEM. Was ZDI-CAN-17227."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-07T22:54:55.247Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-23-450",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-23-450/"
}
],
"source": {
"lang": "en",
"value": "Steven Seeley (mr_me) and Chris Anastasio (muffin) of Incite Team"
},
"title": "Triangle MicroWorks SCADA Data Gateway Restore Workspace Directory Traversal Remote Code Execution Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2022-0369",
"datePublished": "2024-05-07T22:54:55.247Z",
"dateReserved": "2022-01-25T22:22:48.663Z",
"dateUpdated": "2024-08-02T23:25:40.264Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}