CVE-2022-31801 (GCVE-0-2022-31801)
Vulnerability from cvelistv5 – Published: 2022-06-21 08:00 – Updated: 2026-06-02 20:16- CWE-345 - Insufficient Verification of Data Authenticity
| URL | Tags |
|---|---|
| https://cert.vde.com/en/advisories/VDE-2022-026/ | x_refsource_CONFIRM |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| PHOENIX CONTACT | MULTIPROG |
Affected:
All Versions
|
guessed | |
| PHOENIX CONTACT | ProConOS |
Affected:
All Versions
|
guessed | |
| PHOENIX CONTACT | ProConOS eCLR |
Affected:
All Versions
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-026/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-31801",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T19:55:07.271340Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T20:16:11.339Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "MULTIPROG",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"product": "ProConOS",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"product": "ProConOS eCLR",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This vulnerability was reported by Forescout."
}
],
"datePublic": "2022-06-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-21T08:00:31.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-026/"
}
],
"source": {
"advisory": "VDE-2022-026",
"discovery": "EXTERNAL"
},
"title": "Insufficient Verification of Data Vulnerability in ProConOS/ProConOS eCLR SDK and MULTIPROG Engineering tool",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2022-06-21T07:00:00.000Z",
"ID": "CVE-2022-31801",
"STATE": "PUBLIC",
"TITLE": "Insufficient Verification of Data Vulnerability in ProConOS/ProConOS eCLR SDK and MULTIPROG Engineering tool"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MULTIPROG",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "All Versions",
"version_value": "All Versions"
}
]
}
},
{
"product_name": "ProConOS",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "All Versions",
"version_value": "All Versions"
}
]
}
},
{
"product_name": "ProConOS eCLR",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "All Versions",
"version_value": "All Versions"
}
]
}
}
]
},
"vendor_name": "PHOENIX CONTACT"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "This vulnerability was reported by Forescout."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-345 Insufficient Verification of Data Authenticity"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2022-026/",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2022-026/"
}
]
},
"source": {
"advisory": "VDE-2022-026",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-31801",
"datePublished": "2022-06-21T08:00:31.688Z",
"dateReserved": "2022-05-30T00:00:00.000Z",
"dateUpdated": "2026-06-02T20:16:11.339Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-31801",
"date": "2026-11-28",
"epss": "0.01123",
"percentile": "0.65953"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenixcontact:multiprog:*:*:*:*:*:*:*:*",
"matchCriteriaId": "42452860-CB53-479D-ADE1-E8166EC834C4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:phoenixcontact:proconos:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80770720-B149-44CA-B6CA-25EB8C9A115C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:phoenixcontact-software:proconos_eclr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4CDFE3B8-1A42-4E5E-92BD-5F1B07EF0377",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device."
},
{
"lang": "es",
"value": "Un atacante remoto no autenticado podr\u00eda cargar l\u00f3gica maliciosa en los dispositivos basados en ProConOS/ProConOS eCLR para conseguir el control total del dispositivo"
}
],
"id": "CVE-2022-31801",
"lastModified": "2024-11-21T07:05:21.537",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
},
"published": "2022-06-21T08:15:07.587",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-026/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-026/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-345"
}
],
"source": "info@cert.vde.com",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"product": "MULTIPROG",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"product": "ProConOS",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"product": "ProConOS eCLR",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"source": "info@cert.vde.com"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:phoenixcontact:multiprog:*:*:*:*:*:*:*:*",
"matchCriteriaId": "42452860-CB53-479D-ADE1-E8166EC834C4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:phoenixcontact:proconos:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80770720-B149-44CA-B6CA-25EB8C9A115C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:phoenixcontact-software:proconos_eclr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4CDFE3B8-1A42-4E5E-92BD-5F1B07EF0377",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device."
},
{
"lang": "es",
"value": "Un atacante remoto no autenticado podr\u00eda cargar l\u00f3gica maliciosa en los dispositivos basados en ProConOS/ProConOS eCLR para conseguir el control total del dispositivo"
}
],
"id": "CVE-2022-31801",
"lastModified": "2026-06-17T04:46:20.110",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "info@cert.vde.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-31801",
"options": [
{
"exploitation": "none"
},
{
"automatable": "yes"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T19:55:07.271340Z",
"version": "2.0.3"
}
}
]
},
"published": "2022-06-21T08:15:07.587",
"references": [
{
"source": "info@cert.vde.com",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-026/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-026/"
}
],
"sourceIdentifier": "info@cert.vde.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-345"
}
],
"source": "info@cert.vde.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2026-03-27T12:21:57+00:00",
"cve": "CVE-2022-31801",
"id": "CVE-2022-31801",
"initial_release_date": "2022-06-21T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "Insufficient Verification of Data Vulnerability in ProConOS/ProConOS eCLR SDK and MULTIPROG Engineering tool",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-31801.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:26:01.136Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-026/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-31801",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T19:55:07.271340Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T19:54:59.405Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "MULTIPROG",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"product": "ProConOS",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"product": "ProConOS eCLR",
"vendor": "PHOENIX CONTACT",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This vulnerability was reported by Forescout."
}
],
"datePublic": "2022-06-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-21T08:00:31.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en/advisories/VDE-2022-026/"
}
],
"source": {
"advisory": "VDE-2022-026",
"discovery": "EXTERNAL"
},
"title": "Insufficient Verification of Data Vulnerability in ProConOS/ProConOS eCLR SDK and MULTIPROG Engineering tool",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2022-06-21T07:00:00.000Z",
"ID": "CVE-2022-31801",
"STATE": "PUBLIC",
"TITLE": "Insufficient Verification of Data Vulnerability in ProConOS/ProConOS eCLR SDK and MULTIPROG Engineering tool"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MULTIPROG",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "All Versions",
"version_value": "All Versions"
}
]
}
},
{
"product_name": "ProConOS",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "All Versions",
"version_value": "All Versions"
}
]
}
},
{
"product_name": "ProConOS eCLR",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "All Versions",
"version_value": "All Versions"
}
]
}
}
]
},
"vendor_name": "PHOENIX CONTACT"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "This vulnerability was reported by Forescout."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An unauthenticated, remote attacker could upload malicious logic to the devices based on ProConOS/ProConOS eCLR in order to gain full control over the device."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-345 Insufficient Verification of Data Authenticity"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2022-026/",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2022-026/"
}
]
},
"source": {
"advisory": "VDE-2022-026",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2022-31801",
"datePublished": "2022-06-21T08:00:31.688Z",
"dateReserved": "2022-05-30T00:00:00.000Z",
"dateUpdated": "2026-06-02T20:16:11.339Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.