SSA-045512
Vulnerability from csaf_siemens - Published: 2026-10-30 00:00 - Updated: 2026-11-18 00:00A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
Integrated PA Suite Tester
Siemens / Integrated PA Suite Tester
|
vers:all/* |
Vendor Fix
|
|
|
SENTRON Powermanager V8
Siemens / SENTRON Powermanager V8
|
vers:all/* |
Vendor Fix
|
|
|
SENTRON Powermanager V9
Siemens / SENTRON Powermanager V9
|
vers:all/* |
Vendor Fix
|
|
|
SICAM PAS CC >= V6.02
Siemens / SICAM PAS CC
|
vers:intdot/>=6.02 |
Mitigation
No Fix Planned
|
|
|
SICAM SCC >= V7.01
Siemens / SICAM SCC
|
vers:intdot/>=7.01 |
Mitigation
No Fix Planned
|
|
|
Desigo CC family V8
Siemens / Desigo CC family V8
|
vers:all/* |
Vendor Fix
|
|
|
Desigo CC family V9
Siemens / Desigo CC family V9
|
vers:all/* |
Vendor Fix
|
|
|
Gridscale X DSA >= V5.3 < V5.4
Siemens / Gridscale X DSA
|
vers:intdot/>=5.3|<5.4 |
Vendor Fix
|
|
|
Gridscale X PSS®E < V36.8.0
Siemens / Gridscale X PSS®E
|
vers:intdot/<36.8.0 |
Vendor Fix
|
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
blueplanet 100 NX3 M8
Siemens / blueplanet 100 NX3 M8
|
vers:all/* | ||
|
Heliox Dual Port 60kW
Siemens / Heliox Dual Port 60kW
|
vers:all/* | ||
|
Heliox Flex Pro
Siemens / Heliox Flex Pro
|
vers:all/* | ||
|
SICHARGE FLEX
Siemens / SICHARGE FLEX
|
vers:all/* | ||
|
SICHARGE UC
Siemens / SICHARGE UC
|
vers:all/* | ||
|
Sifinity Go
Siemens / Sifinity Go
|
vers:all/* | ||
|
blueplanet 125 NX3 M10
Siemens / blueplanet 125 NX3 M10
|
vers:all/* | ||
|
Sifinity Setup
Siemens / Sifinity Setup
|
vers:all/* | ||
|
VersiCharge AC Series
Siemens / VersiCharge AC Series
|
vers:all/* | ||
|
VersiCloud
Siemens / VersiCloud
|
vers:all/* | ||
|
blueplanet 87.0 TL3 – 165 TL3 (GEN1 / GEN2)
Siemens / blueplanet 87.0 TL3 – 165 TL3 (GEN1 / GEN2)
|
vers:all/* | ||
|
blueplanet gridsave 100 – 165 TL3 (HV)
Siemens / blueplanet gridsave 100 – 165 TL3 (HV)
|
vers:all/* | ||
|
blueplanet gridsave 92 – 137 TL3 (GEN1 / GEN2)
Siemens / blueplanet gridsave 92 – 137 TL3 (GEN1 / GEN2)
|
vers:all/* |
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "On October 21, 2026, the Node.js project released security updates addressing a critical vulnerability in the Brotli decoder bundled with Node.js, commonly referred to as \"Node2Shell\" (tracked as CVE-2026-111497). The vulnerability is an out-of-bounds write that could allow a remote attacker to cause memory corruption and potentially execute arbitrary code. This advisory covers the status of impact of various Siemens software products.\n\nSiemens has released new versions for some of the affected products and recommends to update to the latest versions.",
"title": "Summary"
},
{
"category": "general",
"text": "Operators of critical power systems (e.g. TSOs or DSOs) worldwide are usually required by regulations to build resilience into the power grids by applying multi-level redundant secondary protection schemes. It is therefore recommended that the operators check whether appropriate resilient protection measures are in place. The risk of cyber incidents impacting the grid\u0027s reliability can thus be minimized by virtue of the grid design.\nSiemens strongly recommends applying the provided security updates using the corresponding tooling and documented procedures made available with the product. If supported by the product, an automated means to apply the security updates across multiple product instances may be used. Siemens strongly recommends prior validation of any security update before being applied, and supervision by trained staff of the update process in the target environment. \nAs a general security measure Siemens strongly recommends to protect network access with appropriate mechanisms (e.g. firewalls, segmentation, VPN). It is advised to configure the environment according to our operational guidelines in order to run the devices in a protected IT environment.\n\nRecommended security guidelines can be found at:\nhttps://www.siemens.com/gridsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-045512: Node2Shell Vulnerability in Siemens Products - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
},
{
"category": "self",
"summary": "SSA-045512: Node2Shell Vulnerability in Siemens Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-045512.json"
}
],
"title": "SSA-045512: Node2Shell Vulnerability in Siemens Products",
"tracking": {
"current_release_date": "2026-11-18T00:00:00.000Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-045512",
"initial_release_date": "2026-10-30T00:00:00.000Z",
"revision_history": [
{
"date": "2026-10-30T00:00:00.000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2026-11-04T00:00:00.000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added Desigo CC to the affected products list."
},
{
"date": "2026-11-06T00:00:00.000Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added Gridscale X DSA and PSSE to the list of affected products"
},
{
"date": "2026-11-18T00:00:00.000Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added SENTRON Powermanager V8 and V9, SICAM PAS CC, SICAM SCC, and IPAS Tester to the list of affected products. Added blueplanet 100 NX3 / 125 NX3, blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2), blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2), and blueplanet gridsave 100 \u2013 165 TL3 (HV) to the list of known not affected products."
}
],
"status": "interim",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "blueplanet 100 NX3 M8",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "blueplanet 100 NX3 M8"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "blueplanet 125 NX3 M10",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "blueplanet 125 NX3 M10"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "blueplanet 87.0 TL3 \u2013 165 TL3 (GEN1 / GEN2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "blueplanet gridsave 100 \u2013 165 TL3 (HV)",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "blueplanet gridsave 100 \u2013 165 TL3 (HV)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "blueplanet gridsave 92 \u2013 137 TL3 (GEN1 / GEN2)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo CC family V8",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "Desigo CC family V8"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Desigo CC family V9",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "Desigo CC family V9"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=5.3|\u003c5.4",
"product": {
"name": "Gridscale X DSA \u003e= V5.3 \u003c V5.4",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "Gridscale X DSA"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c36.8.0",
"product": {
"name": "Gridscale X PSS\u00aeE \u003c V36.8.0",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "Gridscale X PSS\u00aeE"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Heliox Dual Port 60kW",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "Heliox Dual Port 60kW"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Heliox Flex Pro",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "Heliox Flex Pro"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Integrated PA Suite Tester",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "Integrated PA Suite Tester"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SENTRON Powermanager V8",
"product_id": "13"
}
}
],
"category": "product_name",
"name": "SENTRON Powermanager V8"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SENTRON Powermanager V9",
"product_id": "14"
}
}
],
"category": "product_name",
"name": "SENTRON Powermanager V9"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=6.02",
"product": {
"name": "SICAM PAS CC \u003e= V6.02",
"product_id": "15"
}
}
],
"category": "product_name",
"name": "SICAM PAS CC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003e=7.01",
"product": {
"name": "SICAM SCC \u003e= V7.01",
"product_id": "16"
}
}
],
"category": "product_name",
"name": "SICAM SCC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICHARGE FLEX",
"product_id": "17"
}
}
],
"category": "product_name",
"name": "SICHARGE FLEX"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SICHARGE UC",
"product_id": "18"
}
}
],
"category": "product_name",
"name": "SICHARGE UC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Sifinity Go",
"product_id": "19"
}
}
],
"category": "product_name",
"name": "Sifinity Go"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "Sifinity Setup",
"product_id": "20"
}
}
],
"category": "product_name",
"name": "Sifinity Setup"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "VersiCharge AC Series",
"product_id": "21"
}
}
],
"category": "product_name",
"name": "VersiCharge AC Series"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "VersiCloud",
"product_id": "22"
}
}
],
"category": "product_name",
"name": "VersiCloud"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2026-111497",
"cwe": {
"id": "CWE-787",
"name": "Out-of-bounds Write"
},
"flags": [
{
"label": "vulnerable_code_cannot_be_controlled_by_adversary",
"product_ids": [
"3",
"5",
"1",
"4",
"2"
]
},
{
"label": "component_not_present",
"product_ids": [
"17",
"22",
"21",
"10",
"19",
"20",
"18",
"11"
]
}
],
"notes": [
{
"category": "description",
"text": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"12",
"13",
"14",
"15",
"16",
"6",
"7",
"8",
"9"
],
"known_not_affected": [
"1",
"10",
"11",
"17",
"18",
"19",
"2",
"20",
"21",
"22",
"3",
"4",
"5"
]
},
"remediations": [
{
"category": "mitigation",
"details": "Temporarily disable Brotli compression and decompression at the application or proxy layer if it is not strictly required.",
"product_ids": [
"15",
"16"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"15",
"16"
]
},
{
"category": "vendor_fix",
"details": "Update to V36.8.0 or later version",
"product_ids": [
"9"
]
},
{
"category": "vendor_fix",
"details": "Update to V5.4 or later version",
"product_ids": [
"8"
]
},
{
"category": "vendor_fix",
"details": "Install the latest .NET security updates via Windows Update.",
"product_ids": [
"12",
"13",
"14",
"6",
"7"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"12",
"13",
"14",
"15",
"16",
"6",
"7",
"8",
"9"
]
}
],
"threats": [
{
"category": "impact",
"details": "No external or user-controlled input reaches the vulnerable function.",
"product_ids": [
"3",
"5",
"1",
"4",
"2"
]
},
{
"category": "impact",
"details": "Node.js not present",
"product_ids": [
"17",
"22",
"21",
"10",
"19",
"20",
"18",
"11"
]
}
],
"title": "CVE-2026-111497"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.