SSA-273799
Vulnerability from csaf_siemens - Published: 2019-12-10 00:00 - Updated: 2022-04-12 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC CP 1626
Siemens / SIMATIC CP 1626
|
6GK1162-6AA01
|
vers:all/* |
No Fix Planned
|
|
SIMATIC HMI Panel (incl. SIPLUS variants)
Siemens / SIMATIC HMI Panel (incl. SIPLUS variants)
|
vers:all/* |
No Fix Planned
|
|
|
SIMATIC NET PC Software V14
Siemens / SIMATIC NET PC Software V14
|
< V14 SP1 Update 14 |
Vendor Fix
fix
|
|
|
SIMATIC NET PC Software V15
Siemens / SIMATIC NET PC Software V15
|
vers:all/* |
No Fix Planned
|
|
|
SIMATIC STEP 7 (TIA Portal)
Siemens / SIMATIC STEP 7 (TIA Portal)
|
< V16 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC (TIA Portal)
Siemens / SIMATIC WinCC (TIA Portal)
|
< V16 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC OA
Siemens / SIMATIC WinCC OA
|
< V3.16 P013 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC Runtime Advanced
Siemens / SIMATIC WinCC Runtime Advanced
|
< V16 |
Vendor Fix
fix
|
|
|
SIMATIC WinCC Runtime Professional
Siemens / SIMATIC WinCC Runtime Professional
|
< V16 |
Vendor Fix
fix
|
|
|
TIM 1531 IRC (incl. SIPLUS NET variants)
Siemens / TIM 1531 IRC (incl. SIPLUS NET variants)
|
< V2.1 |
Vendor Fix
fix
|
{
"document": {
"acknowledgments": [
{
"names": [
"Eli Biham",
"Sara Bitan",
"Aviad Carmel",
"Alon Dankner"
],
"organization": "Faculty of Computer Science, Technion Haifa",
"summary": "reporting the vulnerabilities"
},
{
"names": [
"Avishai Wool",
"Uriel Malin"
],
"organization": "School of Electrical Engineering, Tel-Aviv University",
"summary": "reporting the vulnerabilities"
}
],
"category": "Siemens Security Advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "A message integrity protection bypass vulnerability has been identified in several SIMATIC products. The vulnerability could allow an attacker in a Man-in-the-Middle position to modify network traffic exchanged on port 102/tcp to PLCs of the SIMATIC S7-1200, SIMATIC S7-1500 and SIMATIC SoftwareController CPU families.\n\nSiemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for products where updates are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-273799: Message Integrity Protection Bypass Vulnerability in SIMATIC Products - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
},
{
"category": "self",
"summary": "SSA-273799: Message Integrity Protection Bypass Vulnerability in SIMATIC Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-273799.txt"
},
{
"category": "self",
"summary": "SSA-273799: Message Integrity Protection Bypass Vulnerability in SIMATIC Products - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-273799.json"
}
],
"title": "SSA-273799: Message Integrity Protection Bypass Vulnerability in SIMATIC Products",
"tracking": {
"current_release_date": "2022-04-12T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-273799",
"initial_release_date": "2019-12-10T00:00:00Z",
"revision_history": [
{
"date": "2019-12-10T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2020-02-11T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added solution for TIM 1531 IRC and SIMATIC NET PC Software"
},
{
"date": "2020-03-10T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added links for WinCC Runtime"
},
{
"date": "2022-04-12T00:00:00Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added solution for SIMATIC NET PC Software V14 and clarified affected versions; Clarified no remediation planned"
}
],
"status": "final",
"version": "4"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC CP 1626",
"product_id": "1",
"product_identification_helper": {
"model_numbers": [
"6GK1162-6AA01"
]
}
}
}
],
"category": "product_name",
"name": "SIMATIC CP 1626"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC HMI Panel (incl. SIPLUS variants)",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SIMATIC HMI Panel (incl. SIPLUS variants)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V14 SP1 Update 14",
"product": {
"name": "SIMATIC NET PC Software V14",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SIMATIC NET PC Software V14"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC NET PC Software V15",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SIMATIC NET PC Software V15"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V16",
"product": {
"name": "SIMATIC STEP 7 (TIA Portal)",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SIMATIC STEP 7 (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V16",
"product": {
"name": "SIMATIC WinCC (TIA Portal)",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V3.16 P013",
"product": {
"name": "SIMATIC WinCC OA",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC OA"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V16",
"product": {
"name": "SIMATIC WinCC Runtime Advanced",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Advanced"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V16",
"product": {
"name": "SIMATIC WinCC Runtime Professional",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Professional"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V2.1",
"product": {
"name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "TIM 1531 IRC (incl. SIPLUS NET variants)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2019-10929",
"cwe": {
"id": "CWE-327",
"name": "Use of a Broken or Risky Cryptographic Algorithm"
},
"notes": [
{
"category": "summary",
"text": "Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection.\n\nThis could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10"
]
},
"references": [
{
"summary": "CVE-2019-10929 - SIMATIC NET PC Software V14",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109807351/"
},
{
"summary": "CVE-2019-10929 - SIMATIC STEP 7 (TIA Portal)",
"url": "https://support.industry.siemens.com/cs/document/109772803/"
},
{
"summary": "CVE-2019-10929 - SIMATIC WinCC (TIA Portal)",
"url": "https://support.industry.siemens.com/cs/document/109772803/"
},
{
"summary": "CVE-2019-10929 - SIMATIC WinCC OA",
"url": "https://www.winccoa.com/downloads/category/versions-patches.html"
},
{
"summary": "CVE-2019-10929 - SIMATIC WinCC Runtime Advanced",
"url": "https://support.industry.siemens.com/cs/document/109771219/"
},
{
"summary": "CVE-2019-10929 - SIMATIC WinCC Runtime Professional",
"url": "https://support.industry.siemens.com/cs/document/109771219/"
},
{
"summary": "CVE-2019-10929 - TIM 1531 IRC (incl. SIPLUS NET variants)",
"url": "https://support.industry.siemens.com/cs/document/109774204/"
},
{
"summary": "CVE-2019-10929 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2019-10929.json"
}
],
"remediations": [
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2",
"4"
]
},
{
"category": "vendor_fix",
"details": "Update to V14 SP1 Update 14 or later version",
"product_ids": [
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109807351/"
},
{
"category": "vendor_fix",
"details": "Update to version V16",
"product_ids": [
"5",
"6"
],
"url": "https://support.industry.siemens.com/cs/document/109772803/"
},
{
"category": "vendor_fix",
"details": "Update to V3.16 P013 or later version",
"product_ids": [
"7"
],
"url": "https://www.winccoa.com/downloads/category/versions-patches.html"
},
{
"category": "vendor_fix",
"details": "Update to version V16",
"product_ids": [
"8",
"9"
],
"url": "https://support.industry.siemens.com/cs/document/109771219/"
},
{
"category": "vendor_fix",
"details": "Update to V2.1",
"product_ids": [
"10"
],
"url": "https://support.industry.siemens.com/cs/document/109774204/"
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 3.7,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N/E:U/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10"
]
}
],
"title": "CVE-2019-10929"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.