SSA-348629
Vulnerability from csaf_siemens - Published: 2018-03-27 00:00 - Updated: 2022-04-12 00:00| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
OpenPCS 7 V7.1 and earlier
Siemens / OpenPCS 7 V7.1 and earlier
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
|
OpenPCS 7 V8.0
Siemens / OpenPCS 7 V8.0
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
|
OpenPCS 7 V8.1
Siemens / OpenPCS 7 V8.1
|
< V8.1 Upd5 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
OpenPCS 7 V8.2
Siemens / OpenPCS 7 V8.2
|
vers:all/* |
Vendor Fix
Mitigation
Mitigation
|
|
|
OpenPCS 7 V9.0
Siemens / OpenPCS 7 V9.0
|
< V9.0 Upd1 |
Vendor Fix
Mitigation
Mitigation
|
|
|
SIMATIC BATCH V7.1 and earlier
Siemens / SIMATIC BATCH V7.1 and earlier
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
|
SIMATIC BATCH V8.0
Siemens / SIMATIC BATCH V8.0
|
< V8.0 SP1 Upd21 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
SIMATIC BATCH V8.1
Siemens / SIMATIC BATCH V8.1
|
< V8.1 SP1 Upd16 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
SIMATIC BATCH V8.2
Siemens / SIMATIC BATCH V8.2
|
< V8.2 Upd10 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
SIMATIC BATCH V9.0
Siemens / SIMATIC BATCH V9.0
|
< V9.0 SP1 |
Vendor Fix
Mitigation
Mitigation
|
|
|
SIMATIC NET PC Software V14
Siemens / SIMATIC NET PC Software V14
|
< V14 SP1 Update 14 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
SIMATIC NET PC Software V15
Siemens / SIMATIC NET PC Software V15
|
< 15 SP1 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
SIMATIC PCS 7 V7.1 and earlier
Siemens / SIMATIC PCS 7 V7.1 and earlier
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
|
SIMATIC PCS 7 V8.0
Siemens / SIMATIC PCS 7 V8.0
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
|
SIMATIC PCS 7 V8.1
Siemens / SIMATIC PCS 7 V8.1
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
|
SIMATIC PCS 7 V8.2
Siemens / SIMATIC PCS 7 V8.2
|
< V8.2 SP1 |
Vendor Fix
Mitigation
Mitigation
|
|
|
SIMATIC PCS 7 V9.0
Siemens / SIMATIC PCS 7 V9.0
|
< V9.0 SP1 |
Vendor Fix
Mitigation
Mitigation
|
|
|
SIMATIC Route Control V7.1 and earlier
Siemens / SIMATIC Route Control V7.1 and earlier
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
|
SIMATIC Route Control V8.0
Siemens / SIMATIC Route Control V8.0
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
|
SIMATIC Route Control V8.1
Siemens / SIMATIC Route Control V8.1
|
vers:all/* |
No Fix Planned
Mitigation
Mitigation
|
|
|
SIMATIC Route Control V8.2
Siemens / SIMATIC Route Control V8.2
|
vers:all/* |
Vendor Fix
Mitigation
Mitigation
|
|
|
SIMATIC Route Control V9.0
Siemens / SIMATIC Route Control V9.0
|
< V9.0 Upd1 |
Vendor Fix
Mitigation
Mitigation
|
|
|
SIMATIC WinCC Runtime Professional V13
Siemens / SIMATIC WinCC Runtime Professional V13
|
< V13 SP2 Upd2 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
SIMATIC WinCC Runtime Professional V14
Siemens / SIMATIC WinCC Runtime Professional V14
|
< V14 SP1 Upd5 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
SIMATIC WinCC V7.2 and earlier
Siemens / SIMATIC WinCC V7.2 and earlier
|
< WinCC 7.2 Upd 15 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
SIMATIC WinCC V7.3
Siemens / SIMATIC WinCC V7.3
|
< WinCC 7.3 Upd 16 |
Vendor Fix
fix
Mitigation
Mitigation
|
|
|
SIMATIC WinCC V7.4
Siemens / SIMATIC WinCC V7.4
|
< V7.4 SP1 Upd 4 |
Vendor Fix
fix
Mitigation
Mitigation
|
{
"document": {
"acknowledgments": [
{
"names": [
"Independent researcher cdev1"
],
"summary": "coordinated disclosure"
},
{
"names": [
"Vladimir Dashchenko"
],
"organization": "Kaspersky Lab ICS CERT",
"summary": "reporting the vulnerability and coordination efforts"
}
],
"category": "Siemens Security Advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited.",
"tlp": {
"label": "WHITE"
}
},
"notes": [
{
"category": "summary",
"text": "A Denial-of-Service vulnerability has been identified in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC-Software.\n\nSiemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products where updates are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-348629: Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC Software - PDF Version",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf"
},
{
"category": "self",
"summary": "SSA-348629: Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC Software - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/ssa-348629.txt"
},
{
"category": "self",
"summary": "SSA-348629: Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC Software - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-348629.json"
}
],
"title": "SSA-348629: Denial-of-Service Vulnerability in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC Software",
"tracking": {
"current_release_date": "2022-04-12T00:00:00Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-348629",
"initial_release_date": "2018-03-27T00:00:00Z",
"revision_history": [
{
"date": "2018-03-27T00:00:00Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2018-04-18T00:00:00Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Updates for SIMATIC BATCH V8.0 and V8.1"
},
{
"date": "2018-06-12T00:00:00Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Updates for PCS 7 8.2"
},
{
"date": "2018-10-09T00:00:00Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Update for OpenPCS 7 V8.1 and SIMATIC WinCC Runtime Professional V13"
},
{
"date": "2018-11-13T00:00:00Z",
"legacy_version": "1.4",
"number": "5",
"summary": "Updated solution for SIMATIC BATCH V8.2, OpenPCS 7 V8.2, SIMATIC Route Control V8.2"
},
{
"date": "2018-12-11T00:00:00Z",
"legacy_version": "1.5",
"number": "6",
"summary": "Updated solution for SIMATIC NET PC-Software"
},
{
"date": "2018-12-13T00:00:00Z",
"legacy_version": "1.6",
"number": "7",
"summary": "Corrected update link for SIMATIC NET PC-Software"
},
{
"date": "2019-01-08T00:00:00Z",
"legacy_version": "1.7",
"number": "8",
"summary": "Updated patch links for WinCC 7.2 and 7.4"
},
{
"date": "2019-03-12T00:00:00Z",
"legacy_version": "1.8",
"number": "9",
"summary": "Corrected fixed version for WinCC 7.4"
},
{
"date": "2022-04-12T00:00:00Z",
"legacy_version": "1.9",
"number": "10",
"summary": "Added solution for SIMATIC NET PC Software V14 and clarified affected versions; Clarified no remediation planned"
}
],
"status": "interim",
"version": "10"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "OpenPCS 7 V7.1 and earlier",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "OpenPCS 7 V7.1 and earlier"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "OpenPCS 7 V8.0",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "OpenPCS 7 V8.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V8.1 Upd5",
"product": {
"name": "OpenPCS 7 V8.1",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "OpenPCS 7 V8.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "OpenPCS 7 V8.2",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "OpenPCS 7 V8.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V9.0 Upd1",
"product": {
"name": "OpenPCS 7 V9.0",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "OpenPCS 7 V9.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC BATCH V7.1 and earlier",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SIMATIC BATCH V7.1 and earlier"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V8.0 SP1 Upd21",
"product": {
"name": "SIMATIC BATCH V8.0",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SIMATIC BATCH V8.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V8.1 SP1 Upd16",
"product": {
"name": "SIMATIC BATCH V8.1",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "SIMATIC BATCH V8.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V8.2 Upd10",
"product": {
"name": "SIMATIC BATCH V8.2",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "SIMATIC BATCH V8.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V9.0 SP1",
"product": {
"name": "SIMATIC BATCH V9.0",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "SIMATIC BATCH V9.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V14 SP1 Update 14",
"product": {
"name": "SIMATIC NET PC Software V14",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "SIMATIC NET PC Software V14"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c 15 SP1",
"product": {
"name": "SIMATIC NET PC Software V15",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "SIMATIC NET PC Software V15"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS 7 V7.1 and earlier",
"product_id": "13"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS 7 V7.1 and earlier"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS 7 V8.0",
"product_id": "14"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS 7 V8.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS 7 V8.1",
"product_id": "15"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS 7 V8.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V8.2 SP1",
"product": {
"name": "SIMATIC PCS 7 V8.2",
"product_id": "16"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS 7 V8.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V9.0 SP1",
"product": {
"name": "SIMATIC PCS 7 V9.0",
"product_id": "17"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS 7 V9.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC Route Control V7.1 and earlier",
"product_id": "18"
}
}
],
"category": "product_name",
"name": "SIMATIC Route Control V7.1 and earlier"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC Route Control V8.0",
"product_id": "19"
}
}
],
"category": "product_name",
"name": "SIMATIC Route Control V8.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC Route Control V8.1",
"product_id": "20"
}
}
],
"category": "product_name",
"name": "SIMATIC Route Control V8.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC Route Control V8.2",
"product_id": "21"
}
}
],
"category": "product_name",
"name": "SIMATIC Route Control V8.2"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V9.0 Upd1",
"product": {
"name": "SIMATIC Route Control V9.0",
"product_id": "22"
}
}
],
"category": "product_name",
"name": "SIMATIC Route Control V9.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V13 SP2 Upd2",
"product": {
"name": "SIMATIC WinCC Runtime Professional V13",
"product_id": "23"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Professional V13"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V14 SP1 Upd5",
"product": {
"name": "SIMATIC WinCC Runtime Professional V14",
"product_id": "24"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC Runtime Professional V14"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c WinCC 7.2 Upd 15",
"product": {
"name": "SIMATIC WinCC V7.2 and earlier",
"product_id": "25"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC V7.2 and earlier"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c WinCC 7.3 Upd 16",
"product": {
"name": "SIMATIC WinCC V7.3",
"product_id": "26"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC V7.3"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003c V7.4 SP1 Upd 4",
"product": {
"name": "SIMATIC WinCC V7.4",
"product_id": "27"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC V7.4"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2018-4832",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality.\n\nPlease note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability.\n\nAt the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27"
]
},
"references": [
{
"summary": "CVE-2018-4832 - OpenPCS 7 V8.1",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109761055"
},
{
"summary": "CVE-2018-4832 - SIMATIC BATCH V8.0",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109756847"
},
{
"summary": "CVE-2018-4832 - SIMATIC BATCH V8.1",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109756846"
},
{
"summary": "CVE-2018-4832 - SIMATIC BATCH V8.2",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109757796"
},
{
"summary": "CVE-2018-4832 - SIMATIC NET PC Software V14",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109807351/"
},
{
"summary": "CVE-2018-4832 - SIMATIC NET PC Software V15",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109762690"
},
{
"summary": "CVE-2018-4832 - SIMATIC WinCC Runtime Professional V13",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109759753"
},
{
"summary": "CVE-2018-4832 - SIMATIC WinCC Runtime Professional V14",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109747394"
},
{
"summary": "CVE-2018-4832 - SIMATIC WinCC V7.2 and earlier",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109762887"
},
{
"summary": "CVE-2018-4832 - SIMATIC WinCC V7.3",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109756123"
},
{
"summary": "CVE-2018-4832 - SIMATIC WinCC V7.4",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109753031"
},
{
"summary": "CVE-2018-4832 Mitre 5.0 json",
"url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2018-4832.json"
}
],
"remediations": [
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2",
"6",
"13",
"14",
"15",
"18",
"19",
"20"
]
},
{
"category": "vendor_fix",
"details": "Update to OpenPCS 7 V8.1 Upd 5 or later version",
"product_ids": [
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109761055"
},
{
"category": "vendor_fix",
"details": "See remediation for PCS 7 V8.2",
"product_ids": [
"4",
"21"
]
},
{
"category": "vendor_fix",
"details": "See remediation for PCS 7 V9.0",
"product_ids": [
"5",
"10",
"22"
]
},
{
"category": "vendor_fix",
"details": "Update to SIMATIC BATCH V8.0 SP1 Upd21 or later version",
"product_ids": [
"7"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109756847"
},
{
"category": "vendor_fix",
"details": "Update to SIMATIC BATCH V8.1 SP1 Upd16 or later version",
"product_ids": [
"8"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109756846"
},
{
"category": "vendor_fix",
"details": "Update to SIMATIC BATCH V8.2 Upd10 or later version",
"product_ids": [
"9"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109757796"
},
{
"category": "vendor_fix",
"details": "Update to V14 SP1 Update 14 or later version",
"product_ids": [
"11"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109807351/"
},
{
"category": "vendor_fix",
"details": "Update to V15 SP1 or later version",
"product_ids": [
"12"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109762690"
},
{
"category": "vendor_fix",
"details": "Update to V8.2 SP1 or later version",
"product_ids": [
"16"
]
},
{
"category": "vendor_fix",
"details": "Update to V9.0 SP1 (Includes Open PCS 7 V9.0 Upd1, SIMATIC Batch V9.0 SP1, SIMATIC Route Control V9.0 Upd1 and SIMATIC WinCC V7.4 SP1 Upd4).",
"product_ids": [
"17"
]
},
{
"category": "vendor_fix",
"details": "Update to V13 SP2 Upd2 or later version",
"product_ids": [
"23"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109759753"
},
{
"category": "vendor_fix",
"details": "Update to V14 SP1 Upd5 or later version",
"product_ids": [
"24"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109747394"
},
{
"category": "vendor_fix",
"details": "Update to WinCC 7.2 Upd 15 or later version",
"product_ids": [
"25"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109762887"
},
{
"category": "vendor_fix",
"details": "Update to WinCC 7.3 Upd 16 or later version",
"product_ids": [
"26"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109756123"
},
{
"category": "vendor_fix",
"details": "Update to V7.4 SP1 Upd 4 or later version",
"product_ids": [
"27"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109753031"
},
{
"category": "mitigation",
"details": "Ensure that SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC PCS 7 stations communicate via encrypted channels (i.e. activate feature \u201cEncrypted Communication\u201d in SIMATIC WinCC V7.3 or newer and SIMATIC PCS 7 V8.1 or newer). Enabling \u201cEncrypted Communication\u201d completely mitigates the vulnerability.",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27"
]
},
{
"category": "mitigation",
"details": "Use VPN for protecting network communication between cells",
"product_ids": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"1",
"2",
"3",
"4",
"5",
"6",
"7",
"8",
"9",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27"
]
}
],
"title": "CVE-2018-4832"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.