SSA-693808
Vulnerability from csaf_siemens - Published: 2025-08-12 00:00 - Updated: 2026-11-10 00:00Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.
| Product | Identifier | Version | Remediation |
|---|---|---|---|
|
SIMATIC PCS neo V4.1
Siemens / SIMATIC PCS neo V4.1
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
|
SIMATIC WinCC V18 < V18 Update 6
Siemens / SIMATIC WinCC V18
|
vers:intdot/<18.0.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC WinCC V19 < V19 Update 4
Siemens / SIMATIC WinCC V19
|
vers:intdot/<19.0.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC WinCC V20 < V20 Update 4
Siemens / SIMATIC WinCC V20
|
vers:intdot/<20.0.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIMOCODE ES V17
Siemens / SIMOCODE ES V17
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SIMOCODE ES V18
Siemens / SIMOCODE ES V18
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SIMOCODE ES V19
Siemens / SIMOCODE ES V19
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SIMOCODE ES V20
Siemens / SIMOCODE ES V20
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SIMOTION SCOUT TIA V5.4 < V17 Update 9
Siemens / SIMOTION SCOUT TIA V5.4
|
vers:intdot/<17.0.9 |
Mitigation
Mitigation
Vendor Fix
|
|
|
SIMOTION SCOUT TIA V5.5 < V18 Update 6
Siemens / SIMOTION SCOUT TIA V5.5
|
vers:intdot/<18.0.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIMOTION SCOUT TIA V5.6 < V19 Update 4
Siemens / SIMOTION SCOUT TIA V5.6
|
vers:intdot/<19.0.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC PCS neo V5.0
Siemens / SIMATIC PCS neo V5.0
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
|
SIMOTION SCOUT TIA V5.7 < V20 Update 4
Siemens / SIMOTION SCOUT TIA V5.7
|
vers:intdot/<20.0.4 |
Mitigation
Mitigation
Vendor Fix
|
|
|
SINAMICS Startdrive V17
Siemens / SINAMICS Startdrive V17
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SINAMICS Startdrive V18
Siemens / SINAMICS Startdrive V18
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SINAMICS Startdrive V19
Siemens / SINAMICS Startdrive V19
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SINAMICS Startdrive V20
Siemens / SINAMICS Startdrive V20
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SIRIUS Safety ES V17 (TIA Portal)
Siemens / SIRIUS Safety ES V17 (TIA Portal)
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SIRIUS Safety ES V18 (TIA Portal)
Siemens / SIRIUS Safety ES V18 (TIA Portal)
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SIRIUS Safety ES V19 (TIA Portal)
Siemens / SIRIUS Safety ES V19 (TIA Portal)
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SIRIUS Safety ES V20 (TIA Portal)
Siemens / SIRIUS Safety ES V20 (TIA Portal)
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SIRIUS Soft Starter ES V17 (TIA Portal)
Siemens / SIRIUS Soft Starter ES V17 (TIA Portal)
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SIMATIC PCS neo V6.0 < V6.0 SP1 Update 1
Siemens / SIMATIC PCS neo V6.0
|
vers:intdot/<6.0.1.1 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIRIUS Soft Starter ES V18 (TIA Portal)
Siemens / SIRIUS Soft Starter ES V18 (TIA Portal)
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SIRIUS Soft Starter ES V19 (TIA Portal)
Siemens / SIRIUS Soft Starter ES V19 (TIA Portal)
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
SIRIUS Soft Starter ES V20 (TIA Portal)
Siemens / SIRIUS Soft Starter ES V20 (TIA Portal)
|
vers:all/* |
Mitigation
Mitigation
None Available
|
|
|
TIA Portal Cloud V17 < V6.0.0.0
Siemens / TIA Portal Cloud V17
|
vers:intdot/<6.0.0.0 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
TIA Portal Cloud V18 < V6.3.0.2
Siemens / TIA Portal Cloud V18
|
vers:intdot/<6.3.0.2 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
TIA Portal Cloud V19 < V5.2.1.1
Siemens / TIA Portal Cloud V19
|
vers:intdot/<5.2.1.1 |
Mitigation
Mitigation
Vendor Fix
|
|
|
TIA Portal Cloud V20 < V5.2.2.2
Siemens / TIA Portal Cloud V20
|
vers:intdot/<5.2.2.2 |
Mitigation
Mitigation
Vendor Fix
|
|
|
TIA Portal Test Suite V20 < V20 Update 4
Siemens / TIA Portal Test Suite V20
|
vers:intdot/<20.0.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC S7-PLCSIM V17
Siemens / SIMATIC S7-PLCSIM V17
|
vers:all/* |
Mitigation
Mitigation
No Fix Planned
|
|
|
SIMATIC STEP 7 V17 < V17 Update 9
Siemens / SIMATIC STEP 7 V17
|
vers:intdot/<17.0.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC STEP 7 V18 < V18 Update 6
Siemens / SIMATIC STEP 7 V18
|
vers:intdot/<18.0.6 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC STEP 7 V19 < V19 Update 4
Siemens / SIMATIC STEP 7 V19
|
vers:intdot/<19.0.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC STEP 7 V20 < V20 Update 4
Siemens / SIMATIC STEP 7 V20
|
vers:intdot/<20.0.4 |
Mitigation
Mitigation
Vendor Fix
fix
|
|
|
SIMATIC WinCC V17 < V17 Update 9
Siemens / SIMATIC WinCC V17
|
vers:intdot/<17.0.9 |
Mitigation
Mitigation
Vendor Fix
fix
|
{
"document": {
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)",
"tlp": {
"label": "WHITE"
}
},
"lang": "en",
"notes": [
{
"category": "summary",
"text": "Affected products do not properly restrict access permissions to a local Windows Named Pipe and do not properly sanitize user-controllable input sent to that Named Pipe. This could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges.\n\nSiemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.",
"title": "Summary"
},
{
"category": "general",
"text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"title": "General Recommendations"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "legal_disclaimer",
"text": "The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use.",
"title": "Terms of Use"
}
],
"publisher": {
"category": "vendor",
"contact_details": "productcert@siemens.com",
"name": "Siemens ProductCERT",
"namespace": "https://www.siemens.com"
},
"references": [
{
"category": "self",
"summary": "SSA-693808: Deserialization Vulnerability in Siemens Engineering Platforms - HTML Version",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-693808.html"
},
{
"category": "self",
"summary": "SSA-693808: Deserialization Vulnerability in Siemens Engineering Platforms - CSAF Version",
"url": "https://cert-portal.siemens.com/productcert/csaf/ssa-693808.json"
}
],
"title": "SSA-693808: Deserialization Vulnerability in Siemens Engineering Platforms",
"tracking": {
"current_release_date": "2026-11-10T00:00:00.000Z",
"generator": {
"engine": {
"name": "Siemens ProductCERT CSAF Generator",
"version": "1"
}
},
"id": "SSA-693808",
"initial_release_date": "2025-08-12T00:00:00.000Z",
"revision_history": [
{
"date": "2025-08-12T00:00:00.000Z",
"legacy_version": "1.0",
"number": "1",
"summary": "Publication Date"
},
{
"date": "2025-10-14T00:00:00.000Z",
"legacy_version": "1.1",
"number": "2",
"summary": "Added no fix expected for PCS neo V5.0, added fix for TIA Portal V20"
},
{
"date": "2025-12-09T00:00:00.000Z",
"legacy_version": "1.2",
"number": "3",
"summary": "Added fix for Totally Integrated Automation Portal (TIA Portal) V17"
},
{
"date": "2026-06-09T00:00:00.000Z",
"legacy_version": "1.3",
"number": "4",
"summary": "Added fix for SIMATIC PCS NEO V6.0"
},
{
"date": "2026-10-13T00:00:00.000Z",
"legacy_version": "1.4",
"number": "5",
"summary": "Added fix version for SIMATIC STEP 7 V18, TIA Portal Cloud V18 and SIMATIC WinCC V18"
},
{
"date": "2026-11-10T00:00:00.000Z",
"legacy_version": "1.5",
"number": "6",
"summary": "Added fix for TIA Portal Cloud V17, SIMOTION SCOUT TIA V5.4, SIMOTION SCOUT TIA V5.5, SIMOTION SCOUT TIA V5.7 and updated the fix version for SIMOTION SCOUT TIA V5.6"
}
],
"status": "interim",
"version": "6"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS neo V4.1",
"product_id": "1"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS neo V4.1"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC PCS neo V5.0",
"product_id": "2"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS neo V5.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.0.1.1",
"product": {
"name": "SIMATIC PCS neo V6.0 \u003c V6.0 SP1 Update 1",
"product_id": "3"
}
}
],
"category": "product_name",
"name": "SIMATIC PCS neo V6.0"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMATIC S7-PLCSIM V17",
"product_id": "4"
}
}
],
"category": "product_name",
"name": "SIMATIC S7-PLCSIM V17"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c17.0.9",
"product": {
"name": "SIMATIC STEP 7 V17 \u003c V17 Update 9",
"product_id": "5"
}
}
],
"category": "product_name",
"name": "SIMATIC STEP 7 V17"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c18.0.6",
"product": {
"name": "SIMATIC STEP 7 V18 \u003c V18 Update 6",
"product_id": "6"
}
}
],
"category": "product_name",
"name": "SIMATIC STEP 7 V18"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c19.0.4",
"product": {
"name": "SIMATIC STEP 7 V19 \u003c V19 Update 4",
"product_id": "7"
}
}
],
"category": "product_name",
"name": "SIMATIC STEP 7 V19"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c20.0.4",
"product": {
"name": "SIMATIC STEP 7 V20 \u003c V20 Update 4",
"product_id": "8"
}
}
],
"category": "product_name",
"name": "SIMATIC STEP 7 V20"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c17.0.9",
"product": {
"name": "SIMATIC WinCC V17 \u003c V17 Update 9",
"product_id": "9"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC V17"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c18.0.6",
"product": {
"name": "SIMATIC WinCC V18 \u003c V18 Update 6",
"product_id": "10"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC V18"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c19.0.4",
"product": {
"name": "SIMATIC WinCC V19 \u003c V19 Update 4",
"product_id": "11"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC V19"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c20.0.4",
"product": {
"name": "SIMATIC WinCC V20 \u003c V20 Update 4",
"product_id": "12"
}
}
],
"category": "product_name",
"name": "SIMATIC WinCC V20"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMOCODE ES V17",
"product_id": "13"
}
}
],
"category": "product_name",
"name": "SIMOCODE ES V17"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMOCODE ES V18",
"product_id": "14"
}
}
],
"category": "product_name",
"name": "SIMOCODE ES V18"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMOCODE ES V19",
"product_id": "15"
}
}
],
"category": "product_name",
"name": "SIMOCODE ES V19"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIMOCODE ES V20",
"product_id": "16"
}
}
],
"category": "product_name",
"name": "SIMOCODE ES V20"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c17.0.9",
"product": {
"name": "SIMOTION SCOUT TIA V5.4 \u003c V17 Update 9",
"product_id": "17"
}
}
],
"category": "product_name",
"name": "SIMOTION SCOUT TIA V5.4"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c18.0.6",
"product": {
"name": "SIMOTION SCOUT TIA V5.5 \u003c V18 Update 6",
"product_id": "18"
}
}
],
"category": "product_name",
"name": "SIMOTION SCOUT TIA V5.5"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c19.0.4",
"product": {
"name": "SIMOTION SCOUT TIA V5.6 \u003c V19 Update 4",
"product_id": "19"
}
}
],
"category": "product_name",
"name": "SIMOTION SCOUT TIA V5.6"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c20.0.4",
"product": {
"name": "SIMOTION SCOUT TIA V5.7 \u003c V20 Update 4",
"product_id": "20"
}
}
],
"category": "product_name",
"name": "SIMOTION SCOUT TIA V5.7"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS Startdrive V17",
"product_id": "21"
}
}
],
"category": "product_name",
"name": "SINAMICS Startdrive V17"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS Startdrive V18",
"product_id": "22"
}
}
],
"category": "product_name",
"name": "SINAMICS Startdrive V18"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS Startdrive V19",
"product_id": "23"
}
}
],
"category": "product_name",
"name": "SINAMICS Startdrive V19"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SINAMICS Startdrive V20",
"product_id": "24"
}
}
],
"category": "product_name",
"name": "SINAMICS Startdrive V20"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIRIUS Safety ES V17 (TIA Portal)",
"product_id": "25"
}
}
],
"category": "product_name",
"name": "SIRIUS Safety ES V17 (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIRIUS Safety ES V18 (TIA Portal)",
"product_id": "26"
}
}
],
"category": "product_name",
"name": "SIRIUS Safety ES V18 (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIRIUS Safety ES V19 (TIA Portal)",
"product_id": "27"
}
}
],
"category": "product_name",
"name": "SIRIUS Safety ES V19 (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIRIUS Safety ES V20 (TIA Portal)",
"product_id": "28"
}
}
],
"category": "product_name",
"name": "SIRIUS Safety ES V20 (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIRIUS Soft Starter ES V17 (TIA Portal)",
"product_id": "29"
}
}
],
"category": "product_name",
"name": "SIRIUS Soft Starter ES V17 (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIRIUS Soft Starter ES V18 (TIA Portal)",
"product_id": "30"
}
}
],
"category": "product_name",
"name": "SIRIUS Soft Starter ES V18 (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIRIUS Soft Starter ES V19 (TIA Portal)",
"product_id": "31"
}
}
],
"category": "product_name",
"name": "SIRIUS Soft Starter ES V19 (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:all/*",
"product": {
"name": "SIRIUS Soft Starter ES V20 (TIA Portal)",
"product_id": "32"
}
}
],
"category": "product_name",
"name": "SIRIUS Soft Starter ES V20 (TIA Portal)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.0.0.0",
"product": {
"name": "TIA Portal Cloud V17 \u003c V6.0.0.0",
"product_id": "33"
}
}
],
"category": "product_name",
"name": "TIA Portal Cloud V17"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c6.3.0.2",
"product": {
"name": "TIA Portal Cloud V18 \u003c V6.3.0.2",
"product_id": "34"
}
}
],
"category": "product_name",
"name": "TIA Portal Cloud V18"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.2.1.1",
"product": {
"name": "TIA Portal Cloud V19 \u003c V5.2.1.1",
"product_id": "35"
}
}
],
"category": "product_name",
"name": "TIA Portal Cloud V19"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c5.2.2.2",
"product": {
"name": "TIA Portal Cloud V20 \u003c V5.2.2.2",
"product_id": "36"
}
}
],
"category": "product_name",
"name": "TIA Portal Cloud V20"
},
{
"branches": [
{
"category": "product_version_range",
"name": "vers:intdot/\u003c20.0.4",
"product": {
"name": "TIA Portal Test Suite V20 \u003c V20 Update 4",
"product_id": "37"
}
}
],
"category": "product_name",
"name": "TIA Portal Test Suite V20"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2024-54678",
"cwe": {
"id": "CWE-502",
"name": "Deserialization of Untrusted Data"
},
"notes": [
{
"category": "description",
"text": "Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.",
"title": "CVE Description"
}
],
"product_status": {
"known_affected": [
"1",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"2",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"3",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
"remediations": [
{
"category": "mitigation",
"details": "On Desktop systems: Execute affected software on Windows hosts where only a single user is configured",
"product_ids": [
"1",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"2",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"3",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
{
"category": "mitigation",
"details": "On Server systems: Reduce the access on operating system level to administrators only",
"product_ids": [
"1",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"2",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"3",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"4",
"5",
"6",
"7",
"8",
"9"
]
},
{
"category": "no_fix_planned",
"details": "Currently no fix is planned",
"product_ids": [
"1",
"2",
"4"
]
},
{
"category": "none_available",
"details": "Currently no fix is available",
"product_ids": [
"13",
"14",
"15",
"16",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"30",
"31",
"32"
]
},
{
"category": "vendor_fix",
"details": "Update to V17 Update 9 or later version",
"product_ids": [
"5"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109784441/"
},
{
"category": "vendor_fix",
"details": "Update to V17 Update 9 or later version",
"product_ids": [
"9"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109784441/"
},
{
"category": "vendor_fix",
"details": "Update to V18 Update 6 or later version",
"product_ids": [
"6"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817218/"
},
{
"category": "vendor_fix",
"details": "Update to V18 Update 6 or later version",
"product_ids": [
"10"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109817218/"
},
{
"category": "vendor_fix",
"details": "Update to V18 Update 6 or later version",
"product_ids": [
"18"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109812772/"
},
{
"category": "vendor_fix",
"details": "Update to V19 Update 4 or later version",
"product_ids": [
"19"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109925643/"
},
{
"category": "vendor_fix",
"details": "Update to V19 Update 4 or later version",
"product_ids": [
"11"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109925643/"
},
{
"category": "vendor_fix",
"details": "Update to V19 Update 4 or later version",
"product_ids": [
"7"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109925643/"
},
{
"category": "vendor_fix",
"details": "Update to V20 Update 4 or later version",
"product_ids": [
"37"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109963851/"
},
{
"category": "vendor_fix",
"details": "Update to V20 Update 4 or later version",
"product_ids": [
"8"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109963851/"
},
{
"category": "vendor_fix",
"details": "Update to V20 Update 4 or later version",
"product_ids": [
"12"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109963851/"
},
{
"category": "vendor_fix",
"details": "Update to V6.0.0.0 or later version",
"product_ids": [
"33"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109784441/"
},
{
"category": "vendor_fix",
"details": "Update to V6.0 SP1 Update 1 or later version",
"product_ids": [
"3"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/110000357/"
},
{
"category": "vendor_fix",
"details": "Update to V6.3.0.2 or later version",
"product_ids": [
"34"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109794456/"
},
{
"category": "vendor_fix",
"details": "Update SIMOTION SCOUT TIA to V5.4 SP3\nhttps://support.industry.siemens.com/cs/ww/en/view/109801441/ and TIA Portal to V17 Update 9 or later version",
"product_ids": [
"17"
]
},
{
"category": "vendor_fix",
"details": "Fixed with V5.2.1.1, no user action required",
"product_ids": [
"35"
]
},
{
"category": "vendor_fix",
"details": "Update SIMOTION SCOUT TIA to V5.7 SP4 https://support.industry.siemens.com/cs/ww/en/view/110001596/ and TIA Portal to V20 Update 4 or later version",
"product_ids": [
"20"
]
},
{
"category": "vendor_fix",
"details": "Fixed with V5.2.2.2, no user action required",
"product_ids": [
"36"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 8.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"1",
"10",
"11",
"12",
"13",
"14",
"15",
"16",
"17",
"18",
"19",
"2",
"20",
"21",
"22",
"23",
"24",
"25",
"26",
"27",
"28",
"29",
"3",
"30",
"31",
"32",
"33",
"34",
"35",
"36",
"37",
"4",
"5",
"6",
"7",
"8",
"9"
]
}
],
"title": "CVE-2024-54678"
}
]
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation. The method is described in a publication.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.